Effect of vessel size on the flow efficiency of the total cavopulmonary connection: In vitro studies

被引:14
作者
DeGroff, CG
Carlton, JD
Weinberg, CE
Ellison, MC
Shandas, R
Valdes-Cruz, L
机构
[1] Univ Colorado, Hlth Sci Ctr, Childrens Hosp, Denver, CO 80218 USA
[2] Univ Colorado, Dept Mech Engn, Boulder, CO 80303 USA
关键词
D O I
10.1007/s00246-001-0042-y
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The total cavopulmonary connection (TCPC) creates a passive system of blood flow into the pulmonary circulation. We hypothesize that the efficiency differences found in models with superior vena cava-inferior vena cava (SVC-IVC) offsets is dependent on vessel size, with flow efficiency improving with larger size vessels. Two sets of in vitro TCPC models (TCPC-3 and TCPC-15) were constructed corresponding to average vessel diameters of 3- and 15-year-old patients. The model with full SVC-IVC offset was the most efficient in TCPC-3 models. There was no significant difference between geometric arrangements in TCPC-15 models; however, the average efficiencies were significantly higher. Among the models representing vessel sizes of the younger age group, the model with the full-diameter SVC-IVC offset was the most efficient. The models representing vessel sizes of the older age group showed marked improvement in efficiencies throughout without obvious differences between various geometric arrangements. This suggests that geometric considerations in TCPC surgical techniques may be of lower than expected significance over the life span of a patient. More important, after balancing the effects of improved flow efficiency with larger vessels against the effects of chronic volume overload, the trend of performing the Fontan surgery on increasingly younger patients may need to be reconsidered after further studies.
引用
收藏
页码:171 / 177
页数:7
相关论文
共 27 条
[1]   Pressure loss from flow energy dissipation: Relevance to Fontan-type modifications [J].
Ascuitto, RJ ;
Kydon, DW ;
Ross-Ascuitto, NT .
PEDIATRIC CARDIOLOGY, 2001, 22 (02) :110-115
[2]   In vivo evaluation of Fontan pathway flow dynamics by multidimensional phase-velocity magnetic resonance imaging [J].
Be'eri, E ;
Maier, SE ;
Landzberg, MJ ;
Chung, T ;
Geva, T .
CIRCULATION, 1998, 98 (25) :2873-2882
[3]  
Carlton J, 2000, CIRCULATION, V102, P744
[4]   The Fontan circulation: What have we learned? What to expect? [J].
de Leval, MR .
PEDIATRIC CARDIOLOGY, 1998, 19 (04) :316-320
[5]   Use of computational fluid dynamics in the design of surgical procedures: Application to the study of competitive flows in cavopulmonary connections [J].
deLeval, MR ;
Dubini, G ;
Migliavacca, F ;
Jalali, H ;
Camporini, G ;
Redington, A ;
Pietrabissa, R .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1996, 111 (03) :502-510
[6]  
DELEVAL MR, 1988, J THORAC CARDIOV SUR, V96, P682
[7]   5-YEAR TO 15-YEAR FOLLOW-UP AFTER FONTAN OPERATION [J].
DRISCOLL, DJ ;
OFFORD, KP ;
FELDT, RH ;
SCHAFF, HV ;
PUGA, FJ ;
DANIELSON, GK .
CIRCULATION, 1992, 85 (02) :469-496
[8]   A numerical fluid mechanical study of repaired congenital heart defects. Application to the total cavopulmonary connection [J].
Dubini, G ;
deLeval, MR ;
Pietrabissa, R ;
Montevecchi, FM ;
Fumero, R .
JOURNAL OF BIOMECHANICS, 1996, 29 (01) :111-121
[9]   The mature of flow in the systemic venous pathway measured by magnetic resonance blood tagging in patients having the Fontan operation [J].
Fogel, MA ;
Weinberg, PM ;
Hoydu, A ;
Hubbard, A ;
Rychik, J ;
Jacobs, M ;
Fellows, KE ;
Haselgrove, J .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1997, 114 (06) :1032-1041
[10]   SURGICAL REPAIR OF TRICUSPID ATRESIA [J].
FONTAN, F ;
BAUDET, E .
THORAX, 1971, 26 (03) :240-+