Impact of sedation and organ failure on continuous heart and respiratory rate variability monitoring in critically ill patients: A pilot study

被引:29
作者
Bradley, Beverly D. [1 ]
Green, Geoffrey [1 ]
Ramsay, Tim [1 ]
Seely, Andrew J. E. [1 ,2 ,3 ]
机构
[1] Ottawa Hosp, Res Inst, Ottawa, ON, Canada
[2] Univ Ottawa, Div Thorac Surg, Ottawa, ON, Canada
[3] Univ Ottawa, Dept Crit Care Med, Ottawa, ON, Canada
基金
加拿大健康研究院;
关键词
continuous monitoring; critical illness; heart rate variability; multiple organ dysfunction syndrome; respiratory rate variability; sedation; DYSFUNCTION SYNDROME; APPROXIMATE ENTROPY; HOSPITAL MORTALITY; MIDAZOLAM SEDATION; DAILY INTERRUPTION; BREATHING PATTERN; SPECTRAL-ANALYSIS; PROPOFOL; PREDICTOR; INFUSIONS;
D O I
10.1097/CCM.0b013e31826a47de
中图分类号
R4 [临床医学];
学科分类号
100218 [急诊医学];
摘要
Objective: Our aim is to better characterize the impact of sedation and its interruption on continuously monitored heart rate variability and respiratory rate variability in critically ill patients. We aim to explore whether sedation reduces heart rate variability and respiratory rate variability in critically ill patients and whether the extent of reduction depends on degree of organ dysfunction. Design: Prospective observational pilot study. Setting: Intensive care unit in tertiary care teaching hospital. Patients: Thirty-three critically ill adult patients experiencing respiratory and/or cardiac failure. Interventions: Electrocardiogram and end-tidal capnography waveform capture were initiated from admission or intubation, res-pectively, and continued to intensive care unit discharge or a maximum of 14 d. Measurements and Main Results: All patient days with a sedation interruption (defined as cessation of a continuous infusion of sedation agent) were identified. Mean heart rate variability and respiratory rate variability were computed over two periods: 4 hrs directly prior to the sedation interruption, and the duration of sedation interruption (median: 1 hr 45 mins, interquartile range: 4 hrs 15 mins or max 4 hrs). Severity of organ dysfunction was assessed through multiple organ dysfunction syndrome scores, and sedative agents were recorded for each sedation interruption. Multiple organ dysfunction syndrome levels were defined as low (0-2), medium (3-4), and high (> 4). Variability before and during sedation interruption was compared and analyzed across multiple organ dysfunction syndrome levels and sedative types. Our results suggest that both heart rate variability and respiratory rate variability increased during sedation interruption (p < 0.05 for coefficient of variation). Patients with low and medium multiple organ dysfunction syndrome experienced greater increase in heart rate variability during sedation interruption (p < 0.05 for coefficient of variation), compared to patients with high multiple organ dysfunction syndrome, who failed to mount a significant increase in heart rate variability when sedation was stopped. Similarly, sedation interruption led to increased respiratory rate variability for low multiple organ dysfunction syndrome patients (p < 0.05 for (SD)), but in contrast, a further deterioration in respiratory rate variability occurred in the high multiple organ dysfunction syndrome patients. All trends persisted when controlling for sedative agents. Conclusions: Interruption of sedation allows for uncovering a greater restoration of heart rate variability and respiratory rate variability in patients with low organ failure. The further reduction in respiratory variability during the elimination of sedation in patients with high multiple organ dysfunction syndrome suggests a differential response and benefit from sedation interruption, and merits further investigation. As reduced variability correlates with severity of illness, and need for sedation depends on organ failure, variability monitoring may offer a dynamic measure of a variable response to the benefit, timing, and duration of sedation interruption. (Crit Care Med 2013;41:433-444)
引用
收藏
页码:433 / 444
页数:12
相关论文
共 45 条
[1]
Continuous Multi-Parameter Heart Rate Variability Analysis Heralds Onset of Sepsis in Adults [J].
Ahmad, Saif ;
Ramsay, Tim ;
Huebsch, Lothar ;
Flanagan, Sarah ;
McDiarmid, Sheryl ;
Batkin, Izmail ;
McIntyre, Lauralyn ;
Sundaresan, Sudhir R. ;
Maziak, Donna E. ;
Shamji, Farid M. ;
Hebert, Paul ;
Fergusson, Dean ;
Tinmouth, Alan ;
Seely, Andrew J. E. .
PLOS ONE, 2009, 4 (08)
[2]
POWER SPECTRUM ANALYSIS OF HEART-RATE FLUCTUATION - A QUANTITATIVE PROBE OF BEAT-TO-BEAT CARDIOVASCULAR CONTROL [J].
AKSELROD, S ;
GORDON, D ;
UBEL, FA ;
SHANNON, DC ;
BARGER, AC ;
COHEN, RJ .
SCIENCE, 1981, 213 (4504) :220-222
[3]
Inappropriate sympathetic activation at onset of septic shock - A spectral analysis approach [J].
Annane, D ;
Trabold, F ;
Sharshar, T ;
Jarrin, I ;
Blanc, AS ;
Raphael, JC ;
Gajdos, P .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1999, 160 (02) :458-465
[4]
Use of sedatives and neuromuscular blockers in a cohort of patients receiving mechanical ventilation [J].
Arroliga, A ;
Frutos-Vivar, F ;
Hall, J ;
Esteban, A ;
Apezteguía, C ;
Soto, L ;
Anzueto, A .
CHEST, 2005, 128 (02) :496-506
[5]
Heart rate variability in emergency department patients with sepsis [J].
Barnaby, D ;
Ferrick, K ;
Kaplan, DT ;
Shah, S ;
Bijur, P ;
Gallagher, EJ .
ACADEMIC EMERGENCY MEDICINE, 2002, 9 (07) :661-670
[6]
Breathing pattern variability: a weaning predictor in postoperative patients recovering from systemic inflammatory response syndrome [J].
Bien, MY ;
Hseu, SS ;
Yien, HW ;
Kuo, BIT ;
Lin, YT ;
Wang, JH ;
Kou, YR .
INTENSIVE CARE MEDICINE, 2004, 30 (02) :241-247
[7]
Feasibility of continuous multiorgan variability analysis in the intensive care unit [J].
Bradley, Beverly ;
Green, Geoffrey C. ;
Batkin, Izmail ;
Seely, Andrew J. E. .
JOURNAL OF CRITICAL CARE, 2012, 27 (02) :218.e9-218.e20
[8]
Review and classification of variability analysis techniques with clinical applications [J].
Bravi, Andrea ;
Longtin, Andre ;
Seely, Andrew J. E. .
BIOMEDICAL ENGINEERING ONLINE, 2011, 10
[9]
Effect of a nursing-implemented sedation protocol on the duration of mechanical ventilation [J].
Brook, AD ;
Ahrens, TS ;
Schaiff, R ;
Prentice, D ;
Sherman, G ;
Shannon, W ;
Kollef, MH .
CRITICAL CARE MEDICINE, 1999, 27 (12) :2609-2615
[10]
Buchman Timothy G, 2002, Curr Opin Crit Care, V8, P311, DOI 10.1097/00075198-200208000-00007