High-performance liquid chromatography coupled with electrospray tandem mass spectrometry (LC/MS/MS) method for the simultaneous determination of diazepam, atropine and pralidoxime in human plasma

被引:48
作者
Abbara, Chadi [1 ,2 ]
Bardot, Isabelle [3 ]
Cailleux, Annie [1 ,2 ]
Lallement, Guy [4 ]
Le Bouil, Anne [1 ,2 ]
Turcant, Alain [1 ,2 ]
Clair, Pascal [3 ]
Diquet, Bertrand [1 ,2 ]
机构
[1] CHU Angers, Serv Pharmacol Toxicol, F-49933 Angers 09, France
[2] Univ Angers, UFR Med, F-49045 Angers, France
[3] Pharm Cent Armees, F-45998 Orleans, France
[4] Ctr Rech Serv Sante Armes, Unite Neuropharmacol, F-38702 La Tronche, France
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2008年 / 874卷 / 1-2期
关键词
Avizafone; Diazepam; Atropine; Pralidoxime; Liquid chromatography/tandem mass spectrometry; Pharmacokinetics; Organophosphate agents;
D O I
10.1016/j.jchromb.2008.08.027
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A high-performance liquid chromatography coupled with electrospray tandem mass spectrometry (LC/MS/MS) procedure for the simultaneous determination of diazepam from avizafone, atropine and pralidoxime in human plasma is described. Sample pretreatment consisted of protein precipitation from 100 mu l of plasma using acetonitrile containing the internal standard (diazepam D5). Chromatographic separation was performed on a X-Terra (R) MS C-8 column (100 mm x 2.1 mm, i.d. 3.5 mu m), with a quick step-wise gradient using a formate buffer (pH 3. 2 mM) and acetonitrile at a flow rate of 0.2 ml/min. The triple quadrupole mass spectrometer was operated in positive ion mode and multiple reaction monitoring was used for drug quantification. The method was validated over the concentration ranges of 1-500 ng/ml for diazepam, 0.25-50 ng/ml for atropine and 5-1000 ng/ml for pralidoxime. The coefficients of variation were always <15% for both intra-day and inter-day precision for each analyte. Mean accuracies were also within +/- 15%. This method has been successfully applied to a pharmacokinetic study of the three compounds after intramuscular injection of an avizafone-atropine-pralidoxime combination. in healthy subjects. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:42 / 50
页数:9
相关论文
共 29 条
[1]  
[Anonymous], 2001, Guidance for Industry-bioanalytical method validation
[2]   Organophosphates/nerve agent poisoning: Mechanism of action, diagnosis, prophylaxis, and treatment [J].
Bajgar, J .
ADVANCES IN CLINICAL CHEMISTRY, VOL. 38, 2004, 38 :151-216
[3]   Detection and validated quantification of toxic alkaloids in human blood plasma - comparison of LC-APCI-MS with LC-ESI-MS/MS [J].
Beyer, Jochen ;
Peters, Frank T. ;
Kraemer, Thomas ;
Maurer, Hans H. .
JOURNAL OF MASS SPECTROMETRY, 2007, 42 (05) :621-633
[4]   Quantification by HPLC-MS/MS of atropine in human serum and clinical presentation of six mild-to-moderate intoxicated atropine-adulterated-cocaine users [J].
Boermans, PAMM ;
Go, HS ;
Wessels, AMA ;
Uges, DRA .
THERAPEUTIC DRUG MONITORING, 2006, 28 (03) :295-298
[5]  
Bonfiglio R, 1999, RAPID COMMUN MASS SP, V13, P1175, DOI 10.1002/(SICI)1097-0231(19990630)13:12<1175::AID-RCM639>3.0.CO
[6]  
2-0
[7]   ANTICONVULSANT ACTIONS OF ANTICHOLINERGIC DRUGS IN SOMAN POISONING [J].
CAPACIO, BR ;
SHIH, TM .
EPILEPSIA, 1991, 32 (05) :604-615
[8]   ATROPINE - A SENSITIVE GAS CHROMATOGRAPHY-MASS SPECTROMETRY ASSAY AND PRE-PHARMACOKINETIC STUDIES [J].
ECKERT, M ;
HINDERLING, PH .
AGENTS AND ACTIONS, 1981, 11 (05) :520-531
[9]   High-performance liquid chromatographic method for the determination of benzodiazepines in plasma or serum using the column-switching technique [J].
El Mahjoub, A ;
Staub, C .
JOURNAL OF CHROMATOGRAPHY B, 2000, 742 (02) :381-390
[10]   Measurement of serum pralidoxime methylsulfate (Contrathion®) by high-performance liquid chromatography with electrochemical detection [J].
Houzé, P ;
Borron, SW ;
Scherninski, F ;
Bousquet, B ;
Gourmel, B ;
Baud, F .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2005, 814 (01) :149-154