Abutment region dosimetry for serial tomotherapy

被引:27
作者
Low, DA [1 ]
Mutic, S [1 ]
Dempsey, JF [1 ]
Markman, J [1 ]
Goddu, SM [1 ]
Purdy, JA [1 ]
机构
[1] Washington Univ, Div Radiat Oncol, Mallinckrodt Inst Radiol, Med Ctr, St Louis, MO 63110 USA
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 1999年 / 45卷 / 01期
关键词
intensity modulated radiation therapy; radiation therapy quality assurance; serial tomotherapy;
D O I
10.1016/S0360-3016(99)00125-X
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: A commercial intensity modulated radiation therapy system (Corvus, NOMOS Corp.) is presently used in our clinic to generate optimized dose distributions delivered using a proprietary dynamic multileaf collimator (DMLC) (MIMiC) composed of 20 opposed leaf pairs. On our accelerator (Clinac 600C/D, Varian Associates, Inc.) each MIMiC leaf projects to either 1.00 x 0.84 or 1.00 x 1.70 cm(2) (depending on the treatment plan and termed 1 cm or 7 cm mode, respectively). The MIMiC is used to deliver serial (axial) tomotherapy treatment plans, in which the beam is delivered to a nearly cylindrical volume as the DMLC is rotated about the patient. For longer targets, the patient is moved (indexed) between treatments a distance corresponding to the projected leaf width, The treatment relies on precise indexing and a method was developed to measure the precision of indexing devices. A treatment planning study of the dosimetric effects of incorrect patient indexing and concluded that a dose heterogeneity of 10% mm(-1) resulted, Because the results may be sensitive to the dose model accuracy, we conducted a measurement-based investigation of the consequences of incorrect indexing using our accelerator, Although the indexing pro provides an accurate field abutment along the isocenter, due to beam divergence, hot and cold spots,,ill be produced below and above isocenter, respectively, when less than 300 degrees arcs a ere used, A preliminary study recently determined that for a 290 degrees rotation in 1 cm mode, 15% cold and 7% hot spots were delivered to 7 cm above and below isocenter, respectively. This study completes the earlier work by investigating the dose heterogeneity as a function of position relative to the axis of rotation, are length, and leaf width, The influence of random daily patient positioning errors is also investigated, Methods and Materials: Treatment plans were generated using 8.0 cm diameter cylindrical target volumes within a homogeneous rectilinear film phantom, The plans included both 1 and 2 cm mode, optimized for 300 degrees, 240 degrees, and 180 degrees gantry rotations. Coronal-oriented films were irradiated throughout the target volumes and scanned using a laser film digitizer, The central target irradiated in 1 cm mode was also used to investigate the effects of incorrect couch indexing, Results: The dose error as a function of couch index error was 25% mm(-1), significantly greater than previously reported, The clinically provided indexing system yielded 0.10 mm indexing precision. The intrinsic dose distributions indicated that more heterogeneous dose distributions resulted from the use of smaller gantry angle ranges and larger leaf projections, Using 300 degrees gantry angle and 1 cm mode yielded 7% hot and 15% cold spots 7 cm below and above isocenter, respectively. When a 180 degrees gantry angle was used, the values changed to 22% hot and 27% fold spots for the same locations. The heterogeneities for the 2 cm mode were 70% greater than the corresponding 1 cm values. Conclusions: While serial tomotherapy is used to deliver highly conformal dose distributions, significant dosimetric factors must be considered before treatment. The patient must be immobilized during treatment to avoid dose heterogeneities caused by incorrect indexing due to patient movement. Even under ideal conditions, beam divergence can cause significant abutment-region dose heterogeneities. The use of larger gantry angle ranges, smaller leaf widths, and appropriate locations of the gantry rotation axis can minimize these effects. (C) 1999 Elsevier Science Inc.
引用
收藏
页码:193 / 203
页数:11
相关论文
共 8 条
[1]   The field-matching problem as it applies to the peacock three dimensional conformal system for intensity modulation [J].
Carol, M ;
Grant, WH ;
Bleier, AR ;
Kania, AA ;
Targovnik, HS ;
Butler, EB ;
Woo, SW .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 34 (01) :183-187
[2]   Commercial IMRT treatment-planning dose-calculation algorithm [J].
Low, DA ;
Mutic, S .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 41 (04) :933-937
[3]   Abutment region dosimetry for sequential arc IMRT delivery [J].
Low, DA ;
Mutic, S .
PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (07) :1465-1470
[4]   Quality assurance of serial tomotherapy for head and neck patient treatments [J].
Low, DA ;
Chao, KSC ;
Mutic, S ;
Gerber, RL ;
Perez, CA ;
Purdy, JA .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 42 (03) :681-692
[5]  
LOW DA, 1998, INT J RADIAT ONCOL, V40, P1465
[6]   Dosimetric verification of the dynamic intensity-modulated radiation therapy of 92 patients [J].
Tsai, JS ;
Wazer, DE ;
Ling, MN ;
Wu, JK ;
Fagundes, M ;
DiPetrillo, T ;
Kramer, B ;
Koistinen, M ;
Engler, MJ .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1998, 40 (05) :1213-1230
[7]   Initial experience with intensity-modulated conformal radiation therapy for treatment of the head and neck region [J].
Verellen, D ;
Linthout, N ;
VandenBerge, D ;
Bel, A ;
Storme, G .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1997, 39 (01) :99-114
[8]   Evaluation of dose calculation algorithm of the peacock system for multileaf intensity modulation collimator [J].
Wu, A ;
Johnson, M ;
Chen, ASJ ;
Kalnicki, S .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 36 (05) :1225-1231