An incident-beam monitor for use in protein crystallography at a synchrotron source

被引:9
作者
Alkire, RW
Rotella, FJ
机构
[1] Ctr. Mechanistic Biol. and Biotech., Argonne National Laboratory, Argonne
关键词
D O I
10.1107/S002188989601401X
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A compact incident-beam monitor has been developed for use in synchrotron protein crystallography at the National Synchrotron Light Source beamline X8C. Incident-beam intensity is monitored by measurement of the radiation scattered from a thin polymer film into a PIN diode. For improved statistical accuracy, the scattering film can be replaced by a thin metal foil. Fluorescent radiation emitted by the metal foil increases the beam-monitoring signal up to 50 times relative to that produced by scattering alone. With this design, the forward-scattered radiation is restricted to an area not larger than the beam stop, minimizing excessive background radiation. Support materials have been optimized so that no unwanted edge effects are present between 6 and 19.5 keV, making the detector useful for monitoring incident-beam intensities over the wide range of absorption edges often associated with multiwavelength anomalous diffraction (MAD) experiments. Accurate incident-beam monitoring also simplifies optimization of the X-ray beam through the diffractometer collimation after each new electron orbit is established in the synchrotron.
引用
收藏
页码:327 / 332
页数:6
相关论文
共 16 条
[1]   THE X8C DUAL WIRE BEAM POSITION MONITOR [J].
ALKIRE, RW ;
SULLIVAN, EP ;
MICHAUD, FD ;
TRELA, WJ ;
BARTLETT, RJ .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 350 (1-2) :13-16
[2]   PERFORMANCE OF BEAMLINE X8C AT THE NSLS [J].
ALKIRE, RW ;
SAGURTON, M ;
MICHAUD, FD ;
TRELA, WJ ;
BARTLETT, RJ ;
ROTHE, R .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1995, 352 (03) :535-541
[3]   AN OPTIMIZED COLLIMATOR FOR X-RAY-DIFFRACTION FROM VERY SMALL SAMPLES USING SYNCHROTRON RADIATION [J].
BARTUNIK, HD ;
GEHRMANN, T ;
ROBRAHN, B .
JOURNAL OF APPLIED CRYSTALLOGRAPHY, 1984, 17 (APR) :120-120
[4]   MONITORING OF THE X-RAY-BEAM INTENSITY GOING THROUGH A COLLIMATOR USING A SMALL IONIZATION-CHAMBER [J].
BOSSHARD, R ;
KAHN, R ;
FOURME, R .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (01) :810-813
[5]   SILICON PHOTODIODE DETECTOR FOR FLUORESCENCE EXAFS [J].
BOULDIN, CE ;
FORMAN, RA ;
BELL, MI .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1987, 58 (10) :1891-1894
[6]  
CAUCHOIS Y, 1978, WAVELENTHS XRAY EMIS, V18
[7]   SYNCHROTRON X-RAY-DIFFRACTION FROM A 800 MU-M ZEOLITE MICROCRYSTAL [J].
EISENBERGER, P ;
NEWSAM, JM ;
LEONOWICZ, ME ;
VAUGHAN, DEW .
NATURE, 1984, 309 (5963) :45-47
[8]   PIN DIODES AS DETECTORS IN THE ENERGY REGION 500 EV-10 KEV [J].
JACH, T ;
COWAN, PL .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1983, 208 (1-3) :423-425
[9]   SILICON PHOTODIODE DETECTOR FOR SMALL-ANGLE X-RAY-SCATTERING [J].
JEMIAN, PR ;
LONG, GG .
JOURNAL OF APPLIED CRYSTALLOGRAPHY, 1990, 23 :430-432
[10]   PIN DIODE DETECTORS FOR SYNCHROTRON X-RAYS [J].
KIRKLAND, JP ;
JACH, T ;
NEISER, RA ;
BOULDIN, CE .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 266 (1-3) :602-607