The minimum number of target lesions that need to be measured to be representative of the total number of target lesions (according to RECIST)

被引:15
作者
Darkeh, M. H. S. E. [1 ,2 ]
Suzuki, C. [2 ,3 ,4 ]
Torkzad, M. R. [1 ,5 ]
机构
[1] Karolinska Inst, Inst Mol Med & Surg, Stockholm, Sweden
[2] Karolinska Univ Hosp Solna, Dept Diagnost Radiol, Stockholm, Sweden
[3] Natl Canc Ctr E, Chiba, Japan
[4] Keio Univ, Sch Med, Dept Radiol, Tokyo, Japan
[5] Univ Uppsala Hosp, Dept Radiol, Uppsala, Sweden
关键词
AUTOMATED CT VOLUMETRY; SOLID TUMORS; PULMONARY METASTASES; RESPONSE EVALUATION; THERAPY RESPONSE; END-POINTS; CRITERIA; LIMITATIONS;
D O I
10.1259/bjr/72829563
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
100231 [临床病理学]; 100902 [航空航天医学];
摘要
Response evaluation criteria in solid tumours (RECIST) were introduced as a means to classify tumour response with no definition of the minimum number of lesions. This study was conducted in order to evaluate discrepancies between full assessments based on either all target lesions or fewer lesions. RECIST evaluation was performed on separate occasions based on between one and seven of the target lesions, with simultaneous assessment of non-target lesions. 99 patients were included. 38 patients demonstrated progressive disease, in 61% of whom it was a result of the appearance of new lesions or unequivocal progress in non-target lesions. 32 patients showed stable disease, with 8 having results that differed when 1-3 target lesions were measured. 22 cases were considered as having partial regression, with only 1 case; differing when performing 1-3 target lesion assessments. Seven cases demonstrated complete response. The number of discordant cases increased gradually from measuring three lesions to one target lesion. The average number of available target lesions among those with discrepancies was 7.1, which was significantly higher than those demonstrating concordance (4.1 lesions; p < 0.05). In conclusion, measuring fewer than four target lesions might cause discrepancies when more than five target lesions are present.
引用
收藏
页码:681 / 686
页数:6
相关论文
共 18 条
[1]
Development of adapted RECIST criteria to assess response in lymphoma and their comparison to the International Workshop Criteria [J].
Assouline, Sarit ;
Meyer, Ralph M. ;
Infante-Rivard, Claire ;
Connors, Joseph M. ;
Belch, Andrew ;
Crump, Michael ;
Kouroukis, C. Tom ;
Eisenhauer, Elizabeth .
LEUKEMIA & LYMPHOMA, 2007, 48 (03) :513-520
[2]
Limitations with the response evaluation criteria in solid tumors (RECIST) guidance in disseminated pediatric malignancy [J].
Barnacle, AM ;
McHugh, K .
PEDIATRIC BLOOD & CANCER, 2006, 46 (02) :127-134
[3]
Modified RECIST criteria for assessment of response in malignant pleural mesothelioma [J].
Byrne, MJ ;
Nowak, AK .
ANNALS OF ONCOLOGY, 2004, 15 (02) :257-260
[4]
Response evaluation: beyond RECIST [J].
Eisenhauer, E. A. .
ANNALS OF ONCOLOGY, 2007, 18 :29-32
[5]
Volumetric evaluation of therapy response in patients with lung metastases. Preliminary results with a computer system (CAD) and comparison with unidimensional measurements [J].
Fraioli F. ;
Bertoletti L. ;
Napoli A. ;
Calabrese F.A. ;
Masciangelo R. ;
Cortesi E. ;
Catalane C. ;
Passariello R. .
La radiologia medica, 2006, 111 (3) :365-375
[6]
Evaluation of the response to treatment of solid tumours - a consensus statement of the International Cancer Imaging Society [J].
Husband, JE ;
Schwartz, LH ;
Spencer, J ;
Ollivier, L ;
King, DM ;
Johnson, R ;
Reznek, R .
BRITISH JOURNAL OF CANCER, 2004, 90 (12) :2256-2260
[7]
Measures of response: RECIST, WHO, and new alternatives [J].
Jaffe, C. Carl .
JOURNAL OF CLINICAL ONCOLOGY, 2006, 24 (20) :3245-3251
[8]
Inadequacy of manual measurements compared to automated CT volumetry in assessment of treatment response of pulmonary metastases using RECIST criteria [J].
Marten, K ;
Auer, F ;
Schmidt, S ;
Kohl, G ;
Rummeny, EJ ;
Engelke, C .
EUROPEAN RADIOLOGY, 2006, 16 (04) :781-790
[9]
Automated CT volumetry of pulmonary metastases: the effect of a reduced growth threshold and target lesion number on the reliability of therapy response assessment using RECIST criteria [J].
Marten, Katharina ;
Auer, Florian ;
Schmidt, Stefan ;
Rummeny, Ernst J. ;
Engelke, Christoph .
EUROPEAN RADIOLOGY, 2007, 17 (10) :2561-2571
[10]
Measuring response in a post-RECIST world: from black and white to shades of grey [J].
Michaelis, LC ;
Ratain, MJ .
NATURE REVIEWS CANCER, 2006, 6 (05) :409-414