Risk of catheter-related emboli in patients with atherosclerotic debris in the thoracic aorta

被引:108
作者
Karalis, DG
Quinn, V
Victor, MF
Ross, JJ
Polansky, M
Spratt, KA
Chandrasekaran, K
机构
[1] Division of Cardiovascular Diseases, Hahnemann University Hospital, Philadelphia
[2] Hahnemann University Hospital, Mail Stop 313, Philadelphia, PA 19102, Broad and Vine
关键词
D O I
10.1016/S0002-8703(96)90090-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The aim of this study was to evaluate the risk of performing cardiac catheterization or intraaortic balloon pump placement in patients with transesophageal echocardiographically detected atherosclerotic aortic debris. cardiac catheterization was performed in 70 patients with atherosclerotic aortic debris (in 11 via the brachial approach and in 59 via the femoral approach) and in 71 control patients. An embolic event occurred in 10 (17%) of 59 patients with atherosclerotic aortic debris after femoral catheterization compared to 2 (3%) of 71 control patients without atherosclerotic aortic debris (p = 0.01). None of the 11 patients with atherosclerotic aortic debris who underwent brachial catheterization had an embolic event. An intraaortic balloon pump was placed in 10 patients with atherosclerotic aortic debris and in 12 control patients. An embolic event related to placement of the intraaortic balloon pump occurred in 5 (50%) of 10 patients with atherosclerotic aortic debris; no control patient had an embolic event (p = 0.02). Patients with mobile atherosclerotic aortic debris were at the highest risk for catheter-related embolism. The strongest clinical predictors of atherosclerotic aortic debris were advanced age and peripheral vascular disease.Transesophageal echocardiographic recognition of atherosclerotic aortic debris identifies patients at high risk of stroke or peripheral embolism after cardiac catheterization or intraaortic balloon pump placement. If the aortic debris is mobile, the risk is particularly high. When atherosclerotic aortic debris is detected, especially if the debris is mobile, substituting brachial for femoral catheterization and avoiding placement of an intraaortic balloon pump may reduce the risk of embolism.
引用
收藏
页码:1149 / 1155
页数:7
相关论文
共 20 条
[1]   ATHEROSCLEROTIC DISEASE OF THE AORTIC-ARCH AND THE RISK OF ISCHEMIC STROKE [J].
AMARENCO, P ;
COHEN, A ;
TZOURIO, C ;
BERTRAND, B ;
HOMMEL, M ;
BESSON, G ;
CHAUVEL, C ;
TOUBOUL, PJ ;
BOUSSER, MG .
NEW ENGLAND JOURNAL OF MEDICINE, 1994, 331 (22) :1474-1479
[2]  
BLAUTH CI, 1992, J THORAC CARDIOV SUR, V103, P1104
[3]   CHOLESTEROL EMBOLI AFTER CARDIAC-CATHETERIZATION - 8 CASES AND A REVIEW OF THE LITERATURE [J].
COLT, HG ;
BEGG, RJ ;
SAPORITO, JJ ;
COOPER, WM ;
SHAPIRO, AP .
MEDICINE, 1988, 67 (06) :389-400
[4]  
DROST H, 1984, BRIT HEART J, V52, P3398
[5]   TRANSESOPHAGEAL ECHOCARDIOGRAPHICALLY DETECTED ATHEROSCLEROTIC AORTIC PLAQUE IS A MARKER FOR CORONARY-ARTERY DISEASE [J].
FAZIO, GP ;
REDBERG, RF ;
WINSLOW, T ;
SCHILLER, NB .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1993, 21 (01) :144-150
[6]   CORONARY ARTERIOGRAPHY 1984-1987 - A REPORT OF THE REGISTRY OF THE SOCIETY FOR CARDIAC ANGIOGRAPHY AND INTERVENTIONS .1. RESULTS AND COMPLICATIONS [J].
JOHNSON, LW ;
LOZNER, EC ;
JOHNSON, S ;
KRONE, R ;
PICHARD, AD ;
VETROVEC, GW ;
NOTO, TJ .
CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1989, 17 (01) :5-10
[7]   RECOGNITION AND EMBOLIC POTENTIAL OF INTRAAORTIC ATHEROSCLEROTIC DEBRIS [J].
KARALIS, DG ;
CHANDRASEKARAN, K ;
VICTOR, MF ;
ROSS, JJ ;
MINTZ, GS .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1991, 17 (01) :73-78
[8]   SPONTANEOUS ARTERIAL EMBOLIZATION AFTER THROMBOLYTIC THERAPY FOR ACUTE MYOCARDIAL-INFARCTION - THE ROLE OF TRANSESOPHAGEAL ECHOCARDIOGRAPHY [J].
KARALIS, DG ;
KAULBACK, KW ;
ROSS, JJ ;
URICCHIO, FJ ;
CHANDRASEKARAN, K .
CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1994, 31 (03) :199-201
[9]   PROTRUDING AORTIC ATHEROMAS PREDICT STROKE IN ELDERLY PATIENTS UNDERGOING CARDIOPULMONARY BYPASS - EXPERIENCE WITH INTRAOPERATIVE TRANSESOPHAGEAL ECHOCARDIOGRAPHY [J].
KATZ, ES ;
TUNICK, PA ;
RUSINEK, H ;
RIBAKOVE, G ;
SPENCER, FC ;
KRONZON, I .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 20 (01) :70-77
[10]   OBSERVATIONS OF CORONARY FLOW AUGMENTATION AND BALLOON FUNCTION DURING INTRAAORTIC BALLOON COUNTERPULSATION USING TRANSESOPHAGEAL ECHOCARDIOGRAPHY [J].
KATZ, ES ;
TUNICK, PA ;
KRONZON, I .
AMERICAN JOURNAL OF CARDIOLOGY, 1992, 69 (19) :1635-1639