Effect of color coding and subtraction on the accuracy of contrast echocardiography

被引:5
作者
Pasquet, A [1 ]
Greenberg, N [1 ]
Brunken, R [1 ]
Thomas, JD [1 ]
Marwick, TH [1 ]
机构
[1] Cleveland Clin Fdn, Dept Cardiol, Cleveland, OH 44195 USA
关键词
myocardial contrast echocardiography; SPECT; post processing;
D O I
10.1016/S0167-5273(99)00070-4
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Contrast echocardiography may be used to assess myocardial perfusion. However, gray scale assessment of myocardial contrast echocardiography (MCE) is difficult because of variations in regional backscatter intensity, difficulties in distinguishing varying shades of gray, and artifacts or attenuation. We sought to determine whether the assessment of rest myocardial perfusion by MCE could be improved with subtraction and color coding. Methods and results: MCE was performed in 31 patients with previous myocardial infarction with a 2(nd) generation agent (NC100100, Nycomed AS), using harmonic triggered or continuous imaging and gain settings were kept constant throughout the study. Digitized images were post processed by subtraction of baseline from contrast data and colorized to reflect the intensity of myocardial contrast. Gray scale MCE alone, MCE images combined with baseline and subtracted colorized images were scored independently using a 16 segment model. The presence and severity of myocardial contrast abnormalities were compared with perfusion defined by rest MIBI-SPECT. Segments that were not visualized by continuous (17%) or triggered imaging (14%) after color processing were excluded from further analysis. The specificity of gray scale MCE alone (56%) or MCE combined with baseline 2D (47%) was significantly enhanced by subtraction and color coding (76%, p<0.001) of triggered images. The accuracy of the gray scale approaches (respectively 52% and 47%) was increased to 70% (p<0.001). Similarly, for continuous images, the specificity of gray scale MCE with and without baseline comparison was 23% and 42% respectively, compared with 60% after post processing (p<0.001). The accuracy of colorized images (59%) was also significantly greater than gray scale MCE (43% and 29%, p<0.001). The sensitivity of MCE for both acquisitions was not altered by subtraction. Conclusion: Post-processing with subtraction and color coding significantly improves the accuracy and specificity of MCE for detection of perfusion defects. (C) 1999 Elsevier Science Ireland Ltd, All rights reserved.
引用
收藏
页码:223 / 231
页数:9
相关论文
共 20 条
[1]   REGIONAL HETEROGENEITY ON MYOCARDIAL CONTRAST ECHOCARDIOGRAPHY WITHOUT SEVERE OBSTRUCTIVE CORONARY-ARTERY DISEASE [J].
BACH, DS ;
MULLER, DWM ;
CHEIRIF, J ;
ARMSTRONG, WF .
AMERICAN JOURNAL OF CARDIOLOGY, 1995, 75 (15) :982-986
[2]  
BELLER GA, 1991, CIRCULATION, V84, pI1
[3]  
Block R J, 1996, J Am Soc Echocardiogr, V9, P787, DOI 10.1016/S0894-7317(96)90469-1
[4]   MYOCARDIAL CONTRAST ECHOCARDIOGRAPHY - ENHANCEMENT OF PERFUSION IMAGES BY COLOR CODING [J].
DAVILAROMAN, VG ;
BARZILAI, B .
JOURNAL OF CLINICAL ULTRASOUND, 1994, 22 (01) :21-27
[5]  
Halmann M, 1994, J Am Soc Echocardiogr, V7, P355
[6]  
Heo Jaekyeong, 1994, Cardiology Clinics, V12, P187
[7]  
Kaul S, 1997, CIRCULATION, V96, P785
[8]  
Keller M W, 1989, J Am Soc Echocardiogr, V2, P48
[9]   INCREMENTAL PROGNOSTIC POWER OF CLINICAL HISTORY, EXERCISE ELECTROCARDIOGRAPHY AND MYOCARDIAL PERFUSION SCINTIGRAPHY IN SUSPECTED CORONARY-ARTERY DISEASE [J].
LADENHEIM, ML ;
KOTLER, TS ;
POLLOCK, BH ;
BERMAN, DS ;
DIAMOND, GA .
AMERICAN JOURNAL OF CARDIOLOGY, 1987, 59 (04) :270-277
[10]   MYOCARDIAL PERFUSION IMAGING WITH TC-99M SESTAMIBI SPECT IN THE EVALUATION OF CORONARY-ARTERY DISEASE [J].
MADDAHI, J ;
KIAT, H ;
VANTRAIN, KF ;
PRIGENT, F ;
FRIEDMAN, J ;
GARCIA, EV ;
ALAZRAKI, N ;
DEPUEY, EG ;
NICHOLS, K ;
BERMAN, DS .
AMERICAN JOURNAL OF CARDIOLOGY, 1990, 66 (13) :E55-E62