Determination of phenols in water samples by single-drop microextraction followed by in-syringe derivatization and gas chromatography-mass spectrometric detection

被引:117
作者
Saraji, M [1 ]
Bakhshi, M [1 ]
机构
[1] Isfahan Univ Technol, Dept Chem, Esfahan 84156, Iran
关键词
single-drop microextraction; derivatization; environmental analysis; phenols;
D O I
10.1016/j.chroma.2005.08.063
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Trace analysis of phenolic compounds in water was performed by coupling single-drop microextraction (SDME) with in-syringe derivatization of the analytes and GC-MS analysis. The analytes were extracted from a 3 nil sample solution using 2.5 mu l of hexyl acetate. After extraction, derivatization was carried out in syringe barrel using 0.5 d of N,O-bis(trimethylsilyl)acetamide. The influence of derivatizing reagent volume, derivatization time and temperature on the yield of the in-syringe silylation was investigated. Derivatization reaction is completed in 5 min at 50 degrees C. Experimental SDME parameters, such as selection of organic solvent, sample pH, addition of salt, extraction time and temperature of extraction were studied. Analytical parameters, such as enrichment factor, precision, linearity and detection limits were also determined. The limits of detection were in the range of 4-61 ng/l (S/N = 3). The relative standard deviations obtained were between 4,8 and 12% (n = 5). (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:30 / 36
页数:7
相关论文
共 37 条
[1]   Monitoring of priority pesticides and other organic pollutants in river water from Portugal by gas chromatography-mass spectrometry and liquid chromatography-atmospheric pressure chemical ionization mass spectrometry [J].
Azevedo, DD ;
Lacorte, S ;
Vinhas, T ;
Viana, P ;
Barceló, D .
JOURNAL OF CHROMATOGRAPHY A, 2000, 879 (01) :13-26
[2]   An electropolymerized aniline-based fiber coating for solid phase microextraction of phenols from water [J].
Bagheri, H ;
Mir, A ;
Babanezhad, E .
ANALYTICA CHIMICA ACTA, 2005, 532 (01) :89-95
[3]   Immersed solvent microextraction of phenol and chlorophenols from water samples followed by gas chromatography-mass spectrometry [J].
Bagheri, H ;
Saber, A ;
Mousavi, SR .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1046 (1-2) :27-33
[4]   Conductive polymers as new media for solid-phase extraction: Isolation of chlorophenols from water sample [J].
Bagheri, H ;
Saraji, M .
JOURNAL OF CHROMATOGRAPHY A, 2003, 986 (01) :111-119
[5]  
Baltussen E, 1999, J MICROCOLUMN SEP, V11, P471, DOI 10.1002/(SICI)1520-667X(1999)11:6<471::AID-MCS9>3.0.CO
[6]  
2-9
[7]   Determination of phenols by solid-phase microextraction [J].
Bartak, P ;
Cap, L .
JOURNAL OF CHROMATOGRAPHY A, 1997, 767 (1-2) :171-175
[8]   Comparison of three derivatization ways in the separation of phenol and hydroquinone from water samples [J].
Bielicka-Daszkiewicz, K ;
Debicka, M ;
Voelkel, A .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1052 (1-2) :233-236
[9]  
Blanchard F, 2003, J NEW MAT ELECTR SYS, V6, P245
[10]   IDENTIFICATION AND QUANTIFICATION OF MONOHYDROXYBENZENES, DIHYDROXYBENZENES AND TRIHYDROXYBENZENES (PHENOLS) AT TRACE CONCENTRATIONS IN SEAWATER BY AQUEOUS ACETYLATION AND GAS-CHROMATOGRAPHIC MASS-SPECTROMETRIC ANALYSIS [J].
BOYD, TJ .