Assessment of a single-acquisition imaging sequence for oxygen-sensitive 3He-MRI

被引:66
作者
Deninger, AJ
Eberle, B
Bermuth, J
Escat, B
Markstaller, K
Schmiedeskamp, J
Schreiber, WG
Surkau, R
Otten, E
Kauczor, HU
机构
[1] Univ Mainz, Sch Med, Dept Anesthesiol, D-55101 Mainz, Germany
[2] Univ Mainz, Dept Phys, D-6500 Mainz, Germany
[3] Univ Mainz, Dept Radiol, D-6500 Mainz, Germany
关键词
hyperpolarized gas MRI; functional MRI; helium-3; MRI of pulmonary ventilation; oxygen partial pressure;
D O I
10.1002/mrm.10032
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
MRI of the lungs using hyperpolarized helium-3 (He-3) allows the determination of intrapulmonary oxygen partial pressures (p(O2)). The need to separate competing processes of signal loss has hitherto required two different imaging series during two different breathing maneuvers. In this work, a new imaging strategy to measure p(O2) by a single series of consecutive scans is presented. The feasibility of the method is demonstrated in three healthy human volunteers. Maps and histograms of intrapulmonary p(O2) are calculated. Changes in the oxygen concentration of the inhaled gas mixture are well reproduced in the histograms. Monte Carlo (MC) simulations of the temporal evolution of 3He hyperpolarization within the lungs were performed to evaluate the accuracy of this measurement technique, and its limitations. Magn Reson Med 47:105-114, 2002. (C) 2002 Wiley-Liss, Inc.
引用
收藏
页码:105 / 114
页数:10
相关论文
共 32 条
[1]  
BRANDT L, 1989, ANAESTHESIST, V38, P167
[2]  
Chen XJ, 1999, MAGNET RESON MED, V42, P721, DOI 10.1002/(SICI)1522-2594(199910)42:4<721::AID-MRM14>3.0.CO
[3]  
2-D
[4]   Lung air spaces:: MR imaging evaluation with hyperpolarized 3He gas [J].
de Lange, EE ;
Mugler, JP ;
Brookeman, JR ;
Knight-Scott, J ;
Truwit, JD ;
Teates, CD ;
Daniel, TM ;
Bogorad, PL ;
Cates, GD .
RADIOLOGY, 1999, 210 (03) :851-857
[5]  
Deninger AJ, 2000, NMR BIOMED, V13, P194, DOI 10.1002/1099-1492(200006)13:4<194::AID-NBM643>3.0.CO
[6]  
2-D
[7]   Quantification of regional intrapulmonary oxygen partial pressure evolution during apnea by 3He MRI [J].
Deninger, AJ ;
Eberle, B ;
Ebert, M ;
Grossmann, T ;
Heil, W ;
Kauczor, HU ;
Lauer, L ;
Markstaller, K ;
Otten, E ;
Schmiedeskamp, J ;
Schreiber, W ;
Surkau, R ;
Thelen, M ;
Weiler, N .
JOURNAL OF MAGNETIC RESONANCE, 1999, 141 (02) :207-216
[8]  
DENINGER AJ, 2000, THESIS U MAINZ GERMA
[9]   Analysis of intrapulmonary O2 concentration by NIR imaging of inhaled hyperpolarized helium-3 [J].
Eberle, B ;
Weiler, N ;
Markstaller, K ;
Kauczor, HU ;
Deninger, A ;
Ebert, M ;
Grossmann, T ;
Heil, W ;
Lauer, LO ;
Roberts, TPL ;
Schreiber, WG ;
Surkau, R ;
Dick, WF ;
Otten, EW ;
Thelen, M .
JOURNAL OF APPLIED PHYSIOLOGY, 1999, 87 (06) :2043-2052
[10]  
EBERLE B, 2000, THESIS U MAINZ GERMA