Initial experience with intensity-modulated conformal radiation therapy for treatment of the head and neck region

被引:98
作者
Verellen, D
Linthout, N
VandenBerge, D
Bel, A
Storme, G
机构
[1] Free University Brussels (AZ-VUB), Academic Hospital, Department of Radiotherapy, Brussels
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 1997年 / 39卷 / 01期
关键词
conformal radiation therapy; intensity modulation; tomotherapy; patient positioning; film dosimetry; alanine dosimetry; multileaf collimator;
D O I
10.1016/S0360-3016(97)00304-0
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: The efficacy of a conventional, noninvasive fixation technique in combination with a commercially available system for conformal radiotherapy by intensity modulation of the treatment beam has been studied, Methods and Materials: A slice-by-slice are-rotation approach was used to deliver a conformal dose to the target and patient fixation was performed by means of thermoplastic casts, Eleven patients have been treated, of which 9 were for tumors of the head and neck region and 2 were for intracranial lesions. A procedure for target localization and verification of patient positioning suitable for this particular treatment technique has been developed based on the superposition of digitized portals with plots generated from the treatment-planning system, A dosimetric verification of the treatment procedure was performed with an anthropomorphic phantom: both absolute dose measurements (alanine and thermoluminescent detectors) and relative dose distribution measurements (film dosimetry) have been applied, The dose delivered outside the target has also been investigated. Results: The dose verification with the anthropomorphic phantom yielded a ratio between measured and predicted dose values of 1.0 for different treatment schedules and the calculated dose distribution agreed with the measured dose distribution, Day-to-day variations in patient setup of 0.3 cm (translations) and 2.0 degrees (rotations) were considered acceptable for this particular patient population, whereas the verification protocol allowed detection of 0.1 cm translational errors and 1.0 rotational errors, Conclusions: The noninvasive fixation technique in combination with an adapted verification protocol proved to be acceptable far conformal treatment of the head and neck region, Dose measurements, in turn, confirmed the predicted dose values to the target and organs at risk within uncertainty, Daily monitoring becomes mandatory if an accuracy superior to 0.1 cm and 1.0 degrees is required for patient setup, (C) 1997 Elsevier Science Inc.
引用
收藏
页码:99 / 114
页数:16
相关论文
共 60 条
[1]   SETUP DEVIATIONS IN WEDGED PAIR IRRADIATION OF PAROTID-GLAND AND TONSILLAR TUMORS, MEASURED WITH AN ELECTRONIC PORTAL IMAGING DEVICE [J].
BEL, A ;
KEUS, R ;
VIJLBRIEF, RE ;
LEBESQUE, JV .
RADIOTHERAPY AND ONCOLOGY, 1995, 37 (02) :153-159
[2]   METHODS OF IMAGE-RECONSTRUCTION FROM PROJECTIONS APPLIED TO CONFORMATION RADIOTHERAPY [J].
BORTFELD, T ;
BURKELBACH, J ;
BOESECKE, R ;
SCHLEGEL, W .
PHYSICS IN MEDICINE AND BIOLOGY, 1990, 35 (10) :1423-1434
[3]   X-RAY FIELD COMPENSATION WITH MULTILEAF COLLIMATORS [J].
BORTFELD, TR ;
KAHLER, DL ;
WALDRON, TJ ;
BOYER, AL .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1994, 28 (03) :723-730
[4]   USE OF ALANINE AS A SOLID DOSIMETER [J].
BRADSHAW, WW ;
SPETZLER, HA ;
CADENA, DG ;
CRAWFORD, GW .
RADIATION RESEARCH, 1962, 17 (01) :11-+
[5]   DESIGN PRINCIPLES AND CLINICAL POSSIBILITIES WITH A NEW GENERATION OF RADIATION-THERAPY EQUIPMENT - A REVIEW [J].
BRAHME, A .
ACTA ONCOLOGICA, 1987, 26 (06) :403-412
[6]   OPTIMIZATION OF STATIONARY AND MOVING BEAM RADIATION-THERAPY TECHNIQUES [J].
BRAHME, A .
RADIOTHERAPY AND ONCOLOGY, 1988, 12 (02) :129-140
[7]   Three dimensional conformal treatment planning with multileaf collimators [J].
Brewster, L ;
Mohan, R ;
Mageras, G ;
Burman, C ;
Leibel, S ;
Fuks, Z .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 33 (05) :1081-1089
[8]  
BUSHBERG JT, 1994, ESSENTIAL PHYSICS ME, P259
[9]  
CARL J, 1995, INTERNET WORLD, V6, P56
[10]   The field-matching problem as it applies to the peacock three dimensional conformal system for intensity modulation [J].
Carol, M ;
Grant, WH ;
Bleier, AR ;
Kania, AA ;
Targovnik, HS ;
Butler, EB ;
Woo, SW .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1996, 34 (01) :183-187