Comparison of CID spectra of singly charged polypeptide antibiotic precursor ions obtained by positive-ion vacuum MALDI IT/RTOF and TOF/RTOF, AP-MALDI-IT and ESI-IT mass spectrometry

被引:38
作者
Pittenauer, E
Zehl, M
Belgacem, O
Raptakis, E
Mistrik, R
Allmaier, G
机构
[1] Vienna Univ Technol, Inst Chem Technol & Analyt, A-1060 Vienna, Austria
[2] Shimadzu Biotech Kratos Analyt, Manchester, Lancs, England
[3] HighChem, Bratislava, Slovakia
来源
JOURNAL OF MASS SPECTROMETRY | 2006年 / 41卷 / 04期
关键词
low-energy CID; high-energy CID; vacuum MALDI; AP-MALDI; ESI; tandem and multistage MS; antibiotics;
D O I
10.1002/jms.1032
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Various classes of polypeptide antibiotics, including blocked linear peptides (gramicidin D), side-chain-cyclized peptides (bacitracin, viomycin, capreomycin), side-chain-cyclized depsipeptides (virginiamycin S), real cyclic peptides (tyrocidin, gramcidin S) and side-chain-cyclized lipopeptides (polymyxin B and E, amfomycin), were investigated by low-energy collision induced dissociation (LE-CID) as well as high-energy CID (HE-CID). Ion trap (IT) based instruments with different desorption/ionization techniques such as electrospray ionization (ESI), atmospheric pressure matrix-assisted laser desorption/ionization (AP-MALDI) and vacuum MALDI (vMALDI) as well as a vMALDI-time-of-flight (TOF)/curved field-reflectron instrument fitted with a gas collision cell were used. For optimum comparability of data from different IT instruments, the CID conditions were standardized and only singly charged precursor ions were considered. Additionally, HE-CID data obtained from the TOF-based instrument were acquired and compared with LE-CID data from IT's. Major differences between trap-based and TOF-based CID data are that the latter data set lacks abundant additional loss of small neutrals (e.g. ammonia, water) but contains product ions down to the immonium-ion-type region, thereby allowing the detection of even single amino-acid (even unusual amino acids) substitutions. For several polypeptide antibiotics, mass spectrometric as well as tandem mass spectrometric data are shown and discussed for the first time, and some yet undescribed minor components are also reported. De novo sequencing of unusually linked minor components of (e.g. cyclic) polypeptides is practically impossible without knowledge of the exact structure and fragmentation behavior of the major components. Finally, the described standardized CID condition constitutes a basic prerequisite for creating a searchable, annotated MSn-database of bioactive compounds. The applied desorption/ionization techniques showed no significant influence on the type of product ions (neglecting relative abundances of product ions formed) observed, and therefore the type of analyzer connected with the CID process mainly determines the type of fragment ions. Copyright (c) 2006 John Wiley & Sons, Ltd.
引用
收藏
页码:421 / 447
页数:27
相关论文
共 44 条
[1]   AN INVESTIGATION OF THE TYROTHRICIN COMPLEX BY TANDEM MASS-SPECTROMETRY [J].
BARBER, M ;
BELL, DJ ;
MORRIS, MR ;
TETLER, LW ;
MONAGHAN, JJ ;
MORDEN, WE ;
BYCROFT, BW ;
GREEN, BN .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1992, 122 :143-151
[2]   CONTRIBUTIONS OF MASS-SPECTROMETRY TO PEPTIDE AND PROTEIN-STRUCTURE [J].
BIEMANN, K .
BIOMEDICAL AND ENVIRONMENTAL MASS SPECTROMETRY, 1988, 16 (1-12) :99-111
[3]   STRUCTURE OF PEPTIDE ANTIBIOTIC AMPHOMYCIN [J].
BODANSZKY, M ;
SIGLER, GF ;
BODANSZKY, A .
JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1973, 95 (07) :2352-2357
[4]  
BOWDLER AR, 2005, P 53 ASMS C MASS SPE
[5]   Antimicrobial growth promoters used in animal feed: Effects of less well known antibiotics on gram-positive bacteria [J].
Butaye, P ;
Devriese, LA ;
Haesebrouck, F .
CLINICAL MICROBIOLOGY REVIEWS, 2003, 16 (02) :175-+
[6]   Liquid chromatography-mass spectrometry study towards the pH and temperature-induced N-acyl migration in polymyxin B [J].
de Visser, PC ;
Govaerts, C ;
van Hooft, PAV ;
Overkleeft, HS ;
Van Schepdael, A ;
Hoogmartens, J .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1058 (1-2) :183-189
[7]   Hyphenation of liquid chromatography to ion trap mass spectrometry to identify minor components in polypeptide antibiotics [J].
Govaerts, C ;
Adams, E ;
Van Schepdael, A ;
Hoogmartens, J .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2003, 377 (05) :909-921
[8]   Sequencing of bacitracin A and related minor components by liquid chromatography/electrospray ionization ion trap tandem mass spectrometry [J].
Govaerts, C ;
Li, CL ;
Orwa, J ;
Van Schepdael, A ;
Adams, E ;
Roets, E ;
Hoogmartens, J .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2003, 17 (12) :1366-1379
[9]   Characterization of polypeptide antibiotics of the polymyxin series by liquid chromatography electrospray ionization ion trap tandem mass spectrometry [J].
Govaerts, C ;
Orwa, J ;
Van Schepdael, A ;
Roets, E ;
Hoogmartens, J .
JOURNAL OF PEPTIDE SCIENCE, 2002, 8 (02) :45-55
[10]   Liquid chromatography-ion trap tandem mass spectrometry for the characterization of polypeptide antibiotics of the colistin series in commercial samples [J].
Govaerts, C ;
Orwa, J ;
Van Schepdael, A ;
Roets, E ;
Hoogmartens, J .
JOURNAL OF CHROMATOGRAPHY A, 2002, 976 (1-2) :65-78