Leucocyte filtration during cardiopulmonary bypass hardly changed leucocyte counts and did not influence myeloperoxidase, complement, cytokines or platelets

被引:21
作者
Baksaas, S. T. [1 ]
Videm, V. [2 ,3 ]
Mollnes, T. E. [4 ]
Tollofsrud, S. [1 ]
Hetland, G. [5 ]
Pedersen, T. [1 ]
Svennevig, J. L. [1 ]
机构
[1] Univ Oslo, Natl Hosp, Dept Surg A, N-0027 Oslo, Norway
[2] Norwegian Univ Sci & Technol, Reg Hosp, Dept Immunol, N-7034 Trondheim, Norway
[3] Norwegian Univ Sci & Technol, Reg Hosp, Blood Bank, N-7034 Trondheim, Norway
[4] Univ Tromso, Nordland Cent Hosp, Dept Immunol & Transfus Med, N-9001 Tromso, Norway
[5] Univ Oslo, Inst Gen & Rheumatol Immunol, N-0027 Oslo, Norway
来源
PERFUSION-UK | 1998年 / 13卷 / 06期
关键词
D O I
10.1177/026765919801300606
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
In some patients, coronary artery bypass surgery induces postoperative organ dysfunction despite an apparently adequate revascularization and good haemodynamic performance. This complication may be caused by activation of the body's inflammatory systems on blood contact with large foreign surfaces in the extracorporeal circuit. Activated leucocytes may play an important role in organ damage, and it is conceivable that leucocyte removal by filtration may decrease the potential side-effects of cardiopulmonary bypass (CPB). The aim of the present study was to investigate possible effects of leucocyte filtration during the whole CPB period in elective coronary artery bypass surgery on biochemical and clinical parameters. Forty patients were randomized to extracorporeal circulation using a leucocyte-depleting filter (group L, n = 20) or to extracorporeal circulation with no leucocyte filter (group C, n = 20). In the leucocyte-depleted group, the mean total white blood cell counts increased from 6.3 (95% confidence interval, 5.5 - 7.0) x 10(9)/l to 7.0 (5.7 - 8.3) x 10(9)/l during extracorporeal circulation and in the control group from 6.3 (5.2 - 7.3) x 10(9)/l to 8.5 (7.2 -9.8) x 10(9)/l. The intergroup difference was not statistically significant (p = 0.84). A substantial increase in concentrations of interleukin-6, myeloperoxidase and complement activation products were observed in both groups without statistically significant intergroup differences. It is concluded that the leucocyte-depletion filter did not cause a significant reduction of circulating white blood cells during CPB, and there were no significant differences between the groups with respect to the inflammatory markers studied.
引用
收藏
页码:429 / 436
页数:8
相关论文
共 27 条
[11]   Leukocyte depletion results in improved lung function and reduced inflammatory response after cardiac surgery [J].
Gu, YJ ;
deVries, AJ ;
Boonstra, PW ;
vanOeveren, W .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1996, 112 (02) :494-500
[12]  
JANSEN NJG, 1991, J THORAC CARDIOV SUR, V102, P515
[13]   NEUTROPHIL-MEDIATED ACUTE LUNG INJURY AFTER EXTRACORPOREAL PERFUSION [J].
JOHNSON, D ;
THOMSON, D ;
HURST, T ;
PRASAD, K ;
WILSON, T ;
MURPHY, F ;
SAXENA, A ;
MAYERS, I .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1994, 107 (05) :1193-1202
[14]  
KILGORE KS, 1995, J IMMUNOL, V155, P1434
[15]  
Kirklin JK, 1989, CARDIOPULMONARY BYPA, P131
[16]   THE INFLUENCE OF LEUKOCYTE FILTRATION DURING CARDIOPULMONARY BYPASS ON POSTOPERATIVE LUNG-FUNCTION - A CLINICAL-STUDY [J].
MIHALJEVIC, T ;
TONZ, M ;
VONSEGESSER, LK ;
PASIC, M ;
GROB, P ;
FEHR, J ;
SEIFERT, B ;
TURINA, M .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1995, 109 (06) :1138-1145
[17]   QUANTIFICATION OF THE TERMINAL COMPLEMENT COMPLEX IN HUMAN-PLASMA BY AN ENZYME-LINKED IMMUNOSORBENT-ASSAY BASED ON MONOCLONAL-ANTIBODIES AGAINST A NEOANTIGEN OF THE COMPLEX [J].
MOLLNES, TE ;
LEA, T ;
FROLAND, SS ;
HARBOE, M .
SCANDINAVIAN JOURNAL OF IMMUNOLOGY, 1985, 22 (02) :197-202
[18]   OXIDATIVE REGULATION OF NEUTROPHIL ELASTASE ALPHA-1-PROTEINASE INHIBITOR INTERACTIONS [J].
OSSANNA, PJ ;
TEST, ST ;
MATHESON, NR ;
REGIANI, S ;
WEISS, SJ .
JOURNAL OF CLINICAL INVESTIGATION, 1986, 77 (06) :1939-1951
[19]  
Palanzo David A., 1993, Perfusion, V8, P489, DOI 10.1177/026765919300800608
[20]  