Selectivity enhancement in spectrophotometry: on-line interference suppression using polyurethane foam minicolumn for aluminum determination with Methyl Thymol Blue

被引:41
作者
Cassella, RJ [1 ]
Santelli, RE
Branco, AG
Lemos, VA
Ferreira, SLC
de Carvalho, MS
机构
[1] Univ Fed Fluminense, Dept Geoquim, BR-24020007 Niteroi, RJ, Brazil
[2] Univ Fed Bahia, Inst Quim, BR-40170290 Salvador, BA, Brazil
[3] CNEN, Inst Engn Nucl, Rio De Janeiro, Brazil
关键词
D O I
10.1039/a900778d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A method is proposed for the determination of aluminum by flow injection spectrophotometry with Methyl Thymol Blue after separation of the interferent ions employing a polyurethane foam (PUF) minicolumn. The separation process is based on the retention of the interferents on the PUF minicolumn as thiocyanate complexes. In order to improve the performance of the system the effect of some chemical and flow variables were evaluated and under optimized conditions the system was able to determine aluminum at a concentration of 1.0 mu g mL(-1) in the presence of Fe(III) at 170 mu g mL(-1), Zn(II) at 100 mu g mL(-1) and Cu(II) and Co(II) at 50 mu g mL(-1), using a PUF minicolumn containing 200 mg of sorbent. The analytical procedure developed was successfully applied to several certified materials, including silicate materials and ores. Very good accuracy and precision was obtained. A limit of detection of 30 ng mL(-1) was achieved with RSD of 4.5% at 0.25 mu g mL(-1). A linear dynamic range from 0.25-2.0 mu g mL(-1) was observed and a sample frequency of 17 samples per hour was calculated.
引用
收藏
页码:805 / 808
页数:4
相关论文
共 16 条
[1]   COLUMN SOLID-PHASE EXTRACTION AS PRECONCENTRATION METHOD FOR TRACE-ELEMENT DETERMINATION IN OXALIC-ACID BY ATOMIC-ABSORPTION SPECTROMETRY AND INDUCTIVELY-COUPLED PLASMA-ATOMIC EMISSION-SPECTROMETRY [J].
ALEXANDROVA, A ;
ARPADJAN, S .
ANALYTICA CHIMICA ACTA, 1995, 307 (01) :71-77
[2]  
BAI YW, 1994, FENXI HUAXUE, V22, P916
[3]   Luminescence determination of europium microquantities after its preconcentration on polyurethane foam [J].
Beltyukova, S ;
Balamtsarashvili, C .
TALANTA, 1995, 42 (12) :1833-1838
[4]   SORPTION OF YTTRIUM HYDROXYQUINOLINATES BY POLYURETHANE FOAM AND ITS USE IN ROCK ANALYSIS [J].
BELTYUKOVA, SV ;
NAZARENKO, NA ;
TSYGANKOVA, S .
ANALYST, 1995, 120 (06) :1693-1698
[5]  
Braun T., 1985, POLYURETHANE FOAM SO
[6]   Polyurethane foam as a sorbent for continuous flow analysis: Preconcentration and spectrophotometric determination of zinc in biological materials [J].
de Jesus, DS ;
Casella, RJ ;
Ferreira, SLC ;
Costa, ACS ;
de Carvalho, MS ;
Santelli, RE .
ANALYTICA CHIMICA ACTA, 1998, 366 (1-3) :263-269
[7]   Detection and semiquantitative determination of bismuth(III) in water on immobilized and plasticized polyurethane foams with some chromogenic reagents [J].
ElShahawi, MS ;
AlMehrezi, RS .
TALANTA, 1997, 44 (03) :483-489
[8]  
Fang, 1995, FLOW INJECTION SEPAR
[9]   Spectrophotometric determination of aluminium in iron ores using solid-phase extraction [J].
Ferreira, SLC ;
Lemos, VA ;
Celso, A ;
Costa, S ;
de Jesus, DS ;
de Carvalho, MS .
JOURNAL OF THE BRAZILIAN CHEMICAL SOCIETY, 1998, 9 (02) :151-156
[10]   An on-line solid phase extraction system using polyurethane foam for the spectrophotometric determination of nickel in silicates and alloys [J].
Ferreira, SLC ;
de Jesus, DS ;
Cassella, RJ ;
Costa, ACS ;
de Carvalho, MS ;
Santelli, RE .
ANALYTICA CHIMICA ACTA, 1999, 378 (1-3) :287-292