Radiometry using synchrotron radiation at PTB

被引:13
作者
Richter, M [1 ]
Ulm, G [1 ]
机构
[1] Phys Tech Bundesanstalt, D-10587 Berlin, Germany
关键词
synchrotron radiation; radiometry; detector calibration; source calibration; reflectometry;
D O I
10.1016/S0368-2048(98)00383-1
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
The facilities for radiometry using synchrotron radiation at the Physikalisch-Technische Bundesanstalt are presented and the methods for absolute calibration of radiation sources and detectors are described. Most of the measurements are based on the use of two different types of primary standards, storage rings as primary radiation source standards and cryogenic electrical substitution radiometers as primary detector standards. The facilities allow us to offer radiometric calibrations in the spectral range from the UV to x-rays with relative uncertainties down to 0.4%. (C) 1999 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:1013 / 1018
页数:6
相关论文
共 30 条
[1]   DETERMINATION OF PHOTON-EMISSION PROBABILITIES OF RADIONUCLIDES USING A SI(LI) DETECTOR CALIBRATED BY THE PRIMARY STANDARD SOURCE, BESSY [J].
ARNOLD, D ;
ULM, G .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 339 (1-2) :43-48
[2]   High-accuracy calibration of the HXDS flow proportional counter for AXAF at the PTB laboratory at BESSY [J].
Auerhammer, JM ;
Brandt, G ;
Scholze, F ;
Thomagel, R ;
Ulm, G ;
Wargelin, BJ ;
McDermott, WC ;
Norton, TJ ;
Evans, IN ;
Kellogg, EM .
X-RAY OPTICS, INSTRUMENTS, AND MISSIONS, 1998, 3444 :19-29
[3]   X-ray CCD calibration for the AXAF CCD imaging spectrometer [J].
Bautz, M ;
Pivovaroff, M ;
Baganoff, F ;
Isobe, T ;
Jones, S ;
Kissel, S ;
LaMarr, B ;
Manning, H ;
Prigozhin, G ;
Ricker, G ;
Nousek, J ;
Grant, C ;
Nishikida, K ;
Scholze, F ;
Thornagel, R ;
Ulm, G .
X-RAY OPTICS, INSTRUMENTS, AND MISSIONS, 1998, 3444 :210-224
[4]   The performance of transmission filters for EUV & soft X-ray astronomy [J].
Bavdaz, M ;
Peacock, A ;
denHartog, R ;
Poelaert, A ;
Underwood, P ;
Viitanen, VP ;
Fuchs, D ;
Bulicke, P ;
Kraft, S ;
Scholze, F ;
Ulm, G ;
Wright, AC .
EUV, X-RAY, AND GAMMA-RAY INSTRUMENTATION FOR ASTRONOMY VII, 1996, 2808 :301-312
[6]   A BEAM LINE FOR RADIANT POWER MEASUREMENTS OF VACUUM ULTRAVIOLET AND ULTRAVIOLET SOURCES IN THE WAVELENGTH RANGE 40-400-NM [J].
HOLLANDT, J ;
JANS, W ;
KUHNE, M ;
LINDENLAUF, F ;
WENDE, B .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (01) :1278-1281
[7]   HOLLOW-CATHODE TRANSFER STANDARDS FOR THE RADIOMETRIC CALIBRATION OF VUV TELESCOPES OF THE SOLAR AND HELIOSPHERIC OBSERVATORY (SOHO) [J].
HOLLANDT, J ;
HUBER, MCE ;
KUHNE, M .
METROLOGIA, 1993, 30 (04) :381-388
[8]   Measurement of the electron energy and energy spread at the electron storage ring BESSY I [J].
Klein, R ;
Mayer, T ;
Kuske, P ;
Thornagel, R ;
Ulm, G .
JOURNAL OF SYNCHROTRON RADIATION, 1998, 5 :392-394
[9]   The PTB electromagnetic undulator for BESSY II [J].
Klein, R ;
Bahrdt, J ;
Herzog, D ;
Ulm, G .
JOURNAL OF SYNCHROTRON RADIATION, 1998, 5 :451-452
[10]   Beam diagnostics at the BESSY I electron storage ring with Compton backscattered laser photons: Measurement of the electron energy and related quantities [J].
Klein, R ;
Mayer, T ;
Kuske, P ;
Thornagel, R ;
Ulm, G .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 384 (2-3) :293-298