Net analyte preprocessing: a new and versatile multivariate calibration technique. Analysis of mixtures of rubber antioxidants by NIR spectroscopy

被引:17
作者
Boschetti, CE
Olivieri, AC
机构
[1] Univ Nacl Rosario, Fac Ciencias Bioquim & Farmaceut, Dept Quim Analit, RA-2000 Rosario, Santa Fe, Argentina
[2] Pecom Energia SA, Planta PGSM, Lab Certificac Calidad, Puerto Gen San Martin, Argentina
关键词
net analyte preprocessing; rubber antioxidants; tris-(nonylphenyl)-phosphite; 4,6-bis-(octylthiomethyl)-o-cresol;
D O I
10.1255/jnirs.310
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
A new multivariate calibration technique called net analyte preprocessing is introduced for the study of mixtures by near infrared spectroscopy. It involves the construction of a space spanned by all sources of variability except one component (or reference property). Both the data matrix and the unknown sample spectrum are preprocessed through a projection orthogonal to the latter space, yielding a set of net analyte signals appropriate for quantifying a particular mixture component. The construction of the net analyte space is carried out using a certain number of spectral factors, which can be estimated by cross-validation. Advantages of the presently discussed method include the estimation of figures of merit (sensitivity, selectivity and limit of determination) and the presentation of data in a useful pseudounivariate mode. An example involving the successful analysis of mixtures of the two rubber antioxidants tris-(nonylphenyl)-phosphite and 4,6-bis-(octylthiomethyl)-o-cresol is described, and compared with classical techniques such as principal component regression and partial least-squares.
引用
收藏
页码:245 / 254
页数:10
相关论文
共 24 条
[11]   MULTIVAR. A program for multivariate calibration incorporating net analyte signal calculations [J].
Goicoechea, HC ;
Olivieri, AC .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2000, 19 (10) :599-605
[12]   A comparison of orthogonal signal correction and net analyte preprocessing methods. Theoretical and experimental study [J].
Goicoechea, HC ;
Olivieri, AC .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2001, 56 (02) :73-81
[13]   Enhanced synchronous spectrofluorometric determination of tetracycline in blood serum by chemometric analysis. Comparison of partial least-squares and hybrid linear analysis calibrations [J].
Goicoechea, HC ;
Olivieri, AC .
ANALYTICAL CHEMISTRY, 1999, 71 (19) :4361-4368
[14]   Intra-laboratory testing of method accuracy from recovery assays [J].
González, AG ;
Herrador, MA ;
Asuero, AG .
TALANTA, 1999, 48 (03) :729-736
[15]   PARTIAL LEAST-SQUARES METHODS FOR SPECTRAL ANALYSES .1. RELATION TO OTHER QUANTITATIVE CALIBRATION METHODS AND THE EXTRACTION OF QUALITATIVE INFORMATION [J].
HAALAND, DM ;
THOMAS, EV .
ANALYTICAL CHEMISTRY, 1988, 60 (11) :1193-1202
[16]   Net analyte signal calculation in multivariate calibration [J].
Lorber, A ;
Faber, K ;
Kowalski, BR .
ANALYTICAL CHEMISTRY, 1997, 69 (08) :1620-1626
[17]   ERROR PROPAGATION AND FIGURES OF MERIT FOR QUANTIFICATION BY SOLVING MATRIX EQUATIONS [J].
LORBER, A .
ANALYTICAL CHEMISTRY, 1986, 58 (06) :1167-1172
[18]  
LUSSIER FE, 1983, RUBBER WORLD, V188, P18
[19]  
MARK H, 1963, KIRK OTHMER ENCY CHE, V2
[20]  
*MATH WORKS INC, 1999, MATL VERS 5 3