One-step immunostrip test for the simultaneous detection of free and total prostate specific antigen in serum

被引:64
作者
Fernández-Sánchez, C
McNeil, CJ
Rawson, K
Nilsson, O
Leung, HY
Gnanapragasam, V
机构
[1] Newcastle Univ, Sch Med, Sch Clin & Lab Sci, Newcastle Upon Tyne NE2 4HH, Tyne & Wear, England
[2] Cambridge Life Sci Ltd, Cambridge CB7 4EX, England
[3] CanAg Diagnost AB, SE-41455 Gothenburg, Sweden
[4] Newcastle Univ, Sch Med, Sch Surg & Reprod Sci, Newcastle Upon Tyne NE2 4HH, Tyne & Wear, England
关键词
lateral flow assay; immunostrip; free and total prostate specific antigen; colloidal gold; serum;
D O I
10.1016/j.jim.2005.08.014
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The development of a one-step lateral flow immunoassay on a strip format for the rapid and reliable simultaneous detection of serum levels of free and total prostate specific antigen (f-PSA and t-PSA) and estimation of f-PSA to t-PSA ratio (f/t-PSA) is reported. The f/t-PSA ratio has shown to be more specific for the correct diagnosis of prostate cancer than t-PSA alone, especially in the so-called diagnostic grey zone of 4-10 mu g/l t-PSA. The performance of the system described relied on non-competitive immunoassay protocols. Herein, f-PSA and t-PSA were sandwiched between anti-f-PSA and anti-t-PSA monoclonal antibodies immobilised on the strip and a colloidal gold anti-PSA antibody tracer. In the presence of PSA in the sample, the tracer accumulated on the strip results in the appearance of specific pink colour lines. The colour intensity of these lines was found to be directly proportional to the PSA concentration and a semi-quantitative estimation could be carried out visually. Quantitative analysis was also possible by densitometry. Using PSA standards prepared in female serum, the strip could be calibrated up to a concentration of 60 mu g/l for both PSA species, with an assay time of less than 20 min. The estimated detection limit was 1 mu g/l in all cases. The immunostrip showed good storage stability for at least 2 months and the reproducibility was always between 12% and 17%. Fifty-one male serum samples were analysed with the strip and results compared with values obtained by two different commercial immunoassays taken as reference methods. The study yielded acceptable correlation and agreement. An estimation of the sensitivity and specificity demonstrated the strip validity as a potential front-line device for the early detection of prostate cancer and differentiation of benign prostatic anomalies. Small plastic cartridges incorporating the immunostrip and a small blister containing washing solution that helps remove unbound species from the strip were envisaged in order to avoid false positive readings and decrease background signals, thereby leading to better sensitivity and detection limits.(c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:1 / 12
页数:12
相关论文
共 35 条
  • [1] Measuring agreement in method comparison studies
    Bland, JM
    Altman, DG
    [J]. STATISTICAL METHODS IN MEDICAL RESEARCH, 1999, 8 (02) : 135 - 160
  • [2] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [3] Brawer MK, 2000, SEMIN SURG ONCOL, V18, P29, DOI 10.1002/(SICI)1098-2388(200001/02)18:1<29::AID-SSU5>3.0.CO
  • [4] 2-Y
  • [5] Simple dipstick assay for semi-quantitative detection of neopterin in sera
    Bührer-Sekula, S
    Hamerlinck, FFV
    Out, TA
    Bordewijk, LG
    Klatser, PR
    [J]. JOURNAL OF IMMUNOLOGICAL METHODS, 2000, 238 (1-2) : 55 - 58
  • [6] Use of the percentage of free prostate-specific antigen to enhance differentiation of prostate cancer from benign prostatic disease - A prospective multicenter clinical trial
    Catalona, WJ
    Partin, AW
    Slawin, KM
    Brawer, MK
    Flanigan, RC
    Patel, A
    Richie, JP
    deKernion, JB
    Walsh, PC
    Scardino, PT
    Lange, PH
    Subong, ENP
    Parson, RE
    Gasior, GH
    Loveland, KG
    Southwick, PC
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1998, 279 (19): : 1542 - 1547
  • [7] CATALONA WJ, 1995, JAMA-J AM MED ASSOC, V274, P1214
  • [8] Development of a quantitative lateral-flow assay for rapid detection of fatty acid-binding protein
    Chan, CPY
    Sum, KW
    Cheung, KY
    Glatz, JFC
    Sanderson, JE
    Hempel, A
    Lehmann, M
    Renneberg, I
    Renneberg, R
    [J]. JOURNAL OF IMMUNOLOGICAL METHODS, 2003, 279 (1-2) : 91 - 100
  • [9] Cheli CD, 1998, CLIN CHEM, V44, P1551
  • [10] Disposable noncompetitive immunosensor for free and total prostate-specific antigen based on capacitance measurement
    Fernández-Sánchez, C
    McNeil, CJ
    Rawson, K
    Nilsson, O
    [J]. ANALYTICAL CHEMISTRY, 2004, 76 (19) : 5649 - 5656