Intravascular carbon dioxide monitoring using micro-flow colorimetry

被引:7
作者
Cooney, CG [1 ]
Towe, BC [1 ]
机构
[1] ARIZONA STATE UNIV,DEPT CHEM BIO & MAT ENGN,BIOENGN PROGRAM,TEMPE,AZ 85287
关键词
carbon dioxide; colorimetry; microdialysis; micro-flow; optical detection; withdrawal-reinfusion;
D O I
10.1016/0956-5663(96)89085-3
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
An intravascular carbon dioxide sensor is investigated which employs continuous perfusion of micro-quantities of reagent through silicone membrane tubing in contact with blood. Blood is sampled from a vessel by periodic withdrawal-reinfusion through a catheter and passes by the sensor membrane tubing integrated into the catheter system. Blood CO2 equilibrates across the silicone membrane causing a color change in the reagent micro-dow stream that is detected by an optical cell external to the vessel. In vivo trials on pigs demonstrate a stable sensor response, a fast response time, and high signal-to-noise ratios. The sensor also exhibits an immunity to temperature changes, reduced intravascular blood flow, photobleaching, and leaching. It has a 2 min response time, a +/-2 mmHg resolution, and minimal drift over a 12 h duration. Using a pig model, measured values compared with true values indicate a 0.998 correlation coefficient, a 1.3 mmHg precision, and a 1.7 mmHg bias. (C) 1996 Elsevier Science Limited
引用
收藏
页码:11 / 17
页数:7
相关论文
共 17 条
[1]  
BARKER SJ, 1991, ANESTH ANALG, V73, P43
[2]   RATE OF RISE OF MYOCARDIAL PCO2 DURING EARLY MYOCARDIAL ISCHEMIA IN THE DOG [J].
CASE, RB ;
FELIX, A ;
CASTELLANA, FS .
CIRCULATION RESEARCH, 1979, 45 (03) :324-330
[3]   OPTICAL FLUORESCENCE AND ITS APPLICATION TO AN INTRAVASCULAR BLOOD-GAS MONITORING-SYSTEM [J].
GEHRICH, JL ;
LUBBERS, DW ;
OPITZ, N ;
HANSMANN, DR ;
MILLER, WW ;
TUSA, JK ;
YAFUSO, M .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1986, 33 (02) :117-132
[4]   SILICONE RUBBER AS A SELECTIVE BARRIER [J].
KAMMERMEYER, K .
INDUSTRIAL AND ENGINEERING CHEMISTRY, 1957, 49 (10) :1685-1686
[5]   MULTISITE EVALUATION OF A CONTINUOUS INTRAARTERIAL BLOOD-GAS MONITORING-SYSTEM [J].
LARSON, CP ;
VENDER, J ;
SEIVER, A .
ANESTHESIOLOGY, 1994, 81 (03) :543-552
[6]   PROGRESS IN THE DEVELOPMENT OF A FLUORESCENT INTRAVASCULAR BLOOD-GAS SYSTEM IN MAN [J].
MAHUTTE, CK ;
SASSOON, CSH ;
MURO, JR ;
HANSMANN, DR ;
MAXWELL, TP ;
MILLER, WW ;
YAFUSO, M .
JOURNAL OF CLINICAL MONITORING, 1990, 6 (02) :147-157
[7]   MYOCARDIAL HYPERCARBIC ACIDOSIS REDUCES CARDIAC RESUSCITABILITY [J].
MALDONADO, FA ;
WEIL, MH ;
TANG, WC ;
BISERA, J ;
GAZMURI, RJ ;
JOHNSON, B ;
DALESSIO, A .
ANESTHESIOLOGY, 1993, 78 (02) :343-352
[8]   USE OF THE MICRODIALYSIS TECHNIQUE IN THE MONITORING OF SUBCUTANEOUS TISSUE GLUCOSE-CONCENTRATION [J].
MEYERHOFF, C ;
BISCHOF, F ;
MENNEL, FJ ;
STERNBERG, F ;
PFEIFFER, EF .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 1993, 16 (05) :268-275
[9]  
MILLER WW, 1987, CLIN CHEM, V33, P1538
[10]   FIBEROPTIC SENSORS FOR PH AND CARBON-DIOXIDE USING A SELF-REFERENCING DYE [J].
PARKER, JW ;
LAKSIN, O ;
YU, C ;
LAU, ML ;
KLIMA, S ;
FISHER, R ;
SCOTT, I ;
ATWATER, BW .
ANALYTICAL CHEMISTRY, 1993, 65 (17) :2329-2334