Quantification of atelectases in artificial respiration: Spiral-CT versus dynamic single-slice CT

被引:15
作者
Bletz, C
Markstaller, K
Karmrodt, J
Herweling, A
Melvan, M
Goetz, R
Stepniak, A
Eberle, B
Kauczor, HU
Heussel, CP
Thelen, M
机构
[1] Univ Mainz, Klin & Poliklin Radiol, D-55131 Mainz, Germany
[2] Univ Mainz, Anasthesiol Klin, D-6500 Mainz, Germany
[3] Univ Bern, Inst Anasthesiol, Bern, Switzerland
[4] Univ Bern, Inselspital, Bern, Switzerland
[5] Deutsch Krebsforschungszentrum, Abt Radiol, D-6900 Heidelberg, Germany
来源
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN | 2004年 / 176卷 / 03期
关键词
chest CT; dynamic computed tomography; density; volumetry; pig;
D O I
10.1055/s-2004-812889
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Dynamic CT (dCT) allows visualization and quantification of ventilated lung and atelectases with high temporal resolution during continuous ventilation. This study compares a quantitative image analysis in a subcarinal single slice dCT series versus a whole lung spiral-CT, in order to analyze, whether the distribution of atelectasis of a single dCT series is representative for the whole lung. Materials and Methods: dCT in sliding windows technique (slice thickness 1 mm, temporal increment 100 ms) was performed in 8 healthy pigs 3 cm caudal to the carina during continuous mechanical ventilation. Subsequently, a spiral-CT of the whole lung (slice thickness 2 mm; pitch 1.5; increment 2 mm) was acquired during inspiratory breath hold (airway pressure 20 mbar). Lung segmentation and planimetry of predefined density ranges were achieved using a dedicated software tool in both data-sets. Thus, the fractions of the following functional lung compartments were averaged over time: hyperinflated lung (-1024 to -910 HE), normal ventilated lung -900 to -300 HE) and atelectasis (-300 to +200 HE). Results: Quantitative analysis of dCF-series during continuous respiration correlated with the density analysis in spiral-CT as follows: hyperinflated lung r = 0.56; normal ventilated lung r = 0.83 and atelectases r = 0.84. Analysis of spiral-CT showed the following distribution of functional lung compartments: hyperinflated lung 3.1% normal ventilated lung 77.9% and atelectasis 19.0%. In dCT, hyperinflated lung represented 6.4%, normal ventilated lung 65.2% and atelectasis 28.4% of total the lung area. Conclusion: The results of our study demonstrate that dCT allows monitoring of atelectasis formation in response to different ventilatory strategies. However, a deviation between dCT and spiral-CT has to be taken into account. In subcarinal dCT series, hyperinflated lung areas and atelectases were overestimated due to a craniocaudal gradient of atelectases, whereas normal ventilated lung was underestimated.
引用
收藏
页码:409 / 416
页数:8
相关论文
共 30 条
[11]   Alveolar collapse and closure of airways: regular effects of anaesthesia [J].
Hedenstierna, G .
CLINICAL PHYSIOLOGY AND FUNCTIONAL IMAGING, 2003, 23 (03) :123-129
[12]   Diagnosis of tracheal instability: Inspiratory and expiratory spiral CT and cine CT. [J].
Heussel, CP ;
Hafner, B ;
Lill, J ;
Thelen, M ;
Kauczor, HU .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2000, 172 (02) :115-121
[13]   Paired inspiratory/expiratory spiral CT and continuous respiration cine CT in the diagnosis of tracheal instability [J].
Heussel, CP ;
Hafner, B ;
Lill, J ;
Schreiber, W ;
Thelen, M ;
Kauczor, HU .
EUROPEAN RADIOLOGY, 2001, 11 (06) :982-989
[14]   Basics and technique of spiral CT [J].
Kalender, WA .
RADIOLOGE, 1999, 39 (09) :809-819
[15]   CT lung densitometry: Dependence of CT number histograms on sample volume and consequences for scan protocol comparability [J].
Kemerink, GJ ;
Kruize, HH ;
Lamers, RJS ;
vanEngelshoven, JMA .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1997, 21 (06) :948-954
[16]   Assessment of PEEP-induced reopening of collapsed lung regions in acute lung injury: are one or three CT sections representative of the entire lung? [J].
Lu, Q ;
Malbouisson, LM ;
Mourgeon, E ;
Goldstein, I ;
Coriat, P ;
Rouby, JJ .
INTENSIVE CARE MEDICINE, 2001, 27 (09) :1504-1510
[17]   CT-ASSESSMENT OF DEPENDENT LUNG DENSITIES IN MAN DURING GENERAL-ANESTHESIA [J].
LUNDQUIST, H ;
HEDENSTIERNA, G ;
STRANDBERG, A ;
TOKICS, L ;
BRISMAR, B .
ACTA RADIOLOGICA, 1995, 36 (06) :626-632
[18]   Computed tomography assessment of positive end-expiratory pressure-induced alveolar recruitment in patients with acute respiratory distress syndrome [J].
Malbouisson, LM ;
Muller, JC ;
Constantin, JM ;
Lu, Q ;
Puybasset, L ;
Rouby, JJ .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2001, 163 (06) :1444-1450
[19]   Dynamic multiscan CT during artificial respiration: Comparison of different density ranges in healthy lungs and in a lavage ARDS model. [J].
Markstaller, K ;
Kauczor, HU ;
Eberle, B ;
Weiler, N ;
Siebertz, D ;
Birkenkamp, K ;
Heinrichs, W ;
Thelen, M .
ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1999, 170 (06) :575-580
[20]   Temporal dynamics of lung aeration determined by dynamic CT in a porcine model of ARDS [J].
Markstaller, K ;
Eberle, B ;
Kauczor, HU ;
Scholz, A ;
Bink, A ;
Thelen, M ;
Heinrichs, W ;
Weiler, N .