Optimization of Gas Turbine Cogeneration System for Various Heat Exchanger Configurations

被引:7
作者
Costea, M. [1 ]
Feidt, M. [2 ]
Alexandru, G. [1 ]
Descieux, D. [2 ]
机构
[1] Univ Politehn Bucuresti, Dept Engn Thermodynam, Bucharest 060042, Romania
[2] Univ Henri Poincare Nancy, ENSEM LEMTA, F-54516 Vandoeuvre Les Nancy, France
来源
OIL & GAS SCIENCE AND TECHNOLOGY-REVUE D IFP ENERGIES NOUVELLES | 2012年 / 67卷 / 03期
关键词
POWER OPTIMIZATION; BRAYTON CYCLE; PERFORMANCE; ENERGY; PLANTS; MICRO;
D O I
10.2516/ogst/2011140
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Optimization of Gas Turbine Cogeneration System for Various Heat Exchanger Configurations The present paper investigates and compares the performance of three configurations of Gas Turbine systems allowing cogeneration of heat and electricity, on the basis of an irreversible regenerative Brayton-Joule cycle. The proposed model is developed for two different cycle constraints, namely, an imposed heat transfer rate released by the fuel combustion, or an imposed maximum cycle temperature. The model also includes the irreversibility due to the friction in the compressor and turbine, and due to the heat losses in the combustion chamber and heat exchangers. Energy efficiency for the system without and with cogeneration, and the exergetic efficiency are used in order to emphasize the cogeneration advantages, but also to help the designer to choose the best configuration of the Gas Turbine system that suits to his needs. Experimental data from a real operating microturbine were used to validate the model. The power output and the energy and exergetic efficiencies are optimized with respect to a set of operating parameters. The optimum values of the Gas Turbine engine parameters corresponding to maximum power output and respectively to maximum thermodynamic efficiency are discussed. The results show same optimal values of the compression ratio corresponding to almost all maximum performances for an imposed heat transfer rate released by the fuel combustion, excepting the maximum exergetic efficiency that requires higher optimal values of the compression ratio than the maximum exergy rate one. A performance comparison of the three configurations is done and future perspectives of the work are proposed.
引用
收藏
页码:517 / 535
页数:19
相关论文
共 36 条
[1]   Exergoenvironmental analysis and optimization of a cogeneration plant system using Multimodal Genetic Algorithm (MGA) [J].
Ahmadi, Pouria ;
Dincer, Ibrahim .
ENERGY, 2010, 35 (12) :5161-5172
[2]   Effects of thermodynamic and mechanical irreversibilities on gas turbine performance enhancement by intake air cooling [J].
Department of Mechanical Engineering, College of Engineering, University of Bahrain, Bahrain .
Int. J. Exergy, 2009, 2 (166-180) :166-180
[3]   Co-production of synthesis gas and power by integration of Partial Oxidation reactor, gas turbine and air separation unit [J].
Albrecht, B. A. ;
Kok, J. B. W. ;
van der Meer, Th. H. .
INTERNATIONAL JOURNAL OF EXERGY, 2007, 4 (04) :357-370
[4]  
Alexandru G., 2007, ANAL MODELING GAS TU
[5]   Energetic and exergetic performance evaluation of a combined heat and power system with the micro gas turbine (MGTCHP) [J].
Balli, Ozgur ;
Aras, Haydar .
INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2007, 31 (14) :1425-1440
[6]   Investment criteria for the selection of cogeneration plants -: a state of the art review [J].
Biezma, MV ;
San Cristóbal, JR .
APPLIED THERMAL ENGINEERING, 2006, 26 (5-6) :583-588
[7]   Second law analysis of a waste heat recovery based power generation system [J].
Butcher, C. J. ;
Reddy, B. V. .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2007, 50 (11-12) :2355-2363
[8]  
Capata R, 2006, INT J THERMODYN, V9, P81
[9]   Experimentation on a cogenerative system based on a microturbine [J].
Colombo, Luigi P. M. ;
Armanasco, Fabio ;
Perego, Omar .
APPLIED THERMAL ENGINEERING, 2007, 27 (04) :705-711
[10]  
Descieux D., 2005, 9 GAT CNRS