High accuracy mass measurement of peptides with internal calibration using a dual electrospray ionization sprayer system for protein identification

被引:24
作者
Zhou, F
Shui, WQ
Lu, Y
Yang, PY [1 ]
Gu, YL
机构
[1] Fudan Univ, Dept Chem, Shanghai 200433, Peoples R China
[2] Chinese Acad Sci, Shanghai Inst Organ Chem, Shanghai 200032, Peoples R China
关键词
D O I
10.1002/rcm.603
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A dual-ESI-sprayer system was constructed and applied to achieve high accuracy of peptide mass measurement for protein identification by means of peptide mapping. Sample was introduced in one sprayer, and reference in the other, thus making internal calibration possible greatly enhancing the mass accuracy. Several samples were utilized to evaluate the reliability of this dual-ESI-sprayer system. The range of mass errors was 0.16-5.37ppm. The peptide masses of tryptic digests of myoglobin (horse) were measured by the HPLC/dual-ESI-MS system, with mass deviations ranging from 0.01-7.67 ppm, and about 75% mass deviations below 5 ppm with 40% below 1 ppm. These peptide masses were utilized to perform database searching for protein identification, and compared to results obtained by external calibration. This comparison showed that the internal calibration provides a more reliable method of protein identification, with a much smaller number of required peptides for matching, and with less CPU time consumed for database searching. Copyright (C) 2002 John Wiley Sons, Ltd.
引用
收藏
页码:505 / 511
页数:7
相关论文
共 19 条
[1]   Mass spectrometry in proteomics [J].
Aebersold, R ;
Goodlett, DR .
CHEMICAL REVIEWS, 2001, 101 (02) :269-295
[2]   Principal component analysis of mass spectra of peptides generated from the tryptic digestion of protein mixtures [J].
Bryant, DK ;
Monté, S ;
Man, WJ ;
Kramer, K ;
Bugelski, P ;
Neville, W ;
White, IR ;
Camilleri, P .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2001, 15 (06) :418-427
[3]   Role of accurate mass measurement (±10 ppm) in protein identification strategies employing MS or MS MS and database searching [J].
Clauser, KR ;
Baker, P ;
Burlingame, AL .
ANALYTICAL CHEMISTRY, 1999, 71 (14) :2871-2882
[4]   Utility of accurate mass tags for proteome-wide protein identification [J].
Conrads, TP ;
Anderson, GA ;
Veenstra, TD ;
Pasa-Tolic, L ;
Smith, RD .
ANALYTICAL CHEMISTRY, 2000, 72 (14) :3349-3354
[5]   Accurate mass liquid chromatography/mass spectrometry on orthogonal acceleration time-of-flight mass analyzers using switching between separate sample and reference sprays. 1. Proof of concept [J].
Eckers, C ;
Wolff, JC ;
Haskins, NJ ;
Sage, AB ;
Giles, K ;
Bateman, R .
ANALYTICAL CHEMISTRY, 2000, 72 (16) :3683-3688
[6]   High-mass accuracy of product ions produced by SORI-CID using a dual electrospray ionization source coupled with FTICR mass spectrometry [J].
Flora, JW ;
Hannis, JC ;
Muddiman, DC .
ANALYTICAL CHEMISTRY, 2001, 73 (06) :1247-1251
[7]  
Hakansson K, 1998, RAPID COMMUN MASS SP, V12, P705, DOI 10.1002/(SICI)1097-0231(19980615)12:11<705::AID-RCM212>3.0.CO
[8]  
2-3
[9]   Design and performance of an electrospray ionization time-of-flight mass spectrometer [J].
Håkansson, K ;
Zubarev, RA ;
Håkansson, P ;
Laiko, V ;
Dodonov, AF .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2000, 71 (01) :36-41
[10]   IDENTIFYING PROTEINS FROM 2-DIMENSIONAL GELS BY MOLECULAR MASS SEARCHING OF PEPTIDE-FRAGMENTS IN PROTEIN-SEQUENCE DATABASES [J].
HENZEL, WJ ;
BILLECI, TM ;
STULTS, JT ;
WONG, SC ;
GRIMLEY, C ;
WATANABE, C .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1993, 90 (11) :5011-5015