Tris(2,2′-bipyridyl)ruthenium(II) electrogenerated chemiluminescence sensor based on carbon nantube dispersed in sol-gel-derived titania-Nafion composite films

被引:78
作者
Choi, HN
Lee, JY
Lyu, YK
Lee, WY [1 ]
机构
[1] Yonsei Univ, Dept Chem, Seoul 120749, South Korea
[2] Yonsei Univ, Ctr Bioact Mol Hybrids, Seoul 120749, South Korea
基金
新加坡国家研究基金会;
关键词
electrogenerated chemiluminescence; Ru(bpy)(3) (2+); sol-gel; titania-Nafion composite film; carbon nanotube;
D O I
10.1016/j.aca.2006.01.106
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A highly sensitive and stable tris(2,2'-bipyridyl)ruthenium(II) (Ru(bpy)(3)(2+)) electrogenerated chemiluminescence (ECL) sensor was developed based on carbon nanotube (CNT) dispersed in mesoporous composite films of sol-gel titania and perfluorosulfonated ionomer (Nafion). Single-wall (SWCNT) and multi-wall carbon nanotubes (MWCNT) can be easily dispersed in the titania-Nafion composite solution. The hydrophobic CNT in the titania-Nafion composite films coated on a glassy carbon electrode certainly increased the amount of Ru(bpy)(3)(2+) immobilized in the ECL sensor by adsorption of Ru(bPY)(3)(2+) onto CNT surface, the electrocatalytic activity towards the oxidation of hydrophobic analytes, and the electronic conductivity of the composite films. Therefore, the present ECL sensor based on the CNT-titania-Nafion showed improved ECL sensitivity for tripropylamine (TPA) compared to the ECL sensors based on both titania-Nafion composite films without CNT and pure Nafion films. The present Ru(bPY)(3)(2+) ECL sensor based on the MWCNT-titania-Nafion composite gave a linear response (R-2 = 0.999) for TPA concentration from 50 nM to 1.0 mM with a remarkable detection limit (S/N = 3) of 10 nM while the ECL sensors based on titania-Nafion composite without MWCNT, pure Nafion films, and MWCNT-Nafion composite gave a detection limit of 0.1 mu M, 1 mu M, and 50 nM, respectively. The present ECL sensor showed outstanding long-term stability (no signal loss for 4 months). (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:48 / 55
页数:8
相关论文
共 53 条
[1]   ELECTROGENERATED CHEMI-LUMINESCENCE .40. A CHEMI-LUMINESCENT POLYMER BASED ON THE TRIS(4-VINYL-4'-METHYL-2,2'-BIPYRIDYL)RUTHENIUM(II) SYSTEM [J].
ABRUNA, HD ;
BARD, AJ .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1982, 104 (09) :2641-2642
[2]   Nanotubes from carbon [J].
Ajayan, PM .
CHEMICAL REVIEWS, 1999, 99 (07) :1787-1799
[3]   Carbon nanotube electrode for oxidation of dopamine [J].
Britto, PJ ;
Santhanam, KSV ;
Ajayan, PM .
BIOELECTROCHEMISTRY AND BIOENERGETICS, 1996, 41 (01) :121-125
[4]   ROLE OF ELECTRON-DONATING WITHDRAWING CHARACTER, PH, AND STOICHIOMETRY ON THE CHEMILUMINESCENT REACTION OF TRIS(2,2'-BIPYRIDYL)RUTHENIUM(III) WITH AMINO-ACIDS [J].
BRUNE, SN ;
BOBBITT, DR .
ANALYTICAL CHEMISTRY, 1992, 64 (02) :166-170
[5]   EFFECT OF PH ON THE REACTION OF TRIS(2,2'-BIPYRIDYL)RUTHENIUM(III) WITH AMINO-ACIDS - IMPLICATIONS FOR THEIR DETECTION [J].
BRUNE, SN ;
BOBBITT, DR .
TALANTA, 1991, 38 (04) :419-424
[6]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC DETERMINATION OF ASCORBIC-ACID IN SOFT DRINKS AND APPLE JUICE USING TRIS(2,2'-BIPYRIDINE)RUTHENIUM(II) ELECTROCHEMILUMINESCENCE [J].
CHEN, X ;
SATO, M .
ANALYTICAL SCIENCES, 1995, 11 (05) :749-754
[7]   Sol-gel-immobilized Tris(2,2′-bipyridyl)ruthenium(II) electrogenerated chemiluminescence sensor for high-performance liquid chromatography [J].
Choi, HN ;
Cho, SH ;
Park, YJ ;
Lee, DW ;
Lee, WY .
ANALYTICA CHIMICA ACTA, 2005, 541 (1-2) :49-56
[8]   Electrogenerated chemiluminescence from tris(2,2′-bipyridyl)ruthenium(II) immobilized in titania-perfluorosulfonated lonomer composite films [J].
Choi, HN ;
Cho, SH ;
Lee, WY .
ANALYTICAL CHEMISTRY, 2003, 75 (16) :4250-4256
[9]   Simultaneous direct electrochemiluminescence and catalytic voltammetry detection of DNA in ultrathin films [J].
Dennany, L ;
Forster, RJ ;
Rusling, JF .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2003, 125 (17) :5213-5218
[10]   CHEMILUMINESCENCE DETECTION USING REGENERABLE TRIS(2,2'-BIPYRIDYL)RUTHENIUM(II) IMMOBILIZED IN NAFION [J].
DOWNEY, TM ;
NIEMAN, TA .
ANALYTICAL CHEMISTRY, 1992, 64 (03) :261-268