Critical factors for the performance of chip array-based electrical detection of DNA for analysis of pathogenic bacteria

被引:11
作者
Liu, Yanling
Elsholz, Bruno [2 ]
Enfors, Sven-Olof
Gabig-Ciminska, Magdalena [1 ,3 ]
机构
[1] Royal Inst Technol KTH, Dept Biotechnol, Sch Biotechnol, S-10691 Stockholm, Sweden
[2] Frounhofer Inst Silicon Technol, D-25524 Itzehoe, Germany
[3] Univ Gdansk, Polish Acad Sci, Inst Biochem & Biophys, Mol Biol Lab, PL-80822 Gdansk, Poland
基金
瑞典研究理事会;
关键词
electrical chip arrays; nucleic acid-based analysis; toxin-encoding genes; bacterial pathogenicity; Bacillus cereus;
D O I
10.1016/j.ab.2008.05.057
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Different factors influencing chip array-based electrical detection of DNA for analysis of pathogenic bacteria were examined. Both rehydration of capture probe layer of functionalized chip arrays and efficient hybridization of targets irrespective of their length resulted in signal enhancement when high-ionic phosphate-buffered saline (i.e., 600 mM sodium chloride and 40 mM disodium hydrogen phosphate) was used. Similarly, placement of two adjacent capture and detection probe-binding sites at a terminal part of the target strand resulted in significant signal increase. Moreover, 10-min ultrasonic fragmentation of targets amplified the signals Lip to twofold for longer DNA strands (i.e., >300 bp). No obvious effects on signals were visible for shorter than 400-bp PCR amplicons subjected to ultrasonication. For DNA strands of all sizes, more than 10 min ultrasonication diminished the specific electrical responses. Our results also demonstrate that target analytes are detected with discrimination against mismatches even for single nucleotide sequence alteration. The mismatch detection appeared in order of ease Of recognition as follows: triple random > quintuple middle > triple middle > single middle mismatch. Among the three variants of one-base mismatches, a sequence variation was most remarkable for adenine. On the other hand, no benefits in assay sensitivity were recognized by the use of longer capture probe linkers as the 6-C linker. (C) 2008 Elsevier Inc. All rights reserved.
引用
收藏
页码:77 / 86
页数:10
相关论文
共 25 条
[1]   A DNA self-assembled monolayer for the specific attachment of unmodified double- or single-stranded DNA [J].
Bamdad, C .
BIOPHYSICAL JOURNAL, 1998, 75 (04) :1997-2003
[2]   Effect of unlabeled helper probes on detection of an RNA target by bead-based sandwich hybridization [J].
Barken, KB ;
Gabig-Ciminska, M ;
Holmgren, A ;
Molin, S .
BIOTECHNIQUES, 2004, 36 (01) :124-+
[3]   Detection of bacterial pathogens in environmental samples using DNA microarrays [J].
Call, DR ;
Borucki, MK ;
Loge, FJ .
JOURNAL OF MICROBIOLOGICAL METHODS, 2003, 53 (02) :235-243
[4]  
DEISINGH A, 2003, MICROBIOLOGIST, P30
[5]   Biosensors for the detection of bacteria [J].
Deisingh, AK ;
Thompson, M .
CANADIAN JOURNAL OF MICROBIOLOGY, 2004, 50 (02) :69-77
[6]   Automated detection and quantitation of bacterial RNA by using electrical microarrays [J].
Elsholz, B. ;
Woerl, R. ;
Blohm, L. ;
Albers, J. ;
Feucht, H. ;
Grunwald, T. ;
Juergen, B. ;
Schweder, T. ;
Hintsche, Rainer .
ANALYTICAL CHEMISTRY, 2006, 78 (14) :4794-4802
[7]  
ELSHOLZ B, 2007, THESIS EM ARNDT U GR
[8]   Design and application of an oligonucleotide microarray for the investigation of compost microbial communities [J].
Franke-Whittle, IH ;
Klammer, SH ;
Insam, H .
JOURNAL OF MICROBIOLOGICAL METHODS, 2005, 62 (01) :37-56
[9]   Gene-based identification of bacterial colonies with an electric chip [J].
Gabig-Ciminska, M ;
Liu, YL ;
Enfors, SO .
ANALYTICAL BIOCHEMISTRY, 2005, 345 (02) :270-276
[10]   Electric chips for rapid detection and quantification of nucleic acids [J].
Gabig-Ciminska, M ;
Holmgren, A ;
Andresen, H ;
Barken, KB ;
Wümpelmann, M ;
Albers, J ;
Hintsche, R ;
Breitenstein, A ;
Neubauer, P ;
Los, M ;
Czyz, A ;
Wegrzyn, G ;
Silfversparre, G ;
Jürgen, B ;
Schweder, T ;
Enfors, SO .
BIOSENSORS & BIOELECTRONICS, 2004, 19 (06) :537-546