Separation and preconcentration of inorganic and organomercury species in water samples using a selective reagent and an anion exchange resin and determination by flow injection-cold vapor atomic absorption spectrometry

被引:42
作者
de Wuilloud, JCA
Wuilloud, RG
Olsina, RA
Martinez, LD
机构
[1] Natl Univ San Luis, Fac Chem Biochem & Pharm, Dept Analyt Chem, RA-5700 San Luis, Argentina
[2] Consejo Nacl Invest Cient & Tecn, Buenos Aires, DF, Argentina
关键词
D O I
10.1039/b110853k
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An on-line inorganic (InHg) and organomercury (OrHg) species separation. preconcentration and determination system consisting of cold vapor atomic absorption spectrometry (CV-AAS) coupled to a flow injection (FI) method was studied. The inorganic mercury species was retained on a column (id, 3 mm; length, 80 mm) charged with a Dowex IX-8 resin (particle size 50-100 mesh) as the anionic complex formed with Methylthymol Blue (MTB), at pH 6.3. Previous oxidation of the organomercurial species permitted the determination of total mercury. Therefore, the separation of mercury species was obtained with the combined use of on-line selective formation of the InHg-MTB complex and the retention of this anionic compound on the anion exchange resin. The difference between total and inorganic mercury determined the organomercury content in the samples. The inorganic mercury was removed on-line from the micro-column with 3 M nitric acid. The mercury cold vapor generation was performed in an on-line system with 7.0% (w/v) SnCl2 and 20% (v/v) HCl as reducing solution. A preconcentration factor of 180 was obtained for the preconcentration of 250 ml of aqueous Solution. The detection limit for InHg and OrHg was 0.8 ng l(-1). The precision for ten replicate determinations at the 15 ng l(-1) Hg level was 4.4% relative standard deviation (RSD), calculated from the peak heights obtained. The calibration graph using the separation and preconcentration system for mercury species was linear. with a correlation coefficient of 0.9994 at levels near the detection limit Lip to at least 100 mug l(-1). The accuracy of the method was evaluated by the analysis of a certified reference material QC Metal LL3 Mercury in Water. The method was successfully applied to the speciation of mercury in water samples.
引用
收藏
页码:389 / 394
页数:6
相关论文
共 42 条
[1]  
BARKAY T, 1986, ENCY MICROBIOLOGY, V3
[2]   Determination of methylmercury in natural water samples by steam distillation and gas chromatography atomic fluorescence spectrometry [J].
Bowles, KC ;
Apte, SC .
ANALYTICAL CHEMISTRY, 1998, 70 (02) :395-399
[3]   Determination of methylmercury in sediments by steam distillation/aqueous-phase ethylation and atomic fluorescence spectrometry [J].
Bowles, KC ;
Apte, SC .
ANALYTICA CHIMICA ACTA, 2000, 419 (02) :145-151
[4]   Kinetics and mechanism of complex formation between Mg2+ and methylthymol blue [J].
Bremer, C ;
Ruf, H ;
Grell, E .
JOURNAL OF PHYSICAL CHEMISTRY A, 1998, 102 (01) :146-152
[5]   The use of emulsions for the determination of methylmercury and inorganic mercury in fish-eggs oil by cold vapor generation in a flow injection system with atomic absorption spectrometric detection [J].
Burguera, JL ;
Quintana, IA ;
Salager, JL ;
Burguera, M ;
Rondón, C ;
Carrero, P ;
de Salager, RA ;
de Peña, YP .
ANALYST, 1999, 124 (04) :593-599
[6]   Determination of organomercury compounds in aqueous samples by capillary gas chromatography atomic fluorescence spectrometry following solid-phase extraction [J].
Cai, Y ;
Jaffe, R ;
Alli, A ;
Jones, RD .
ANALYTICA CHIMICA ACTA, 1996, 334 (03) :251-259
[7]  
Campos RC, 1997, ATOM SPECTROSC, V18, P55
[8]   Selectivity enhancement in spectrophotometry: on-line interference suppression using polyurethane foam minicolumn for aluminum determination with Methyl Thymol Blue [J].
Cassella, RJ ;
Santelli, RE ;
Branco, AG ;
Lemos, VA ;
Ferreira, SLC ;
de Carvalho, MS .
ANALYST, 1999, 124 (05) :805-808
[9]   Integrated sample preparation and speciation analysis for the simultaneous determination of methylated species of tin, lead and mercury in water by purge-and-trap injection-capillary gas chromatography atomic emission spectrometry [J].
Ceulemans, M ;
Adams, FC .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1996, 11 (03) :201-206
[10]  
CHENG KL, 1982, HDB ORGANIC ANAL REA