The effects of developer age on diagnostic accuracy: a study using assessment of endodontic file length

被引:9
作者
Syriopoulos, K [1 ]
Sanderink, GCH [1 ]
Velders, XL [1 ]
van Ginkel, FC [1 ]
van der Stelt, PF [1 ]
机构
[1] Acad Ctr Dent Amsterdam, Dept Oral Radiol, NL-1066 EA Amsterdam, Netherlands
关键词
radiography; dental; X-ray film; ROC curve; perception;
D O I
10.1038/sj.dmfr.4600464
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: To examine the effects of developer age on image quality. Methods: Endodontic files, size 10 and 15, were placed in upper and lower molars and premolars up to the root apex or 1.5 mm short. A series of radiographs were made with each of three film types: Dentus M2 (Agfa-Gevaert, Mortsel, Belgium). Ektaspeed Plus and Ultra-speed (Kodak Eastman Co, Rochester, USA). The films were processed bi-weekly using the same Agfa chemicals (Heraeus Kulzer, Dormagen, Germany) over a 6-week period. An additional set of Dentus M2 films was processed using Periomat chemicals (Durr Dental, Bietigheim-Bissingen, Germany). The films were viewed by eight dentists who rated the position of the tip of the file using a 5-point confidence scale. ROC data were analysed by means of analysis of variance. A(z) value was the dependent variable, whereas observer age group was entered as between subject factor. The null hypothesis was rejected when P<0.05. Results: The diagnostic accuracies of the three films were comparable during the first 4 weeks. In the sixth week Ultra-speed was significantly better than the other two films (P=0.046). The Periomat chemicals showed significantly greater consistency than the Agfa chemicals (P=0.004). Developer exhaustion significantly affected the performance of the older observers (P=0.008), especially when Agfa chemicals and file size 10 were used. Conclusion: Agfa chemicals older than 4 weeks significantly affect the assessment of endodontic file length. In earlier stages there are no significant differences between the three films tested. Dentus M2 and Ektaspeed Plus films should be used as they require lower exposures.
引用
收藏
页码:311 / 315
页数:5
相关论文
共 19 条
[1]   An evaluation of Ektaspeed Plus film versus Ultraspeed film for endodontic working length determination [J].
Brown, R ;
Hadley, JN ;
Chambers, DW .
JOURNAL OF ENDODONTICS, 1998, 24 (01) :54-56
[2]   CONTRAST SENSITIVITY DECLINE WITH AGING - A NEURAL OR OPTICAL PHENOMENON [J].
ELLIOTT, DB .
OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 1987, 7 (04) :415-419
[3]  
GREENE HA, 1987, AM J OPTOM PHYS OPT, V64, P749
[4]  
Hennelly ML, 1998, OPHTHAL PHYSL OPT, V18, P197, DOI 10.1016/S0275-5408(97)00077-X
[5]   In vitro comparison of Kodak Ultra-speed, Ektaspeed, and Ektaspeed Plus, and Agfa M2 comfort dental x-ray films for the detection of caries [J].
Hintze, H ;
Christoffersen, L ;
Wenzel, A .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1996, 81 (02) :240-244
[6]   The efficacy of caries detection using three intraoral films under different processing conditions [J].
Ludlow, JB ;
Platin, E ;
Delano, EO ;
Clifton, L .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 1997, 128 (10) :1401-1408
[8]   THE USE OF E-SPEED FILM FOR ROOT-CANAL LENGTH DETERMINATION [J].
POWELLCULLINGFORD, AW ;
FORD, TRP .
INTERNATIONAL ENDODONTIC JOURNAL, 1993, 26 (05) :268-272
[9]   EFFECT OF AGE ON CONTRAST SENSITIVITY FUNCTION - UNIOCULAR AND BINOCULAR FINDINGS [J].
ROSS, JE ;
CLARKE, DD ;
BRON, AJ .
BRITISH JOURNAL OF OPHTHALMOLOGY, 1985, 69 (01) :51-56
[10]   IMAGE QUALITY OF DIRECT DIGITAL INTRAORAL X-RAY SENSORS IN ASSESSING ROOT-CANAL LENGTH - THE RADIOVISIOGRAPHY, VISUALIX VIXA, SENS-A-RAY, AND FLASH DENT SYSTEMS COMPARED WITH EKTASPEED FILMS [J].
SANDERINK, GCH ;
HUISKENS, R ;
VANDERSTELT, PF ;
WELANDER, US ;
STHEEMAN, SE .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1994, 78 (01) :125-132