Early Healing of Nanothickness Bioceramic Coatings on Dental Implants. An Experimental Study in Dogs

被引:78
作者
Coelho, Paulo G. [1 ]
Cardaropoli, Giuseppe [2 ]
Suzuki, Marcelo [3 ]
Lemons, Jack E. [4 ]
机构
[1] NYU, Coll Dent, Dept Biomat & Biomimet, New York, NY 10010 USA
[2] NYU, Coll Dent, Dept Periodontol & Implant Dent, New York, NY 10010 USA
[3] Tufts Univ, Sch Dent Med, Dept Prosthodont & Operat Dent, Boston, MA 02111 USA
[4] Univ Alabama Birmingham, Dept Prosthodont & Biomat, Birmingham, AL 35294 USA
关键词
implant design; in vivo; surface modification; coating(s); biomechanics; PLASMA-SPRAYED HYDROXYAPATITE; CALCIUM-PHOSPHATE COATINGS; ENDOSSEOUS IMPLANTS; TITANIUM IMPLANTS; BONE; SURFACES;
D O I
10.1002/jbm.b.31090
中图分类号
R318 [生物医学工程];
学科分类号
100103 [病原生物学];
摘要
Thick bioceramic coatings like plasma sprayed hydroxyapatite have been shown to increase the overall tissue response and biomechanical fixation of dental implants. However, the presence and potential fracture of a bone-coating-metallic substrate interface at long times after implantation led these implants to fall from favor in clinical practice. The purpose of this study was to evaluate the biomechanical fixation and biological response of Ca- and P-based, 20-50 nm thickness bioceramic deposition on a previously alumina-blasted/acid-etched Ti-6Al-4V implant surface in a dog model. Cylindrical alumina-blasted/acid-etched (AB/AE) (Control, n = 16), and Nanothickness bioceramic coated AB/AE(Nano, n = 16) implant surfaces were surgically placed in dogs proximal tibia and remained for 2 and 4 weeks in vivo. Following euthanization, the implants-in-bone were mounted in epoxy and pullout at a 0.5 mm/min rate. Following mechanical testing, the specimens were decalcified and processed (Hematoxylin and Eosin) for standard transmitted light microscopy evaluation. Percent bone-to-implant contact (BIC) to the pulled out implant surface was determined through computer software. Statistical analyses were performed by one-way ANOVA at 95% level of significance and Tukey's post-hoc multiple comparisons. No significant differences in pullout force were observed (p > 0.88): 2W Control (212.08 +/- 42.96 N), 2W Nano (224.35 +/- 42.97 N), 4W Control (207.07 +/- 42.97 N), and 4W Nano (190.15 +/- 45.94 N). No significant differences in %BIC were observed (p > 0.94): 2W Control (72.66 +/- 8.51), 2W Nano (69.44 +/- 8.51), 4W Control (70.44 +/- 8.51), and 4W Nano (69.11 +/- 9.09). It is shown that 20-50 nm thickness bioceramic depositions onto previously alumina-blasted/acid-etched substrates did not improve the biomechanical fixation and the BIC at early implantation times, and studies concerning shorter and longer implantation times are recommended for confirmation or before a conclusion can be made. (c) 2008 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 88B: 387-393, 2009
引用
收藏
页码:387 / 393
页数:7
相关论文
共 30 条
[1]
Peri-implant hard and soft tissue integration to dental implants made of titanium and gold [J].
Abrahamsson, Ingemar ;
Cardaropoli, Giuseppe .
CLINICAL ORAL IMPLANTS RESEARCH, 2007, 18 (03) :269-274
[2]
OSSEOINTEGRATED TITANIUM IMPLANTS - REQUIREMENTS FOR ENSURING A LONG-LASTING, DIRECT BONE-TO-IMPLANT ANCHORAGE IN MAN [J].
ALBREKTSSON, T ;
BRANEMARK, PI ;
HANSSON, HA ;
LINDSTROM, J .
ACTA ORTHOPAEDICA SCANDINAVICA, 1981, 52 (02) :155-170
[3]
Albrektsson T, 2004, INT J PROSTHODONT, V17, P544
[4]
Albrektsson T, 2004, INT J PROSTHODONT, V17, P536
[5]
Bone healing at implants with a fluoride-modified surface: an experimental study in dogs [J].
Berglundh, T. ;
Abrahamsson, I. ;
Albouy, J. -P. ;
Lindhe, J. .
CLINICAL ORAL IMPLANTS RESEARCH, 2007, 18 (02) :147-152
[6]
Bone reactions to longstanding functional load at implants: an experimental study in dogs [J].
Berglundh, T ;
Abrahamsson, I ;
Lindhe, J .
JOURNAL OF CLINICAL PERIODONTOLOGY, 2005, 32 (09) :925-932
[7]
De novo alveolar bone formation adjacent to endosseous implants -: A model study in the dog [J].
Berglundh, T ;
Abrahamsson, I ;
Lang, NP ;
Lindhe, J .
CLINICAL ORAL IMPLANTS RESEARCH, 2003, 14 (03) :251-262
[8]
Highly crystalline Mp-1™ hydroxylapatite coating Part II:: In vivo performance on endosseous root implants in dogs [J].
Burgess, AV ;
Story, BJ ;
Wagner, WR ;
Trisi, P ;
Pikos, MA ;
Guttenberg, SA .
CLINICAL ORAL IMPLANTS RESEARCH, 1999, 10 (04) :257-266
[9]
Enhanced bone apposition to a chemically modified SLA titanium surface [J].
Buser, D ;
Broggini, N ;
Wieland, M ;
Schenk, RK ;
Denzer, AJ ;
Cochran, DL ;
Hoffmann, B ;
Lussi, A ;
Steinemann, SG .
JOURNAL OF DENTAL RESEARCH, 2004, 83 (07) :529-533
[10]
Harder and stiffer bone Osseointegrated to roughened titanium [J].
Butz, F. ;
Aita, H. ;
Wang, C. J. ;
Ogawa, T. .
JOURNAL OF DENTAL RESEARCH, 2006, 85 (06) :560-565