X-RAY FIELD COMPENSATION WITH MULTILEAF COLLIMATORS

被引:361
作者
BORTFELD, TR
KAHLER, DL
WALDRON, TJ
BOYER, AL
机构
[1] UNIV TEXAS,M D ANDERSON CANC CTR,DEPT RADIAT PHYS,HOUSTON,TX 77030
[2] DEUTSCH KREBSFORSCHUNGSZENTRUM,FORSCHUNGSSCHWERPUNKT RADIOL FS5,D-69120 HEIDELBERG,GERMANY
来源
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS | 1994年 / 28卷 / 03期
关键词
X-RAYS; COMPENSATION; CONFORMAL THERAPY; MULTILEAF COLLIMATORS;
D O I
10.1016/0360-3016(94)90200-3
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Purpose: It has been proposed that conformal therapy can be carried out with static ports that are each individually compensated to deliver an optimal total dose distribution. If this proposal is to be implemented, one must have a means of compensating or modulating the fluence distributions within the boundaries of individual treatment fields. A theory was developed and implemented to achieve this goal. Methods and Materials: The theory allowed creation of a leaf-setting sequence for a desired level of field-modulation precision. This method of beam modulation was experimentally verified using radiographic film to integrate the dose delivered by the sequence of discrete static multileaf collimator-defined subfields. Results: Beam profiles were generated that matched the planned beam profiles to within the specified degree of precision. Conclusion: This methodology is a candidate for implementation of inverse planning for conformal therapy.
引用
收藏
页码:723 / 730
页数:8
相关论文
共 23 条
[1]   METHODS OF IMAGE-RECONSTRUCTION FROM PROJECTIONS APPLIED TO CONFORMATION RADIOTHERAPY [J].
BORTFELD, T ;
BURKELBACH, J ;
BOESECKE, R ;
SCHLEGEL, W .
PHYSICS IN MEDICINE AND BIOLOGY, 1990, 35 (10) :1423-1434
[2]   POTENTIAL AND LIMITATIONS OF INVARIANT KERNEL CONFORMAL THERAPY [J].
BOYER, AL ;
DESOBRY, GE ;
WELLS, NH .
MEDICAL PHYSICS, 1991, 18 (04) :703-712
[3]   CONFORMATION THERAPY AT THE ROYAL FREE HOSPITAL - A PROGRESS REPORT ON THE TRACKING COBALT PROJECT [J].
BRACE, JA ;
DAVY, TJ ;
SKEGGS, DBL ;
WILLIAMS, HS .
BRITISH JOURNAL OF RADIOLOGY, 1981, 54 (648) :1068-1074
[4]   COMPUTER-CONTROLLED COBALT UNIT FOR RADIOTHERAPY [J].
BRACE, JA ;
DAVY, TJ ;
SKEGGS, DBL .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 1981, 19 (05) :612-616
[5]   OPTIMIZATION OF STATIONARY AND MOVING BEAM RADIATION-THERAPY TECHNIQUES [J].
BRAHME, A .
RADIOTHERAPY AND ONCOLOGY, 1988, 12 (02) :129-140
[6]   THE GENERATION OF INTENSITY-MODULATED FIELDS FOR CONFORMAL RADIOTHERAPY BY DYNAMIC COLLIMATION [J].
CONVERY, DJ ;
ROSENBLOOM, ME .
PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (06) :1359-1374
[7]  
Foley JD, 1982, FUNDAMENTALS INTERAC
[8]  
GREEN A, 1946, NATURE, V207, P1311
[9]  
JENNINGS WA, 1985, PROGR MED RAD PHYSIC, V2, P1
[10]   SHAPING OF ARBITRARY DOSE DISTRIBUTIONS BY DYNAMIC MULTILEAF COLLIMATION [J].
KALLMAN, P ;
LIND, B ;
EKLOF, A ;
BRAHME, A .
PHYSICS IN MEDICINE AND BIOLOGY, 1988, 33 (11) :1291-1300