The effect of atypical birefringence patterns on glaucoma detection using scanning laser polarimetry with variable corneal compensation

被引:32
作者
Bowd, Christopher [1 ]
Medeiros, Felipe A. [1 ]
Weinreb, Robert N. [1 ]
Zangwill, Linda M. [1 ]
机构
[1] Univ Calif San Diego, Hamilton Glaucoma Ctr, Dept Ophthalmol, La Jolla, CA 92093 USA
关键词
D O I
10.1167/iovs.06-0787
中图分类号
R77 [眼科学];
学科分类号
100212 [眼科学];
摘要
PURPOSE. The purpose of this study was to investigate the effect of the presence of atypical birefringence patterns, as measured by the typical scan score (TSS), on the diagnostic accuracy of a scanning laser polarimeter (the GDx VCC; Carl Zeiss Meditec, Inc., Dublin, CA) assessed by receiver operating characteristic (ROC) curves for discriminating between glaucoma and healthy eyes. METHODS. Two hundred thirty-three glaucomatous eyes (repeatable abnormal visual fields by pattern standard deviation [PSD] and/or glaucoma hemifield test [GHT]) from 153 patients with glaucoma and 104 eyes from 71 healthy participants enrolled in the UCSD Diagnostic Innovations in Glaucoma Study (DIGS) were imaged using the GDx VCC. An ROC regression model was used to evaluate the influence of the covariates TSS; disease severity, defined as standard automated perimetry (SAP) mean deviation [MD]; and age in years on the diagnostic accuracy of the GDx parameters nerve fiber indicator [NFI], TSNIT (temporal, superior, nasal, inferior, temporal) average thickness, superior average thickness, inferior average thickness, and TSNIT standard deviation. Areas under the ROC curve were calculated for specific levels of the covariates according to the results provided by the model. RESULTS. TSS and SAP MD significantly affected the diagnostic accuracy of each investigated GDx VCC parameter. Low TSSs, indicating the presence of atypical scans, were associated with decreased accuracy. For NFI, ROC curve areas ranged from 0.749 (when TSS = 20) to 0.904 (when TSS = 100). A similar influence of TSS was found for other parameters. In addition, diagnostic accuracy increased with increasing disease severity. For instance, for NFI, ROC curve areas ranged from 0.853 (when SAP MD = -3) to 0.954 (when SAP MD = -15). CONCLUSIONS. The diagnostic accuracy of GDx VCC parameters is affected by disease severity and is adversely affected by the presence of atypical retardation patterns (i.e., decreasing TSS). GDx VCC scans with atypical scan patterns should be interpreted with caution when used in clinical practice.
引用
收藏
页码:223 / 227
页数:5
相关论文
共 18 条
[1]
Quantitative assessment of atypical birefringence images using scanning laser polarimetry with variable corneal compensation [J].
Bagga, H ;
Greenfield, DS ;
Feuer, WJ .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2005, 139 (03) :437-446
[2]
Scanning laser polarimetry with variable corneal compensation and optical coherence tomography in normal and glaucomatous eyes [J].
Bagga, H ;
Greenfield, DS ;
Feuer, W ;
Knighton, RW .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2003, 135 (04) :521-529
[3]
Association between scanning laser polarimetry measurements using variable corneal polarization compensation and visual in field sensitivity glaucomatous eyes [J].
Bowd, C ;
Zangwill, LM ;
Weinreb, RN .
ARCHIVES OF OPHTHALMOLOGY, 2003, 121 (07) :961-966
[4]
Discrimination between normal and early glaucomatous eyes with scanning laser polarimeter with fixed and variable corneal compensator settings [J].
Brusini, P ;
Salvetat, ML ;
Parisi, L ;
Zeppieri, M ;
Tosoni, C .
EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2005, 15 (04) :468-476
[5]
Atypical pattern of retardation on GDx-VCC and its effect on retinal nerve fibre layer evaluation in glaucomatous eyes [J].
Da Pozzo, S. ;
Marchesan, R. ;
Canziani, T. ;
Vattovani, O. ;
Ravalico, G. .
EYE, 2006, 20 (07) :769-775
[6]
Effect of cataract extraction and intraocular lens implantation on nerve fibre layer thickness measurements by scanning laser polarimeter (GDx) in glaucoma patients [J].
Gazzard, G ;
Foster, PJ ;
Devereux, JG ;
Oen, F ;
Chew, PTK ;
Khaw, PT ;
Seah, SKL .
EYE, 2004, 18 (02) :163-168
[7]
Correction for corneal polarization axis improves the discriminating power of scanning laser polarimetry [J].
Greenfield, DS ;
Knighton, RW ;
Feuer, WJ ;
Schiffman, JC ;
Zangwill, L ;
Weinreb, RN .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2002, 134 (01) :27-33
[8]
Influence of cataract surgery with implantation of different intraocular lenses on scanning laser tomography and polarimetry [J].
Kremmer, S ;
Garway-Heath, DF ;
De Cilla, S ;
Steuhl, KP ;
Selbach, JM .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2003, 136 (06) :1016-1021
[9]
Influence of disease severity and optic disc size on the diagnostic performance of imaging instruments in glaucoma [J].
Medeiros, FA ;
Zangwill, LM ;
Bowd, C ;
Sample, PA ;
Weinreb, RN .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2006, 47 (03) :1008-1015
[10]
A statistical approach to the evaluation of covariate effects on the receiver operating characteristic curves of diagnostic tests in glaucoma [J].
Medeiros, Felipe A. ;
Sample, Pamela A. ;
Zangwill, Linda M. ;
Liebmann, Jeffrey M. ;
Girkin, Christopher A. ;
Weinreb, Robert N. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2006, 47 (06) :2520-2527