Root canal cleanliness after preparation with different endodontic handpieces and hand instruments: A comparative SEM investigation

被引:214
作者
Hulsmann, M
Rummelin, C
Schafers, F
机构
[1] Department of Operative Dentistry, University of Göttingen
[2] Department of Operative Dentistry, University of Göttingen, D-37075 Göttingen
关键词
D O I
10.1016/S0099-2399(97)80410-4
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
The root canals of 150 extracted mandibular incisors were prepared to ISO 30 using eight different automated devices and hand instruments, The automated devices investigated were: Endoplaner, Excalibur, Ultrasonics (Piezon Master 400) with H2O2 (5%), or NaOCl (1%) as irrigants, Giromatic, Intra-Endo 3-LDSY, Canal Finder System, Canal Leader 2000, and Endolift, Hand instrumentation was performed using reamers and Hedstroem files, Fifteen teeth were instrumented with each device, cracked longitudinally, and investigated under the scanning electron microscope using five category scoring systems based on reference photographs for debris and smear layer, No preparation system or technique resulted in complete removal of smear layer and debris, The ultrasonic unit performed best followed by the Canal Leader 2000 and hand instrumentation, whereas the use of the Giromatic, the Endolift, the Canal Finder System, and the Intra-Endo-3-LDSY-handpiece resulted in insufficiently cleaned root canal walls.
引用
收藏
页码:301 / 306
页数:6
相关论文
共 20 条
[11]  
HULSMANN M, 1993, ENDODONTIE ERKENNTNI
[12]   AN EVALUATION OF A NEW MECHANIZED ENDODONTIC DEVICE - THE ENDOLIFT [J].
LEHMAN, JW ;
GERSTEIN, H .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1982, 53 (04) :417-424
[13]   CLEANING OF OVAL CANALS USING ULTRASONIC OR SONIC INSTRUMENTATION [J].
LUMLEY, PJ ;
WALMSLEY, AD ;
WALTON, RE ;
RIPPIN, JW .
JOURNAL OF ENDODONTICS, 1993, 19 (09) :453-457
[14]   EVALUATION OF ROOT CANAL PREPARATION WITH 2 AUTOMATED ENDODONTIC HANDPIECES [J].
OCONNELL, DT ;
BRAYTON, SM .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1975, 39 (02) :298-303
[15]   SCANNING ELECTRON-MICROSCOPIC EVALUATION OF DIFFERENT ENDODONTIC PROCEDURES ON DENTIN MORPHOLOGY OF HUMAN TEETH [J].
PRATI, C ;
SELIGHINI, M ;
FERRIERI, P ;
MONGIORGI, R .
JOURNAL OF ENDODONTICS, 1994, 20 (04) :174-179
[16]  
Rollinger J, 1990, Dtsch Zahnarztl Z, V45, P748
[17]  
Schadle C W, 1990, Schweiz Monatsschr Zahnmed, V100, P274
[18]   A LIGHT MICROSCOPIC STUDY OF THE EFFICACY OF THE TELESCOPIC AND THE GIROMATIC PREPARATION OF ROOT CANALS [J].
TUREK, T ;
LANGELAND, K .
JOURNAL OF ENDODONTICS, 1982, 8 (10) :437-443
[19]  
Velvart P, 1987, Schweiz Monatsschr Zahnmed, V97, P756
[20]  
Weine F S, 1976, J Endod, V2, P298, DOI 10.1016/S0099-2399(76)80044-1