Implantable cardioverter defibrillators and cellular telephones: Is there any interference?

被引:40
作者
Occhetta, E
Plebani, L
Bortnik, M
Sacchetti, G
Trevi, G
机构
[1] Univ Studi Torino, Div Clin Cardiol, Fac Med & Chirurg 2, Sede Novara, Novara, Italy
[2] Azienda Osped Maggiore Carita, Uff Tecn, Novara, Italy
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 1999年 / 22卷 / 07期
关键词
cellular telephones; implantable cardioverter defibrillator; electromagnetic interference;
D O I
10.1111/j.1540-8159.1999.tb00561.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The aim of our study was to consider cellular telephone interference using different cellular telephones and implantable cardioverter defibrillator (ICD) models. Thirty (26 men, 4 women) patients with ICDs were considered during follow-up. The ICD models were: Telectronics (7), CPI (7), Medtronic (7), Ventritex (5), and Ela Medical (4). All patients were monitored with surface EGG; permanent telemetric endo-ECG monitoring was activated. Then, the effect of two different European telephone systems were tested: TACS system (Sony CM-R111, 2 W power) and GSM system (Motorola MG1-4A11, 2 W power). For both systems, the effect during call, reception, active conversation (dialogue), and passive conversation (listening) were observed. Cellular telephones were located first in contact with the programming head, then near the leads system, and lastly, in the hands of the patient. At the end of the evaluations, memories were interrogated again to check for false arrhythmia detections. In five of these patients during arrhythmia induction at device implant (first implant or ICD replacement), we also evaluated possible interference between cellular telephones in the reception phase and the ventricular fibrillation detection phase of the ICD. All evaluated models showed significant noise in the telemetric transmission when the cellular telephone (both TAGS and GSM) was located near the ICD and the programming head; noise was particularly significant during call and reception, in most cases leading to loss of telemetry. No false arrhythmia detections have been observed during tests with cellular telephones located on the ICDs. During tests performed with cellular telephones located near the leads or in the hands of patients, no telemetric noises or false arrhythmia detections were observed. During induced ventricular fibrillation and cellular telephones in reception mode near the device, the arrhythmia recognition was always correct and not delayed. In conclusion, present ICD models seem to be well protected from electromagnetic interference caused by European cellular telephones (TACS and GSM), without under-/oversensing of ventricular arrhythmias. However, cellular telephones disturb telemetry when located near the programming head. ICD patients should not be advised against the use of cellular telephones, but it hers to be avoided during ICD interrogation and programming.
引用
收藏
页码:983 / 989
页数:7
相关论文
共 30 条
[1]  
ALTAMURA G, 1996, G ITAL CARDIOL S1, V26, P134
[2]  
ALTAMURA G, 1996, G ITAL CARDIOL S1, V26, P129
[3]   DO EUROPEAN GSM MOBILE CELLULAR PHONES POSE A POTENTIAL RISK TO PACEMAKER PATIENTS [J].
BARBARO, V ;
BARTOLINI, P ;
DONATO, A ;
MILITELLO, C ;
ALTAMURA, G ;
AMMIRATI, F ;
SANTINI, M .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1995, 18 (06) :1218-1224
[4]   Electromagnetic interference of analog cellular telephones with pacemakers [J].
Barbaro, V ;
Bartolini, P ;
Donato, A ;
Militello, C .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1996, 19 (10) :1410-1418
[5]  
BARBARO V, 1997, P 1 INT C CARD TRANS
[6]  
Bassen H, 1995, CIRCULATION, V92, pI
[7]  
Beaugeard D, 1992, Arch Mal Coeur Vaiss, V85, P1457
[8]   THE EFFECT OF METAL DETECTOR GATES ON IMPLANTED PERMANENT PACEMAKERS [J].
COPPERMAN, Y ;
ZARFATI, D ;
LANIADO, S .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1988, 11 (10) :1386-1387
[9]   ELECTRONIC ARTICLE SURVEILLANCE - A POSSIBLE DANGER FOR PACEMAKER PATIENTS [J].
DODINOT, B ;
GODENIR, JP ;
COSTA, AB ;
ZELLER, C ;
BROSCHART, M .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1993, 16 (01) :46-53
[10]  
*EUR COMM EL STAND, 500611988A11995 CENE