MYOCARDIAL PERFUSION IMAGING WITH TC-99M SESTAMIBI SPECT IN THE EVALUATION OF CORONARY-ARTERY DISEASE

被引:116
作者
MADDAHI, J
KIAT, H
VANTRAIN, KF
PRIGENT, F
FRIEDMAN, J
GARCIA, EV
ALAZRAKI, N
DEPUEY, EG
NICHOLS, K
BERMAN, DS
机构
[1] CEDARS SINAI MED CTR,DEPT MED,DIV CARDIOL,LOS ANGELES,CA 90048
[2] CEDARS SINAI MED CTR,DEPT NUCL MED,LOS ANGELES,CA 90048
[3] UNIV CALIF LOS ANGELES,SCH MED,DEPT MED,LOS ANGELES,CA 90024
[4] EMORY UNIV,SCH MED,DEPT NUCL MED,ATLANTA,GA 30322
[5] ST LUKES ROOSEVELT HOSP,NEW YORK,NY 10025
关键词
D O I
10.1016/0002-9149(90)90613-6
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Technetium-99m (Tc-99m) sestamibi is a new myocardial perfusion imaging agent that offers significant advantages over thallium-201 (Tl-201) for myocardial perfusion imaging. The results of the current clinical trials using acquisition and processing parameters similar to those for Tl-201 and a separate (2-day) injection protocol suggest that Tc-99m sestamibi and Tl-201 single photon emission computed tomography (SPECT) provide similar information with respect to detection of myocardial perfusion defects, assessment of the pattern of defect reversibility, overall detection of coronary artery disease (CAD) and detection of disease in individual coronary arteries. Tc-99m sestamibi SPECT appears to be superior to Tc-99m sestamibi planar imaging because the former provides a higher defect contrast and is more accurate for detection of disease in individual coronary arteries. Research is currently under way addressing optimization of acquisition and processing of Tc-99m sestamibi studies and development of quantitative algorithms for detection and localization of CAD and sizing of transmural and nontransmural myocardial perfusion defects. It is expected that with the implementation of the final results of these new developments, further significant improvement in image quality will be attained, which in turn will further increase the confidence in image interpretation. Development of algorithms for analysis of end-diastolic myocardial images may allow better evaluation of small and nontransmural myocardial defects. Furthermore, gated studies may provide valuable information with respect to regional myocardial wall motion and wall thickening. With the implementation of algorithms for attenuation and scatter correction, the overall specificity of Tc-99m sestamibi SPECT should improve significantly because of a substantial decrease in the occurrence of attenuation-related image artifacts. Simultaneous assessment of ventricular function by performing first-pass studies may provide important additional information to that obtained from analysis of myocardial perfusion. © 1990.
引用
收藏
页码:E55 / E62
页数:8
相关论文
共 32 条
[1]  
BAILLET GY, 1989, J NUCL MED, V30, P38
[2]  
BERGIN J D, 1990, Journal of Nuclear Medicine, V31, P784
[3]   QUANTITATIVE ROTATIONAL TL-201 TOMOGRAPHY FOR IDENTIFYING AND LOCALIZING CORONARY-ARTERY DISEASE [J].
DEPASQUALE, EE ;
NODY, AC ;
DEPUEY, EG ;
GARCIA, EV ;
PILCHER, G ;
BREDLAU, C ;
ROUBIN, G ;
GOBER, A ;
GRUENTZIG, A ;
DAMATO, P ;
BERGER, HJ .
CIRCULATION, 1988, 77 (02) :316-327
[4]   APPLICATION OF CONDITIONAL-PROBABILITY ANALYSIS TO THE CLINICAL-DIAGNOSIS OF CORONARY-ARTERY DISEASE [J].
DIAMOND, GA ;
FORRESTER, JS ;
HIRSCH, M ;
STANILOFF, HM ;
VAS, R ;
BERMAN, DS ;
SWAN, HJC .
JOURNAL OF CLINICAL INVESTIGATION, 1980, 65 (05) :1210-1221
[5]   ANALYSIS OF PROBABILITY AS AN AID IN THE CLINICAL-DIAGNOSIS OF CORONARY-ARTERY DISEASE [J].
DIAMOND, GA ;
FORRESTER, JS .
NEW ENGLAND JOURNAL OF MEDICINE, 1979, 300 (24) :1350-1358
[6]   IMPROVED DIAGNOSTIC PERFORMANCE OF EXERCISE TL-201 SINGLE PHOTON-EMISSION COMPUTED-TOMOGRAPHY OVER PLANAR IMAGING IN THE DIAGNOSIS OF CORONARY-ARTERY DISEASE - A RECEIVER OPERATING CHARACTERISTIC ANALYSIS [J].
FINTEL, DJ ;
LINKS, JM ;
BRINKER, JA ;
FRANK, TL ;
PARKER, M ;
BECKER, LC .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1989, 13 (03) :600-612
[7]  
FOLKS R, 1989, Journal of Nuclear Medicine, V30, P795
[8]  
GALT J, 1988, RECONSTRUCTION ABSOL
[9]   TECHNICAL ASPECTS OF MYOCARDIAL SPECT IMAGING WITH TC-99M SESTAMIBI [J].
GARCIA, EV ;
COOKE, CD ;
VANTRAIN, KF ;
FOLKS, R ;
PEIFER, J ;
DEPUEY, EG ;
MADDAHI, J ;
ALAZRAKI, N ;
GALT, J ;
EZQUERRA, N ;
ZIFFER, J ;
AREEDA, J ;
BERMAN, DS .
AMERICAN JOURNAL OF CARDIOLOGY, 1990, 66 (13) :E23-E31
[10]   FEASIBILITY OF TOMOGRAPHIC TC-99M-HEXAKIS-2-METHOXY-2-METHYLPROPYL-ISONITRILE IMAGING FOR THE ASSESSMENT OF MYOCARDIAL AREA AT RISK AND THE EFFECT OF TREATMENT IN ACUTE MYOCARDIAL-INFARCTION [J].
GIBBONS, RJ ;
VERANI, MS ;
BEHRENBECK, T ;
PELLIKKA, PA ;
OCONNOR, MK ;
MAHMARIAN, JJ ;
CHESEBRO, JH ;
WACKERS, FJ .
CIRCULATION, 1989, 80 (05) :1277-1286