Chitosan/polyaniline hybrid conducting biopolymer base impedimetric immunosensor to detect Ochratoxin-A

被引:98
作者
Khan, Raju [2 ]
Dhayal, Marshal [1 ]
机构
[1] Univ Washington, Dept Bioengn, Seattle, WA 98195 USA
[2] NE Inst Sci & Technol, Jorhat 785006, Assam, India
关键词
Polyaniline; Chitosan; Immunosensor; Electrochemical impedance spectroscopy; Ochratoxin-A; ELECTROCHEMICAL IMPEDANCE SPECTROSCOPY; HORSERADISH-PEROXIDASE IMMOBILIZATION; PERFORMANCE LIQUID-CHROMATOGRAPHY; GOLD NANOPARTICLES; BIOMOLECULAR IMMOBILIZATION; COMPOSITE FILM; HUMAN-BLOOD; BIOSENSOR; AFLATOXIN; CHITOSAN;
D O I
10.1016/j.bios.2008.08.046
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Chitosam (CS)-polyaniline (PANI) hybrid conducting biopolymer film was obtained on indium-tin-oxide (ITO) electrode using electrochemical polymerization process. Fourier transform infrared (FT-IR) spectra of PANI-CS had showed covalent and hydrogen binding between PANI and CS molecules. Electrochemical impedance spectroscopy (EIS) measurements had showed low charge transfer resistance (R-CT) of PANI-CS and PANI. Successive rabbitantibody (IgGs) immobilization on PANI-CS, CS and PANI matrixes surface were confirmed with FT-IR and EIS measurements. Ochratoxin-A (OTA) interaction with IgGs had increased R-CT values and showed linear response up to 10 ng/mL OTA concentration in electrolyte. Relative change in R-CT was higher in PANI-CS due to higher proportion of carboxylic and hydroxyl functionalities at PANI-CS matrix surfaces. The absolute sensitivity of PANI, CS, and PANI-CS were 16 +/- 6, 22 +/- 9 and 53 +/- 8 Omega mL/ng, respectively derived from slope of linear response up to 10 ng/mL with I ng/mL minimum detection limit. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:1700 / 1705
页数:6
相关论文
共 38 条
[11]   OCHRATOXIN-A IN HUMAN-BLOOD AND BALKAN ENDEMIC NEPHROPATHY [J].
HULT, K ;
PLESTINA, R ;
HABAZINNOVAK, V ;
RADIC, B ;
CEOVIC, S .
ARCHIVES OF TOXICOLOGY, 1982, 51 (04) :313-321
[12]   Synthesis of porous titania microspheres for HPLC packings by polymerization-induced colloid aggregation (PICA) [J].
Jiang, ZT ;
Zuo, YM .
ANALYTICAL CHEMISTRY, 2001, 73 (03) :686-688
[13]   Nanocrystalline bioactive TiO2-chitosan impedimetric immunosensor for ochratoxin-A [J].
Khan, Raju ;
Dhayal, Marshal .
ELECTROCHEMISTRY COMMUNICATIONS, 2008, 10 (03) :492-495
[14]   Electrochemical studies of novel chitosan/TiO2 bioactive electrode for biosensing application [J].
Khan, Raju ;
Dhayal, Marshal .
ELECTROCHEMISTRY COMMUNICATIONS, 2008, 10 (02) :263-267
[15]   Conducting poly(3,4-alkylenedioxythiophene) derivatives as fast electrochromics with high-contrast ratios [J].
Kumar, A ;
Welsh, DM ;
Morvant, MC ;
Piroux, F ;
Abboud, KA ;
Reynolds, JR .
CHEMISTRY OF MATERIALS, 1998, 10 (03) :896-902
[16]   Nanosized flower-like ZnO synthesized by a simple hydrothermal method and applied as matrix for horseradish peroxidase immobilization for electro-biosensing [J].
Liu, YL ;
Yang, YH ;
Yang, HF ;
Liu, ZM ;
Shen, GL ;
Yu, RQ .
JOURNAL OF INORGANIC BIOCHEMISTRY, 2005, 99 (10) :2046-2053
[17]   DNA arrays, electronic noses and tongues, biosensors and receptors for rapid detection of toxigenic fungi and mycotoxins: A review [J].
Logrieco, A ;
Arrigan, DWM ;
Brengel-Pesce, K ;
Siciliano, P ;
Tothill, I .
FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2005, 22 (04) :335-344
[18]   Electrochemically deposited chitosan hydrogel for horseradish peroxidase immobilization through gold nanoparticles self-assembly [J].
Luo, XL ;
Xu, JJ ;
Zhang, Q ;
Yang, GJ ;
Chen, HY .
BIOSENSORS & BIOELECTRONICS, 2005, 21 (01) :190-196
[19]   A glucose biosensor based on chitosan-glucose oxidase-gold nanoparticles biocomposite formed by one-step electrodeposition [J].
Luo, XL ;
Xu, JJ ;
Du, Y ;
Chen, HY .
ANALYTICAL BIOCHEMISTRY, 2004, 334 (02) :284-289
[20]   THE CONCEPT OF SECONDARY DOPING AS APPLIED TO POLYANILINE [J].
MACDIARMID, AG ;
EPSTEIN, AJ .
SYNTHETIC METALS, 1994, 65 (2-3) :103-116