Flat panel detector-based cone beam volume CT imaging: detector evaluation

被引:34
作者
Ning, R [1 ]
Tang, XY [1 ]
Yu, RF [1 ]
Conover, D [1 ]
Zhang, DH [1 ]
机构
[1] Univ Rochester, Dept Radiol, Rochester, NY 14642 USA
来源
MEDICAL IMAGING 1999: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2 | 1999年 / 3659卷
关键词
flat panel dector; cone beam reconstruction; volume CT; spiral CT;
D O I
10.1117/12.349492
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Recent development of large area flat panel solid state detector arrays indicates that flat panel image sensors have some common potential advantages: compactness, absence of geometric distortion and veiling glare with the benefits of high resolution, high DQE, high frame rate:and high dynamic range, small image lag (<1%) and excellent linearity (similar to 1%). The advantages of the new flat-panel detector make it a promising candidate for cone beam volume CT imaging. The purpose of this study is to characterize an amorphous silicon thin film transistor (STFT) flat panel detector-based imaging system for cone beam volume CT applications. A prototype STFT detector-based-cone beam volume CT imaging system has been designed and constructed based on the modification of-a GE 8800 CT scanner. This system is evaluated using two phantoms: a low contrast phantom, and a GE-CT quality assurance phantom. The results indicate that the flat panel,detector-based volume cone beam can achieve a better spatial resolution than that of a standard fan beam CT and a low contrast resolution approaching that of a standard fan beam CT. The results also suggest that to use a flat panel detector for cone beam Volume CT, the design and construction of the detector should be optimized for tomographic acquisition and reconstruction.
引用
收藏
页码:192 / 203
页数:12
相关论文
共 9 条
  • [1] ANTONUK LE, 1993, MATER RES SOC SYMP P, V297, P945, DOI 10.1557/PROC-297-945
  • [2] DEMONSTRATION OF MEGAVOLTAGE AND DIAGNOSTIC-X-RAY IMAGING WITH HYDROGENATED AMORPHOUS-SILICON ARRAYS
    ANTONUK, LE
    BOUDRY, J
    HUANG, WD
    MCSHAN, DL
    MORTON, EJ
    YORKSTON, J
    LONGO, MJ
    STREET, RA
    [J]. MEDICAL PHYSICS, 1992, 19 (06) : 1455 - 1466
  • [3] Characterization of an amorphous silicon fluoroscopic imager
    Colbeth, RE
    Allen, MJ
    Day, DJ
    Gilblom, DL
    KlausmeierBrown, ME
    Pavkovich, J
    Seppi, EJ
    Shapiro, EG
    [J]. PHYSICS OF MEDICAL IMAGING - MEDICAL IMAGING 1997, 1997, 3032 : 42 - 51
  • [4] PRACTICAL CONE-BEAM ALGORITHM
    FELDKAMP, LA
    DAVIS, LC
    KRESS, JW
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1984, 1 (06): : 612 - 619
  • [5] LEE DL, 1995, P SOC PHOTO-OPT INS, V2432, P237, DOI 10.1117/12.208342
  • [6] Selenium flat panel detector-based volume tomographic angiography imaging: Phantom studies
    Ning, RL
    Lee, D
    Wang, XH
    Zhang, Y
    Conover, D
    Zhang, DH
    Williams, C
    [J]. PHYSICS OF MEDICAL IMAGING, 1998, 3336 : 316 - 324
  • [7] TANG X, 1999, SPIE MI 99
  • [8] ZHAO W, 1992, P SOC PHOTO-OPT INS, V1651, P134, DOI 10.1117/12.59391
  • [9] X-RAY-IMAGING USING AMORPHOUS SELENIUM - FEASIBILITY OF A FLAT-PANEL SELF-SCANNED DETECTOR FOR DIGITAL RADIOLOGY
    ZHAO, W
    ROWLANDS, JA
    [J]. MEDICAL PHYSICS, 1995, 22 (10) : 1595 - 1604