Simultaneous B-M-mode scanning method for real-time full-range Fourier domain optical coherence tomography

被引:122
作者
Yasuno, Y [1 ]
Makita, S [1 ]
Endo, T [1 ]
Aoki, G [1 ]
Itoh, M [1 ]
Yatagai, T [1 ]
机构
[1] Univ Tsukuba, Inst Appl Phys, Tsukuba, Ibaraki 3058573, Japan
关键词
D O I
10.1364/AO.45.001861
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
High-speed complex full-range Fourier domain optical coherence tomography (FD-OCT) is demonstrated. In this FD-OCT, the phase modulation of a reference beam (M scan) and transversal scanning (B scan) are simultaneously performed. The Fourier transform method is applied along the direction of the B scan to reconstruct complex spectra, and the complex spectra comprise a full-range OCT image. Because of this simultaneous B-M-mode scan, the FD-OCT requires only a single A scan for each single transversal position to obtain a full-range FD-OCT image. A simple but slow version of the FD-OCT visualizes the cross section of a plastic plate. A modified fast version of this FD-OCT investigates a sweat duct in a finger pad in vivo and visualizes it with an acquisition time of 27 ms. (c) 2006 Optical Society of America.
引用
收藏
页码:1861 / 1865
页数:5
相关论文
共 22 条
[1]   Optical coherence tomography by "Spectral Radar":: Dynamic range estimation and in vivo measurements of skin [J].
Andretzky, P ;
Lindner, MW ;
Herrmann, JM ;
Schultz, A ;
Konzog, M ;
Kiesewetter, F ;
Häusler, G .
OPTICAL AND IMAGING TECHNIQUES FOR BIOMONITORING IV, PROCEEDINGS OF, 1999, 3567 :78-87
[2]  
Goodman J.W., 1996, Opt. Eng, V35, P1513, DOI DOI 10.1016/J.APSUSC.2017.08.033
[3]   High speed full range complex spectral domain optical coherence tomography [J].
Götzinger, E ;
Pircher, M ;
Leitgeb, RA ;
Hitzenberger, CK .
OPTICS EXPRESS, 2005, 13 (02) :583-594
[4]  
GREIVENKAMP JE, 1992, OPTICAL SHOP TESTING, P501
[5]  
Häusler G, 1998, J BIOMED OPT, V3, P21, DOI 10.1117/1.429899
[6]   OPTICAL COHERENCE TOMOGRAPHY [J].
HUANG, D ;
SWANSON, EA ;
LIN, CP ;
SCHUMAN, JS ;
STINSON, WG ;
CHANG, W ;
HEE, MR ;
FLOTTE, T ;
GREGORY, K ;
PULIAFITO, CA ;
FUJIMOTO, JG .
SCIENCE, 1991, 254 (5035) :1178-1181
[7]   Spectral measurement of absorption by spectroscopic frequency-domain optical coherence tomography [J].
Leitgeb, R ;
Wojtkowski, M ;
Kowalczyk, A ;
Hitzenberger, CK ;
Sticker, M ;
Fercher, AF .
OPTICS LETTERS, 2000, 25 (11) :820-822
[8]   Performance of fourier domain vs. time domain optical coherence tomography [J].
Leitgeb, R ;
Hitzenberger, CK ;
Fercher, AF .
OPTICS EXPRESS, 2003, 11 (08) :889-894
[9]   Real-time assessment of retinal blood flow with ultrafast acquisition by color Doppler Fourier domain optical coherence tomography [J].
Leitgeb, RA ;
Schmetterer, L ;
Drexler, W ;
Fercher, AF ;
Zawadzki, RJ ;
Bajraszewski, T .
OPTICS EXPRESS, 2003, 11 (23) :3116-3121
[10]   Phase-shifting algorithm to achieve high-speed long-depth-range probing by frequency-domain optical coherence tomography [J].
Leitgeb, RA ;
Hitzenberger, CK ;
Fercher, AF ;
Bajraszewski, T .
OPTICS LETTERS, 2003, 28 (22) :2201-2203