Comparison of results of intracoronary implantation of the Palmaz-Schatz stent with conventional balloon angioplasty in chronic total coronary arterial occlusion

被引:35
作者
Mori, M [1 ]
Kurogane, H [1 ]
Hayashi, T [1 ]
Yasaka, Y [1 ]
Ohta, S [1 ]
Kajiya, T [1 ]
Takarada, A [1 ]
Yoshida, A [1 ]
Matsuda, Y [1 ]
Nakagawa, K [1 ]
Murata, T [1 ]
Yoshida, Y [1 ]
Yokoyama, M [1 ]
机构
[1] KOBE UNIV,SCH MED,DEPT INTERNAL MED 1,KOBE 650,JAPAN
关键词
D O I
10.1016/S0002-9149(96)00521-8
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We compared angiographic and clinical outcomes after successful revascularization of chronic total coronary arterial occlusion with the placement of the Palmaz-Schatz stent (43 patients) and conventional balloon angioplasty (53 patients). After the procedure, the coronary stent led to a greater minimal lumen diameter than conventional balloon angioplasty (2.6 vs 1.7 mm, p < 0.001), resulting in a smeller residual stenosis (6.5% vs 36.7%, p < 0.001). At 6-month follow-up, there was no significant difference in late loss between the groups, resulting in a larger minimal lumen diameter at follow-up in the stent group (1.8 vs 1.1 mm, p < 0.001). The incidence of restenosis was lower in the stent group (27.9% vs 56.6%, p < 0.005). The frequency of the combination of myocardial infarction and coronary artery bypass graft surgery tended to be less in the stent group (2.3% vs 11.3%, p = 0.09). Placement of the Palmaz-Schatz stent improved left ventricular ejection fraction by 26% in patients who had reduced left ventricular function (p < 0.05), but conventional balloon angioplasty did not. Thus, placement of the Palmaz-Schatz stent provided a wider lumen than did conventional balloon angioplasty and, therefore, reduced the incidence of restenosis in chronic total coronary arterial occlusion. The lower restenosis rate of coronary stenting would be beneficial for long-term clinical outcome in patients with chronic total occlusion. (C) 1996 by Excerpta Medica, Inc.
引用
收藏
页码:985 / 989
页数:5
相关论文
共 23 条
  • [1] CLINICAL SUCCESS, COMPLICATIONS AND RESTENOSIS RATES WITH EXCIMER LASER CORONARY ANGIOPLASTY
    BITTL, JA
    SANBORN, TA
    TCHENG, JE
    SIEGEL, RM
    ELLIS, SG
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1992, 70 (20) : 1533 - 1539
  • [2] RESTENOSIS AFTER PLACEMENT OF PALMAZ-SCHATZ STENTS IN NATIVE CORONARY-ARTERIES - INITIAL RESULTS OF A MULTICENTER EXPERIENCE
    ELLIS, SG
    SAVAGE, M
    FISCHMAN, D
    BAIM, DS
    LEON, M
    GOLDBERG, S
    HIRSHFELD, JW
    CLEMAN, MW
    TEIRSTEIN, PS
    WALKER, C
    BAILEY, S
    BUCHBINDER, M
    TOPOL, EJ
    SCHATZ, RA
    [J]. CIRCULATION, 1992, 86 (06) : 1836 - 1844
  • [3] FISHMAN DL, 1994, NEW ENGL J MED, V331, P496
  • [4] QUANTITATIVE-ANALYSIS OF ELASTIC RECOIL AFTER BALLOON ANGIOPLASTY AND AFTER INTRACORONARY IMPLANTATION OF BALLOON-EXPANDABLE PALMAZ-SCHATZ STENTS
    HAUDE, M
    ERBEL, R
    ISSA, H
    MEYER, J
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 21 (01) : 26 - 34
  • [5] PERCUTANEOUS TRANSLUMINAL CORONARY ANGIOPLASTY OF CHRONIC TOTAL OCCLUSIONS - PRIMARY SUCCESS, RESTENOSIS, AND LONG-TERM CLINICAL FOLLOW-UP
    IVANHOE, RJ
    WEINTRAUB, WS
    DOUGLAS, JS
    LEMBO, NJ
    FURMAN, M
    GERSHONY, G
    COHEN, CL
    KING, SB
    [J]. CIRCULATION, 1992, 85 (01) : 106 - 115
  • [6] CORONARY ANGIOPLASTY OF CHRONIC TOTAL OCCLUSIONS WITH BRIDGING COLLATERAL VESSELS - IMMEDIATE AND FOLLOW-UP OUTCOME FROM A LARGE SINGLE-CENTER EXPERIENCE
    KINOSHITA, I
    KATOH, O
    NARIYAMA, J
    OTSUJI, S
    TATEYAMA, H
    KOBAYASHI, T
    SHIBATA, N
    ISHIHARA, T
    OHSAWA, N
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1995, 26 (02) : 409 - 415
  • [7] THE IMPORTANCE OF ACUTE LUMINAL DIAMETER IN DETERMINING RESTENOSIS AFTER CORONARY ATHERECTOMY OR STENTING
    KUNTZ, RE
    SAFIAN, RD
    CARROZZA, JP
    FISHMAN, RF
    MANSOUR, M
    BAIM, DS
    [J]. CIRCULATION, 1992, 86 (06) : 1827 - 1835
  • [8] GENERALIZED-MODEL OF RESTENOSIS AFTER CONVENTIONAL BALLOON ANGIOPLASTY, STENTING AND DIRECTIONAL ATHERECTOMY
    KUNTZ, RE
    GIBSON, CM
    NOBUYOSHI, M
    BAIM, DS
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 21 (01) : 15 - 25
  • [9] AUTOMATED QUANTITATIVE CORONARY ARTERIOGRAPHY - MORPHOLOGICAL AND PHYSIOLOGICAL VALIDATION IN VIVO OF A RAPID DIGITAL ANGIOGRAPHIC METHOD
    MANCINI, GBJ
    SIMON, SB
    MCGILLEM, MJ
    LEFREE, MT
    FRIEDMAN, HZ
    VOGEL, RA
    [J]. CIRCULATION, 1987, 75 (02) : 452 - 460
  • [10] Lusitropic effects of a Ca2+ sensitization with a new cardiotonic agent MCI-154, on diseased human hearts