Rapid measurement of deuterium content of breath following oral ingestion to determine body water

被引:36
作者
Davies, S
Spanel, P
Smith, D
机构
[1] Keele Univ, Postgrad Med Sch, Ctr Sci & Technol Med, Keele, Staffs, England
[2] Acad Sci Czech Republ, J Heyrovsky Inst Phys Chem, Prague, Czech Republic
关键词
body composition; total body water; breath analysis; flow-afterglow mass spectrometry; non-invasive; deuterium dilution;
D O I
10.1088/0967-3334/22/4/301
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The ability to measure total body water accurately, non-invasively and rapidly with results that are immediately available would represent an important advance in body composition research. Flowing afterglow mass spectrometry (FA-MS) has been developed to enable immediate measurement of deuterium content in breath water from single exhalations. which when combined with oral D2O loading enables measurement of total body water. We report here its first use in normal subjects, demonstrating the dispersal kinetics of deuterium in the body by monitoring deuterium in breath water following ingestion. Ten studies were performed in six normal subjects. After obtaining baseline samples, each subject ingested 0.3 g kg(-1) of 99.9% pure D2O. Subsequently, breath samples were obtained every 3-5 minutes until equilibration had occurred. Three distinct phases in breath deuterium content were observed: an initial immediate peak due to HDO remaining in the oral cavity, a secondary peak reflecting gastrointestinal absorption and finally equilibration with the body water. The incremental increase in breath deuterium abundance between baseline and equilibration was used to calculate the total body water. Mathematical fitting of this final equilibration phase demonstrated that the measured deuterium abundance was within 0.2% of the ideal (asymptotic) value within 2 hours in all cases. We conclude that FA-MS is a powerful new method that, when combined with oral D2O loading, enables measurement of the dispersal kinetics of HDO and the calculation of total body water within 2 hours.
引用
收藏
页码:651 / 659
页数:9
相关论文
共 15 条
[1]  
Abraham W T, 1993, Curr Opin Nephrol Hypertens, V2, P798
[2]   Comparing different methods of assessing body composition in end-stage renal failure [J].
Cooper, BA ;
Aslani, A ;
Ryan, M ;
Zhu, FYP ;
Ibels, LS ;
Allen, BJ ;
Pollock, CA .
KIDNEY INTERNATIONAL, 2000, 58 (01) :408-416
[3]   BODY-COMPOSITION IN NONALCOHOLIC CIRRHOSIS - THE EFFECT OF DISEASE ETIOLOGY AND SEVERITY ON NUTRITIONAL COMPARTMENTS [J].
CRAWFORD, DHG ;
SHEPHERD, RW ;
HALLIDAY, JW ;
COOKSLEY, GWGE ;
GOLDING, SD ;
CHENG, WSC ;
POWELL, LW .
GASTROENTEROLOGY, 1994, 106 (06) :1611-1617
[4]   STABLE ISOTOPES IN CLINICAL RESEARCH - SAFETY REAFFIRMED [J].
JONES, PJH ;
LEATHERDALE, ST .
CLINICAL SCIENCE, 1991, 80 (04) :277-280
[5]   DEUTERIUM DILUTION AS A METHOD FOR DETERMINING TOTAL-BODY WATER - EFFECT OF TEST PROTOCOL AND SAMPLING TIME [J].
LICHTENBELT, WDV ;
WESTERTERP, KR ;
WOUTERS, L .
BRITISH JOURNAL OF NUTRITION, 1994, 72 (04) :491-497
[6]   Asymmetry of the total body water prediction bias using the impedance index [J].
Piccoli, A ;
Pillon, L ;
Favaro, E .
NUTRITION, 1997, 13 (05) :438-441
[7]   TOTAL-BODY WATER MEASUREMENT IN HUMANS WITH O-18 AND H-2 LABELED WATER [J].
SCHOELLER, DA ;
VANSANTEN, E ;
PETERSON, DW ;
DIETZ, W ;
JASPAN, J ;
KLEIN, PD .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 1980, 33 (12) :2686-2693
[8]  
Smith D, 2001, RAPID COMMUN MASS SP, V15, P25, DOI 10.1002/1097-0231(20010115)15:1<25::AID-RCM187>3.0.CO
[9]  
2-2
[10]   Accuracy and precision of flowing afterglow mass spectrometry for the determination of the deuterium abundance in the headspace of aqueous liquids and exhaled breath water [J].
Spanel, P ;
Smith, D .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2001, 15 (11) :867-872