Analysis of the Origin of Atypical Scanning Laser Polarimetry Patterns by Polarization-Sensitive Optical Coherence Tomography

被引:23
作者
Goetzinger, Erich [1 ]
Pircher, Michael [1 ]
Baumann, Bernhard [1 ]
Hirn, Cornelia [2 ]
Vass, Clemens [2 ]
Hitzenberger, Christoph K. [1 ]
机构
[1] Gen Hosp, Ctr Biomed Engn & Phys, Vienna, Austria
[2] Gen Hosp, Dept Ophthalmol, Vienna, Austria
基金
奥地利科学基金会;
关键词
D O I
10.1167/iovs.08-2081
中图分类号
R77 [眼科学];
学科分类号
100212 [眼科学];
摘要
PURPOSE. To analyze the physical origin of atypical scanning laser polarimetry (SLP) patterns. To compare polarization-sensitive optical coherence tomography (PS-OCT) scans to SLP images. To present a method to obtain pseudo-SLP images by PS-OCT that are free of atypical artifacts. METHODS. Forty-one eyes of healthy subjects, subjects with suspected glaucoma, and patients with glaucoma were imaged by SLP (GDx VCC) and a prototype spectral domain PS-OCT system. The PS-OCT system acquires three-dimensional (3D) datasets of intensity, retardation, and optic axis orientation simultaneously within 3 seconds. B-scans of intensity and retardation and en face maps of retinal nerve fiber layer (RNFL) retardation were derived from the 3D PS-OCT datasets. Results were compared with those obtained by SLP. RESULTS. Twenty-two eyes showed atypical retardation patterns, and 19 eyes showed normal patterns. From the 22 atypical eyes, 15 showed atypical patterns in both imaging modalities, five were atypical only in SLP images, and two were atypical only in PS-OCT images. In most (15 of 22) atypical cases, an increased penetration of the probing beam into the birefringent sclera was identified as the source of atypical patterns. In such cases, the artifacts could be eliminated in PS-OCT images by depth segmentation and exclusion of scleral signals. CONCLUSIONS. PS-OCT provides deeper insight into the contribution of different fundus layers to SLP images. Increased light penetration into the sclera can distort SLP retardation patterns of the RNFL. (Invest Ophthalmol Vis Sci. 2008;49:5366-5372) DOI: 10.1167/iovs.08-2081
引用
收藏
页码:5366 / 5372
页数:7
相关论文
共 37 条
[1]
[Anonymous], 2014, Z1361 ANSI
[2]
Quantitative assessment of atypical birefringence images using scanning laser polarimetry with variable corneal compensation [J].
Bagga, H ;
Greenfield, DS ;
Feuer, WJ .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2005, 139 (03) :437-446
[3]
Scanning laser polarimetry with variable corneal compensation and optical coherence tomography in normal and glaucomatous eyes [J].
Bagga, H ;
Greenfield, DS ;
Feuer, W ;
Knighton, RW .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2003, 135 (04) :521-529
[4]
Bouma B.E., 2002, Handbook of Optical Coherence Tomography
[5]
The effect of atypical birefringence patterns on glaucoma detection using scanning laser polarimetry with variable corneal compensation [J].
Bowd, Christopher ;
Medeiros, Felipe A. ;
Weinreb, Robert N. ;
Zangwill, Linda M. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2007, 48 (01) :223-227
[6]
Thickness and birefringence of healthy retinal nerve fiber layer tissue measured with polarization-sensitive optical coherence tomography [J].
Cense, B ;
Chen, TC ;
Park, BH ;
Pierce, MC ;
de Boer, JF .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 (08) :2606-2612
[7]
In vivo depth-resolved birefringence measurements of the human retinal nerve fiber layer by polarization-sensitive optical coherence tomography [J].
Cense, B ;
Chen, TC ;
Park, BH ;
Pierce, MC ;
de Boer, JF .
OPTICS LETTERS, 2002, 27 (18) :1610-1612
[8]
Atypical pattern of retardation on GDx-VCC and its effect on retinal nerve fibre layer evaluation in glaucomatous eyes [J].
Da Pozzo, S. ;
Marchesan, R. ;
Canziani, T. ;
Vattovani, O. ;
Ravalico, G. .
EYE, 2006, 20 (07) :769-775
[9]
Two-dimensional birefringence imaging in biological tissue by polarization-sensitive optical coherence tomography [J].
deBoer, JF ;
Milner, TE ;
vanGemert, MJC ;
Nelson, JS .
OPTICS LETTERS, 1997, 22 (12) :934-936
[10]
SPATIALLY RESOLVED BIREFRINGENCE OF THE RETINAL NERVE-FIBER LAYER ASSESSED WITH A RETINAL LASER ELLIPSOMETER [J].
DREHER, AW ;
REITER, K ;
WEINREB, RN .
APPLIED OPTICS, 1992, 31 (19) :3730-3735