Influence of PEG architecture on protein adsorption and conformation

被引:283
作者
Michel, R
Pasche, S
Textor, M
Castner, DG
机构
[1] Univ Washington, Natl ESCA, Seattle, WA 98195 USA
[2] Univ Washington, Surface Anal Ctr Biomed Problems, Dept Bioengn, Seattle, WA 98195 USA
[3] Univ Washington, Surface Anal Ctr Biomed Problems, Dept Chem Engn, Seattle, WA 98195 USA
[4] Swiss Fed Inst Technol, Surface Sci & Technol Lab, Zurich, Switzerland
关键词
D O I
10.1021/la051726h
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Poly(L-lysine)-g-poly(ethylene glycol) (PLL-g-PEG) copolymers with various grafting ratios were adsorbed to niobium. pentoxide-coated silicon wafers and characterized before and after protein adsorption using X-ray photoelectron spectroscopy (XPS) and time-of-flight secondary ion mass spectrometry (ToF-SIMS). Three proteins of different sizes, myoglobin (16 kD), albumin (67 kD), and fibrinogen (340 kD), were studied. XPS was used to quantify the amount of protein adsorbed to the bare and PEGylated surfaces. ToF-SIMS and principal component analysis (PCA) were used to study protein conformational changes on these surfaces. The smallest protein, myoglobin, generally adsorbed in higher numbers than the much larger fibrinogen. Protein adsorption was lowest on the surfaces with the highest PEG chain surface density and increased as the PEG layer density decreased. The highest adsorption was found on lysine-coated and bare niobium surfaces. ToF-SIMS and PCA data evaluation provided further information on the degree of protein denaturation, which, for a particular protein, were found to decrease with increasing PEG surface density and increase with decreasing protein size.
引用
收藏
页码:12327 / 12332
页数:6
相关论文
共 46 条
[41]   Characterization of adsorbed protein films using time-of-flight-secondary ion mass spectrometry and multivariate analysis [J].
Wagner, MS ;
Castner, DG .
APPLIED SURFACE SCIENCE, 2003, 203 :698-703
[42]   Characterizing multicomponent adsorbed protein films using electron spectroscopy for chemical analysis, time-of-flight secondary ion mass spectrometry, and radiolabeling: capabilities and limitations [J].
Wagner, MS ;
Horbett, TA ;
Castner, DG .
BIOMATERIALS, 2003, 24 (11) :1897-1908
[43]   Characterization of adsorbed protein films by time-of-flight secondary ion mass spectrometry with principal component analysis [J].
Wagner, MS ;
Castner, DG .
LANGMUIR, 2001, 17 (15) :4649-4660
[44]   Probing the orientation of surface-immobilized immunoglobulin G by time-of-flight secondary ion mass spectrometry [J].
Wang, H ;
Castner, DG ;
Ratner, BD ;
Jiang, SY .
LANGMUIR, 2004, 20 (05) :1877-1887
[45]   Preserving the structure of adsorbed protein films for time-of-flight secondary ion mass spectrometry analysis [J].
Xia, N ;
Castner, DG .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2003, 67A (01) :179-190
[46]   Time-of-flight secondary ion mass spectrometry analysis of conformational changes in adsorbed protein films [J].
Xia, N ;
May, CJ ;
McArthur, SL ;
Castner, DG .
LANGMUIR, 2002, 18 (10) :4090-4097