Use of two formulations of Colilert and QuantiTray(TM) for assessment of the bacteriological quality of water

被引:56
作者
Fricker, EJ [1 ]
Illingworth, KS [1 ]
Fricker, CR [1 ]
机构
[1] THAMES WATER UTIL,READING RG2 0JN,BERKS,ENGLAND
关键词
coliforms; E-coli; detection; defined substrate technology; quantitation; Colilert;
D O I
10.1016/S0043-1354(96)00342-9
中图分类号
X [环境科学、安全科学];
学科分类号
08 [工学]; 0830 [环境科学与工程];
摘要
The use of standard Colilert (IDEXX) for the detection of coliforms and E. coli in potable water has been studied. In a large survey, Colilert recovered E. coli from similar numbers of samples to membrane filtration whilst recovery of coliforms was higher with Colilert. Further experiments to study the sensitivity of the two methods using pure cultures, showed that there was no significant difference in their ability to recover E. coli. Studies on a newly developed form of Colilert (Colilert 18) which is said to give results within 18 h showed that there was no significant difference between the two forms of the product. Use of the Colilert Is in a quantitative format using QuantiTray(TM) showed that the product gave similar quantitative results to membrane filtration, but was easier to read and was less time consuming. Subculture of a proportion of positive samples demonstrated that there was no need to confirm results obtained with the Colilert/QuantiTray(TM) system. The results of this study suggest that both formulations of Colilert are suitable alternatives to the United Kingdom membrane filtration method for monitoring the bacteriological quality of drinking water. (C) 1997 Published by Elsevier Science Ltd.
引用
收藏
页码:2495 / 2499
页数:5
相关论文
共 11 条
[1]
ABILITY OF THE COLILERT METHOD TO RECOVER OXIDANT-STRESSED ESCHERICHIA-COLI [J].
BERGER, SA .
LETTERS IN APPLIED MICROBIOLOGY, 1991, 13 (06) :247-250
[2]
NEW MEDIUM FOR THE SIMULTANEOUS DETECTION OF TOTAL COLIFORMS AND ESCHERICHIA-COLI IN WATER [J].
BRENNER, KP ;
RANKIN, CC ;
ROYBAL, YR ;
STELMA, GN ;
SCARPINO, PV ;
DUFOUR, AP .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1993, 59 (11) :3534-3544
[3]
A PRELIMINARY-STUDY OF THE USE OF COLILERT FOR WATER-QUALITY MONITORING [J].
COWBURN, JK ;
GOODALL, T ;
FRICKER, EJ ;
WALTER, KS ;
FRICKER, CR .
LETTERS IN APPLIED MICROBIOLOGY, 1994, 19 (01) :50-52
[4]
EDBERG SC, 1991, J ASSOC OFF ANA CHEM, V74, P526
[5]
FRICKER CR, 1994, P 1993 WAT QUAL TECH, P525
[6]
FRICKER EJ, 1994, LETT APPL MICROBIOL, V19, P53
[7]
EVALUATION OF A RAPID, DEFINED SUBSTRATE TECHNOLOGY METHOD FOR ENUMERATION OF TOTAL COLIFORMS AND ESCHERICHIA-COLI IN CHLORINATED DRINKING-WATER [J].
GALE, P ;
BROBERG, PJ .
LETTERS IN APPLIED MICROBIOLOGY, 1993, 17 (05) :200-203
[8]
A MEDIUM DETECTING BETA-GLUCURONIDASE FOR THE SIMULTANEOUS MEMBRANE FILTRATION ENUMERATION OF ESCHERICHIA-COLI AND COLIFORMS FROM DRINKING-WATER [J].
SARTORY, DP ;
HOWARD, L .
LETTERS IN APPLIED MICROBIOLOGY, 1992, 15 (06) :273-276
[9]
COMPARISON OF COLILERT WITH DUTCH STANDARD ENUMERATION METHODS FOR ESCHERICHIA-COLI AND TOTAL COLIFORMS IN WATER [J].
SCHETS, FM ;
MEDEMA, GJ ;
HAVELAAR, AH .
LETTERS IN APPLIED MICROBIOLOGY, 1993, 17 (01) :17-19
[10]
OBSERVATIONS ON THE USE OF A MEDIUM DETECTING BETA-GLUCURONIDASE ACTIVITY AND LACTOSE FERMENTATION FOR THE SIMULTANEOUS DETECTION OF ESCHERICHIA-COLI AND COLIFORMS [J].
WALTER, KS ;
FRICKER, EJ ;
FRICKER, CR .
LETTERS IN APPLIED MICROBIOLOGY, 1994, 19 (01) :47-49