2-D ultrasound strain images for breast cancer diagnosis using nonrigid subregion registration

被引:12
作者
Chen, Chii-Jen
Chang, Ruey-Feng
Moon, Woo Kyung
Chen, Dar-Ren
Wu, Hwa-Koon
机构
[1] Changhua Christian Hosp, Dept Surg, Changhua, Taiwan
[2] Natl Chung Cheng Univ, Dept Comp Sci & Informat Engn, Chiayi, Taiwan
[3] Seoul Natl Univ Hosp, Dept Radiol, Seoul 110744, South Korea
[4] Seoul Natl Univ Hosp, Clin Res Inst, Seoul 110744, South Korea
[5] Seoul Natl Univ, Med Res Ctr, Inst Radiat Med, Seoul, South Korea
[6] Changhua Christian Hosp, Dept Radiol, Changhua, Taiwan
关键词
strain; ultrasound; level set; image registration; nonrigid registration; subregion registration;
D O I
10.1016/j.ultrasmedbio.2006.02.1406
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Tissue elasticity of a lesion is a useful criterion for the diagnosis of breast ultrasound (US). Elastograms are created by comparing ultrasonic radio-frequency waveforms before and after a light-tissue compression. In this study, we evaluate the accuracy of continuous US strain image in the classification of benign from malignant breast tumors. A series of B-mode US images is applied and each case involves 60 continuous images obtained by using the steady artificial pressure of the US probe. In general, after compression by the US probe, a soft benign tumor will become flatter than a stiffened malignant tumor. We proposed a computer-aided diagnostic (CAD) system by utilizing the nonrigid image registration modality on the analysis of tumor deformation. Furthermore, we used some image preprocessing methods, which included the level set segmentation, to improve the performance. One-hundred pathology-proven cases, including 60 benign breast tumors and 40 malignant tumors, were used in the experiments to test the classification accuracy of the proposed method. Four characteristic values-normalized slope of metric value (NSM), normalized area difference (NAD), normalized standard deviation (NSD) and normalized center translation (NCT)-were computed for all cases. By using the support vector machine, the accuracy, sensitivity, specificity and positive and negative predictive values of the classification of continuous US strain images were satisfactory. The A,, value of the support vector machine based on the four characteristic values used for the classification of solid breast tumors was 0.9358. (c) 2006 World Federation for Ultrasound in Medicine & Biology.
引用
收藏
页码:837 / 846
页数:10
相关论文
共 33 条
[1]  
[Anonymous], 1999, The Nature Statist. Learn. Theory
[2]   ELASTOGRAPHY - ELASTICITY IMAGING USING ULTRASOUND WITH APPLICATION TO MUSCLE AND BREAST IN-VIVO [J].
CESPEDES, I ;
OPHIR, J ;
PONNEKANTI, H ;
MAKLAD, N .
ULTRASONIC IMAGING, 1993, 15 (02) :73-88
[3]  
Chandrashekara R, 2003, LECT NOTES COMPUT SC, V2732, P599
[4]  
Chang JS, 2003, IEEE T DIELECT EL IN, V10, P2
[5]   Improvement in breast tumor discrimination by support vector machines and speckle-emphasis texture analysis [J].
Chang, RF ;
Wu, WJ ;
Moon, WK ;
Chen, DR .
ULTRASOUND IN MEDICINE AND BIOLOGY, 2003, 29 (05) :679-686
[6]   Support vector machines for histogram-based image classification [J].
Chapelle, O ;
Haffner, P ;
Vapnik, VN .
IEEE TRANSACTIONS ON NEURAL NETWORKS, 1999, 10 (05) :1055-1064
[7]   Detection of lines and boundaries in speckle images - Application to medical ultrasound [J].
Czerwinski, RN ;
Jones, DL ;
O'Brien, WD .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1999, 18 (02) :126-136
[8]   Comparison and evaluation of rigid, affine, and nonrigid registration of breast MR images [J].
Denton, ERE ;
Sonoda, LI ;
Rueckert, D ;
Rankin, SC ;
Hayes, C ;
Leach, MO ;
Hill, DLG ;
Hawkes, DJ .
JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1999, 23 (05) :800-805
[9]   Elastography of breast lesions: Initial clinical results [J].
Garra, BS ;
Cespedes, EI ;
Ophir, J ;
Spratt, SR ;
Zuurbier, RA ;
Magnant, CM ;
Pennanen, MF .
RADIOLOGY, 1997, 202 (01) :79-86
[10]   NONLINEAR ANISOTROPIC FILTERING OF MRI DATA [J].
GERIG, G ;
KUBLER, O ;
KIKINIS, R ;
JOLESZ, FA .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1992, 11 (02) :221-232