Endoleaks after Endovascular Abdominal Aortic Aneurysm Repair: Detection with Dual-Energy Dual-Source CT

被引:170
作者
Stolzmann, Paul [1 ]
Frauenfelder, Thomas [1 ]
Pfammatter, Thomas [1 ]
Peter, Nicole [1 ]
Scheffel, Hans [1 ]
Lachat, Mario [2 ]
Schmidt, Bernhard [3 ]
Marincek, Borut [1 ]
Alkadhi, Hatem [1 ]
Schertler, Thomas [1 ]
机构
[1] Univ Zurich Hosp, Inst Diagnost Radiol, CH-8091 Zurich, Switzerland
[2] Univ Zurich Hosp, Cardiovasc Surg Clin, CH-8091 Zurich, Switzerland
[3] Siemens Med Solut, Forchheim, Germany
基金
瑞士国家科学基金会;
关键词
D O I
10.1148/radiol.2483080193
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To assess the diagnostic performance of dual-energy dual-source computed tomography (CT) in the detection of endoleaks after endovascular abdominal aortic aneurysm (AAA) repair. Materials and Methods: This study was local ethics board approved, and written informed consent was obtained from all patients. One hundred eighteen patients ( 21 women, 97 men; mean age, 74 years +/- 8 [ standard deviation]) underwent follow-up dual-energy dual-source CT during the nonenhanced, arterial, and delayed phases after AAA repair. Delayed phase CT images were acquired in the dual-energy mode for reconstruction of virtual nonenhanced images. Two blinded and independent readers evaluated the data for the presence or absence of endoleaks during three reading sessions: Standard nonenhanced, arterial phase, and delayed phase images were read during session A; virtual nonenhanced, arterial phase, and delayed phase images, during session B; and virtual nonenhanced and delayed phase images, during session C. Sensitivity, specificity, negative predictive value (NPV), and positive predictive value (PPV) were calculated, with the session A image data set as the reference standard. Radiation dose parameters were estimated. Results: Reading session A revealed that 52 (44%) of 118 patients had endoleaks. Overall sensitivity, specificity, NPV, and PPV for CT endoleak detection during sessions B and C were identical: 100%, 97%, 100%, and 96%, respectively. The accuracy of the session B and session C readings was not significantly different from that of the session A reading (P = .50). The effective radiation dose in the image acquisition protocol involving one dual-energy scan was significantly (P < .001) lower than the effective doses in the protocols involving standard triple-phase scanning (mean difference, 61%) and standard nonenhanced and delayed phase scanning (mean difference, 41%). Conclusion: Compared with standard protocols, one dual-energy dual-source CT scan performed during the delayed phase with reconstruction of virtual nonenhanced images enables detection of endoleaks after endovascular AAA repair with high accuracy and a considerably lower radiation dose. (c) RSNA, 2008
引用
收藏
页码:682 / 691
页数:10
相关论文
共 31 条
  • [1] Emergency endovascular repair for ruptured abdominal aortic aneurysms: Feasibility and comparison of early results with conventional open repair
    Alsac, JM
    Desgranges, P
    Kobeiter, H
    Becquemin, JP
    [J]. EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2005, 30 (06) : 632 - 639
  • [2] CLINICAL APPLICATION OF COMPTON AND PHOTOELECTRIC RECONSTRUCTION IN COMPUTED TOMOGRAPHY - PRELIMINARY-RESULTS
    AVRIN, DE
    MACOVSKI, A
    ZATZ, LM
    [J]. INVESTIGATIVE RADIOLOGY, 1978, 13 (03) : 217 - 222
  • [3] Endoluminal stent-grafts for infrarenal abdominal aortic aneurysms
    Blum, U
    Voshage, G
    Lammer, J
    Beyersdorf, F
    Tollner, D
    Kretschmer, G
    Spillner, G
    Polterauer, P
    Nagel, G
    Holzenbein, T
    Thurnher, S
    Langer, M
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1997, 336 (01) : 13 - 20
  • [4] Endovascular versus open surgical elective repair of infrarenal abdominal aortic aneurysm: Predictors of patient discharge destination
    Bosch, JL
    Beinfeld, MT
    Halpern, EF
    Lester, JS
    Gazelle, GS
    [J]. RADIOLOGY, 2001, 220 (03) : 576 - 580
  • [5] Estimated radiation risks potentially associated with full-body CT screening
    Brenner, DJ
    Elliston, CD
    [J]. RADIOLOGY, 2004, 232 (03) : 735 - 738
  • [6] First performance evaluation of a dual-source CT (DSCT) system
    Flohr, TG
    McCollough, CH
    Bruder, H
    Petersilka, M
    Gruber, K
    Süss, C
    Grasruck, M
    Stierstorfer, K
    Krauss, B
    Raupach, R
    Primak, AN
    Küttner, A
    Achenbach, S
    Becker, C
    Kopp, A
    Ohnesorge, BM
    [J]. EUROPEAN RADIOLOGY, 2006, 16 (02) : 256 - 268
  • [7] Techniques and parameters for estimating radiation exposure and dose in cardiac computed tomography
    Gerber, TC
    Kuzo, RS
    Morin, RL
    [J]. INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2005, 21 (01) : 165 - 176
  • [8] Helical CT of aorta after endoluminal stent-graft therapy: Value of biphasic acquisition
    Golzarian, J
    Dussaussois, L
    Abada, HT
    Gevenois, PA
    Van Gansbeke, D
    Ferreira, J
    Struyven, J
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 171 (02) : 329 - 331
  • [9] Endovascular aortic stent-grafts: Transcatheter embolization of persistent perigraft leaks
    Golzarian, J
    Struyven, J
    Abada, HT
    Wery, D
    Dussaussois, L
    Madani, A
    Ferreira, J
    Dereume, JP
    [J]. RADIOLOGY, 1997, 202 (03) : 731 - 734
  • [10] Görich J, 1999, RADIOLOGY, V213, P767