Tris(2,2′-bipyridyl)ruthenium(II) electrogenerated chemiluminescence sensor based on carbon nantube dispersed in sol-gel-derived titania-Nafion composite films

被引:78
作者
Choi, HN
Lee, JY
Lyu, YK
Lee, WY [1 ]
机构
[1] Yonsei Univ, Dept Chem, Seoul 120749, South Korea
[2] Yonsei Univ, Ctr Bioact Mol Hybrids, Seoul 120749, South Korea
基金
新加坡国家研究基金会;
关键词
electrogenerated chemiluminescence; Ru(bpy)(3) (2+); sol-gel; titania-Nafion composite film; carbon nanotube;
D O I
10.1016/j.aca.2006.01.106
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A highly sensitive and stable tris(2,2'-bipyridyl)ruthenium(II) (Ru(bpy)(3)(2+)) electrogenerated chemiluminescence (ECL) sensor was developed based on carbon nanotube (CNT) dispersed in mesoporous composite films of sol-gel titania and perfluorosulfonated ionomer (Nafion). Single-wall (SWCNT) and multi-wall carbon nanotubes (MWCNT) can be easily dispersed in the titania-Nafion composite solution. The hydrophobic CNT in the titania-Nafion composite films coated on a glassy carbon electrode certainly increased the amount of Ru(bpy)(3)(2+) immobilized in the ECL sensor by adsorption of Ru(bPY)(3)(2+) onto CNT surface, the electrocatalytic activity towards the oxidation of hydrophobic analytes, and the electronic conductivity of the composite films. Therefore, the present ECL sensor based on the CNT-titania-Nafion showed improved ECL sensitivity for tripropylamine (TPA) compared to the ECL sensors based on both titania-Nafion composite films without CNT and pure Nafion films. The present Ru(bPY)(3)(2+) ECL sensor based on the MWCNT-titania-Nafion composite gave a linear response (R-2 = 0.999) for TPA concentration from 50 nM to 1.0 mM with a remarkable detection limit (S/N = 3) of 10 nM while the ECL sensors based on titania-Nafion composite without MWCNT, pure Nafion films, and MWCNT-Nafion composite gave a detection limit of 0.1 mu M, 1 mu M, and 50 nM, respectively. The present ECL sensor showed outstanding long-term stability (no signal loss for 4 months). (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:48 / 55
页数:8
相关论文
共 53 条
[51]   Highly selective and sensitive determination of tricyclic antidepressants in human plasma using high-performance liquid chromatography with post-column tris(2,2′-bipyridyl) ruthenium(III) chemiluminescence detection [J].
Yoshida, H ;
Hidaka, K ;
Ishida, J ;
Yoshikuni, K ;
Nohta, H ;
Yamaguchi, M .
ANALYTICA CHIMICA ACTA, 2000, 413 (1-2) :137-145
[52]   A single calibration graph for the direct determination of ascorbic and dehydroascorbic acids by electrogenerated luminescence based on Ru(bpy)32+ in aqueous solution [J].
Zorzi, M ;
Pastore, P ;
Magno, F .
ANALYTICAL CHEMISTRY, 2000, 72 (20) :4934-4939
[53]   Electrogenerated chemiluminescence.: 66.: The role of direct coreactant oxidation in the ruthenium tris(2,2′)bipyridyl/tripropylamine system and the effect of halide ions on the emission intensity [J].
Zu, YB ;
Bard, AJ .
ANALYTICAL CHEMISTRY, 2000, 72 (14) :3223-3232