Determination of ion-selective electrode characteristics by non-linear curve fitting

被引:54
作者
Kane, P [1 ]
Diamond, D [1 ]
机构
[1] DUBLIN CITY UNIV,SCH CHEM SCI,DUBLIN 9,IRELAND
关键词
curve-fitting; excel; ion-selective electrode; potassium; potentiometric selectivity coefficients; valinomycin;
D O I
10.1016/S0039-9140(97)00077-5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple practical method of determining potentiometric selectivity coefficients of ion-selective electrodes (ISEs) is described in which electrode characteristics (slope, potentiometric selectivity coefficients and cell constant) can be determined by fitting the experimental data obtained using the fixed interference (FI) method to an appropriate model by non-linear least-squares regression. The proposed method is simple to implement practically, and data processing can be easily achieved through use of the optimisation add-on, Solver, bundled with Microsoft Excel. The flexibility of the method is demonstrated by modelling the response of a valinomycin potassium-selective electrode with the Nikolskii-Eisenman equation and a recently proposed alternative to the Nikolskii-Eisenman equation for cases where the ionic charges on the primary and interfering ions are unequal. (C) 1997 Elsevier Science B.V.
引用
收藏
页码:1847 / 1858
页数:12
相关论文
共 30 条
[1]  
AMMANN D, 1983, ION SELECTIVE REV, V5, P38
[2]  
ANKER P, 1983, CLIN CHEM, V29, P1447
[3]  
[Anonymous], 1976, PURE APPL CHEM, V48, P127, DOI DOI 10.1351/PAC197648010127
[4]   SELECTIVITY OF POLYMER MEMBRANE-BASED ION-SELECTIVE ELECTRODES - SELF-CONSISTENT MODEL DESCRIBING THE POTENTIOMETRIC RESPONSE IN MIXED ION SOLUTIONS OF DIFFERENT CHARGE [J].
BAKKER, E ;
MERUVA, RK ;
PRETSCH, E ;
MEYERHOFF, ME .
ANALYTICAL CHEMISTRY, 1994, 66 (19) :3021-3030
[5]   Determination of improved selectivity coefficients of polymer membrane ion-selective electrodes by conditioning with a discriminated ion [J].
Bakker, E .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1996, 143 (04) :L83-L85
[6]   ELECTROANALYTICAL AND BIOCOMPATIBILITY STUDIES ON CARBOXYLATED POLY(VINYL CHLORIDE) MEMBRANES FOR MICROFABRICATED ARRAY SENSORS [J].
COSOFRET, VV ;
ERDOSY, M ;
BUCK, RP ;
KAO, WJ ;
ANDERSON, JM ;
LINDNER, E ;
NEUMAN, MR .
ANALYST, 1994, 119 (11) :2283-2292
[7]  
COVINGTON AK, 1979, ION SELECTIVE ELECTR, V1
[8]   Effect of membrane composition on the flow-injection response of an ion-selective electrode: A comparative study based on selectivity coefficients calculated using a data linearization technique [J].
Davey, DE ;
Mulcahy, DE ;
OConnell, GR .
ELECTROANALYSIS, 1996, 8 (03) :274-279
[9]   DETERMINATION AND APPLICATION OF ION-SELECTIVE ELECTRODE MODEL PARAMETERS USING FLOW-INJECTION AND SIMPLEX OPTIMIZATION [J].
DEVITERI, FJS ;
DIAMOND, D .
ANALYST, 1994, 119 (05) :749-758
[10]   ROBUST ESTIMATION OF SELECTIVITY COEFFICIENTS USING MULTIVARIATE CALIBRATION OF ION-SELECTIVE ELECTRODE ARRAYS [J].
DIAMOND, D ;
FORSTER, RJ .
ANALYTICA CHIMICA ACTA, 1993, 276 (01) :75-86