Disposable noncompetitive immunosensor for free and total prostate-specific antigen based on capacitance measurement

被引:103
作者
Fernández-Sánchez, C
McNeil, CJ
Rawson, K
Nilsson, O
机构
[1] Newcastle Univ, Sch Med, Sch Clin & Lab Sci, Inst Nanoscale Sci & Technol, Newcastle Upon Tyne NE2 4HH, Tyne & Wear, England
[2] Cambridge Life Sci Ltd, Ely CB7 4EX, Cambs, England
[3] CanAg Diagnost AB, SE-41455 Gothenburg, Sweden
关键词
D O I
10.1021/ac0494937
中图分类号
O65 [分析化学];
学科分类号
070302 [分析化学]; 081704 [应用化学];
摘要
This work reports on the successful integration of a one-step lateral flow immunoassay format and impedance detection of the specific affinity event using an electrochemical transducer coated with a pH-sensitive polymer layer. This approach was particularly applied to the development of a rapid single-use immunosensor for the sensitive detection of free and total prostate-specific antigen (f-PSA, t-PSA) tumor marker. Strips of nitrocellulose membrane were coated with appropriate antibodies to f-PSA and t-PSA and used as solid supports for the performance of noncompetitive immunoassays where PSA was allowed to react with both immobilized anti-PSA antibody and anti-PSA urease enzyme conjugate for less than 1 min. An additional piece within the device consisting of a storage blister filled with a urea solution allowed the rapid washing of unbound species from the membrane strips and simultaneous urea hydrolysis catalyzed by the bound urease conjugate in an automatic fashion. The hydrolysis of urea increased the pH of the reaction media, which in turn induced a breakdown of the polymer layer on the transducer and a consequent measurable change in capacitance of the system. Ibis was easily recorded at a given frequency over a 30-min period. Overall, we describe a one-step immunosensor prototype that exhibits enough sensitivity to detect both forms of PSA at concentration levels down to 3 ng/mL. With the possibility of being portable and considering its ease of use, robustness, and simplicity, this device has great potential as a tool for the screening and early detection of prostate cancer.
引用
收藏
页码:5649 / 5656
页数:8
相关论文
共 28 条
[1]
Application of electrochemical impedance spectroscopy to study the degradation of polymer-coated metals [J].
Amirudin, A ;
Thierry, D .
PROGRESS IN ORGANIC COATINGS, 1995, 26 (01) :1-28
[2]
Development of a new immunosensor for pesticide detection: a disposable system with liposome-enhancement and amperometric detection [J].
Baumner, AJ ;
Schmid, RD .
BIOSENSORS & BIOELECTRONICS, 1998, 13 (05) :519-529
[3]
Possibility of improving the acceptance rate of early detection testing for prostate cancer with a one-step test for prostate-specific antigen in whole blood [J].
Berg, W ;
Linder, C ;
Eschholz, G ;
Link, S ;
Schubert, J .
UROLOGIA INTERNATIONALIS, 1999, 63 (02) :102-106
[4]
Simple dipstick assay for semi-quantitative detection of neopterin in sera [J].
Bührer-Sekula, S ;
Hamerlinck, FFV ;
Out, TA ;
Bordewijk, LG ;
Klatser, PR .
JOURNAL OF IMMUNOLOGICAL METHODS, 2000, 238 (1-2) :55-58
[5]
SHOULD MEDICARE PROVIDE REIMBURSEMENT FOR PROSTATE-SPECIFIC ANTIGEN TESTING FOR EARLY DETECTION OF PROSTATE-CANCER .2. EARLY DETECTION STRATEGIES [J].
COLEY, CM ;
BARRY, MJ ;
FLEMING, C ;
WASSON, JH ;
FAHS, MC ;
OESTERLING, JE .
UROLOGY, 1995, 46 (02) :125-141
[6]
Fernández-Sánchez C, 2004, ELECTROCHEM COMMUN, V6, P138, DOI [10.1016/j.elecom.2003.11.002, 10.1016/j.elecom.11.002]
[7]
Groche D, 1999, ANTICANCER RES, V19, P2767
[8]
Prostate specific antigen and human glandular kallikrein 2 in early detection of prostate cancer [J].
Karazanashvili, G ;
Abrahamsson, PA .
JOURNAL OF UROLOGY, 2003, 169 (02) :445-457
[9]
Conductimetric membrane strip immunosensor with polyaniline-bound gold colloids as signal generator [J].
Kim, JH ;
Cho, JH ;
Cha, GS ;
Lee, CW ;
Kim, HB ;
Paek, SH .
BIOSENSORS & BIOELECTRONICS, 2000, 14 (12) :907-915
[10]
Behaviour of pH sensitive polymers on metal electrodes [J].
Krause, S ;
McNeil, CJ ;
Armstrong, RD ;
Ho, WO .
JOURNAL OF APPLIED ELECTROCHEMISTRY, 1997, 27 (03) :291-298