Inter-fraction bladder filling variations and time trends for cervical cancer patients assessed with a portable 3-dimensional ultrasound bladder scanner

被引:115
作者
Ahmad, Rozilawati [1 ]
Hoogeman, Mischa S. [1 ]
Quint, Sandra [1 ]
Mens, Jan Willem [1 ]
de Pree, Ilse [1 ]
Heijmen, Ben J. M. [1 ]
机构
[1] Erasmus MC, Dr Daniel Den Hoed Canc Ctr, Dept Radiat Oncol, NL-3075 EA Rotterdam, Netherlands
关键词
Bladder volume; Cervix cancer; Patient positioning; 3D portable Ultrasound; Radiotherapy; IGRT;
D O I
10.1016/j.radonc.2008.07.005
中图分类号
R73 [肿瘤学];
学科分类号
100214 [肿瘤学];
摘要
Background and Purpose: For cervical cancer patients, bladder filling variations may result in inadequate EBRT target coverage, unless large safety margins are used. For a group of patients who received full bladder instructions, interfraction variations and time trends in bladder volume were quantified, and a 3D ultrasound (US) scanner was tested for on-line bladder volume measurements. Methods and materials: For 24 patients, the bladder volume was measured with US at the time of the planning CT scan, and twice weekly during the course of RT. Comparisons of US with planning CT were used to assess the bladder scanner accuracy. Patients were treated in prone on a belly board, EPID images were acquired to correlate set-up errors with bladder filling variations. Results: Measured US and CT bladder volumes were strongly correlated (R = 0.97, slope 1.1 +/- 0.1).The population mean bladder volume at planning of 378 +/- 209 ml (1 SD) reduced to 109 +/- 88 ml (1 SD) in week 6, a reduction by 71% (average reduction 46 ml/week), revealing a large inter-fraction time trend. Intra-patient variation in bladder volume during RT was 168 mt (1 SD) (range 70-266 ml). Rotation around the LR axis was significantly correlated with bladder volume changes. Conclusions: Despite a full bladder instruction, bladder volumes reduced dramatically during treatment, implying large time trends in target position of these patients. The portable US scanner provides a quick and reliable measurement of the bladder volume, which might assist future online treatment adaptation. (c) 2008 Elsevier Ireland Ltd. All rights reserved. Radiotherapy and Oncology 89 (2008) 172-179.
引用
收藏
页码:172 / 179
页数:8
相关论文
共 29 条
[1]
THE VARIATION OF SMALL-BOWEL VOLUME WITHIN THE PELVIS BEFORE AND DURING ADJUVANT RADIATION FOR RECTAL-CANCER [J].
BRIERLEY, JD ;
CUMMINGS, BJ ;
WONG, CS ;
MCLEAN, M ;
CASHELL, A ;
MANTER, S .
RADIOTHERAPY AND ONCOLOGY, 1994, 31 (02) :110-116
[2]
Impact of the filling status of the bladder and rectum on their integral dose distribution and the movement of the uterus in the treatment planning of gynaecological cancer [J].
Buchali, A ;
Koswig, S ;
Dinges, S ;
Rosenthal, P ;
Salk, J ;
Lackner, G ;
Böhmer, D ;
Schlenger, L ;
Budach, V .
RADIOTHERAPY AND ONCOLOGY, 1999, 52 (01) :29-34
[3]
Accuracy of bladder volume determinations by ultrasonography: Are they accurate over entire bladder volume range? [J].
Byun, SS ;
Kim, HH ;
Lee, E ;
Paick, JS ;
Kamg, W ;
Oh, SJ .
UROLOGY, 2003, 62 (04) :656-660
[4]
THE ACCURACY OF PORTABLE ULTRASOUND SCANNING IN THE MEASUREMENT OF RESIDUAL URINE VOLUME [J].
COOMBES, GM ;
MILLARD, RJ .
JOURNAL OF UROLOGY, 1994, 152 (06) :2083-2085
[5]
Surgery and postoperative radiotherapy versus surgery alone for patients with stage-1 endometrial carcinoma:: multicentre randomised trial [J].
Creutzberg, CL ;
van Putten, WLJ ;
Koper, PCM ;
Lybeert, MLM ;
Jobsen, JJ ;
Wárlám-Rodenhuis, CC ;
De Winter, KAJ ;
Lutgens, LCHW ;
van den Bergh, ACM ;
van de Steen-Banasik, E ;
Beerman, H ;
van Lent, M .
LANCET, 2000, 355 (9213) :1404-1411
[6]
Application of the no action level (NAL) protocol to correct for prostate motion based on electronic portal imaging of implanted markers [J].
De Boer, HCJ ;
Van Os, MJH ;
Jansen, PP ;
Heumen, BJM .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 61 (04) :969-983
[7]
Characterization of a high-elbow, fluoroscopic electronic portal imaging device for portal dosimetry [J].
de Boer, JCJ ;
Heijmen, BJM ;
Pasma, KL ;
Visser, AG .
PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (01) :197-216
[8]
Variability of bladder filling in patients receiving radical radiotherapy to the prostate [J].
Doherty, Una M. ;
McNair, Helen A. ;
Norman, Andrew R. ;
Miles, Elizabeth ;
Hooper, Simon ;
Davies, Mark ;
Lincoln, Naomi ;
Balyckyi, Jan ;
Childs, Peter ;
Dearnaley, David P. ;
Huddart, Robert A. .
RADIOTHERAPY AND ONCOLOGY, 2006, 79 (03) :335-340
[9]
Pelvic irradiation with concurrent chemotherapy versus pelvic and para-aortic irradiation for high-risk cervical cancer: An update of radiation therapy oncology group trial (RTOG) 90-01 [J].
Eifel, PJ ;
Winter, K ;
Morris, M ;
Levenback, C ;
Grigsby, PW ;
Cooper, J ;
Rotman, M ;
Gershenson, D ;
Mutch, DG .
JOURNAL OF CLINICAL ONCOLOGY, 2004, 22 (05) :872-880
[10]
Rectal and bladder motion during conformal radiotherapy after radical prostatectomy [J].
Fiorino, C ;
Foppiano, F ;
Franzone, P ;
Broggi, S ;
Castellone, P ;
Marcenaro, M ;
Calandrino, R ;
Sanguineti, G .
RADIOTHERAPY AND ONCOLOGY, 2005, 74 (02) :187-195