High-performance high-Tc SQUID sensors for multichannel systems in magnetically disturbed environment

被引:10
作者
Ludwig, F [1 ]
Beyer, J [1 ]
Drung, D [1 ]
Bechstein, S [1 ]
Schurig, T [1 ]
机构
[1] Phys Tech Bundesanstalt, Inst Berlin, D-10587 Berlin, Germany
关键词
D O I
10.1109/77.783853
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We have fabricated and characterized high-T-c SQUID sensors that are suited for operation in multichannel systems in magnetically disturbed environment. Utilizing the superior properties of our 30 degrees SrTiO3 bicrystal junctions, we are able to fabricate high-performance single layer direct-coupled SQUID magnetometers. System noise levels down to 24 ft Hz(-1/2) and typical 1/f corners of 4 Hz were obtained for devices having a 9 mm x 9 mm pickup loop and a nominal SQUID inductance of 100 pH. To protect the SQUIDs from moisture, they are hermetically encapsulated in a ceramic housing. A thick film resistor integrated on the chip carrier allows one to heat the SQUID device above T-c in order to release trapped magnetic flux. For the operation of our low-noise SQUIDs, a compact direct-coupled read-out electronics with a preamplifier voltage noise of 0.4 nV Hz(-1/2) and 100 kHz bias reversal was developed. Sensor dynamics and linearity were investigated with regard to the operation in magnetically disturbed environment. The maximum system bandwidth and slew rate of our bias reversal electronics were 1 MHz and about 5 x 10(5) Phi(0)/s, respectively. For signal frequencies less than or equal to 50 Hz, a minimum total harmonic distortion of -118 dB was measured, dominated by nonlinearities in the read-out electronics. A new magnetometer design with improved noise performance in magnetically disturbed environment is presented.
引用
收藏
页码:3793 / 3796
页数:4
相关论文
共 13 条
[1]   Low-noise YBa2Cu3O7-x single layer dc superconducting quantum interference device (SQUID) magnetometer based on bicrystal junctions with 30° misorientation angle [J].
Beyer, J ;
Drung, D ;
Ludwig, F ;
Minotani, T ;
Enpuku, K .
APPLIED PHYSICS LETTERS, 1998, 72 (02) :203-205
[2]  
BEYER J, UNPUB J APPL PHYS
[3]   Electronic high-temperature radio frequency superconducting quantum interference device gradiometers for unshielded environment [J].
Borgmann, J ;
David, P ;
Ockenfuss, G ;
Otto, R ;
Schubert, J ;
Zander, W ;
Braginski, AI .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1997, 68 (07) :2730-2734
[4]  
BRAGINSKI AI, 1997, 6 INT SUP EL C ISEC, V1, P121
[5]   Reduction of 1/f noise in high-T-c dc superconducting quantum interference devices cooled in an ambient magnetic field [J].
Dantsker, E ;
Tanaka, S ;
Nilsson, PA ;
Kleiner, R ;
Clarke, J .
APPLIED PHYSICS LETTERS, 1996, 69 (26) :4099-4101
[6]  
Drung D, 1996, NATO ADV SCI I E-APP, V329, P63
[7]   Improved dc SQUID read-out electronics with low 1/f noise preamplifier [J].
Drung, D .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1997, 68 (11) :4066-4074
[8]   FLUX DAM, A METHOD TO REDUCE EXTRA LOW-FREQUENCY NOISE WHEN A SUPERCONDUCTING MAGNETOMETER IS EXPOSED TO A MAGNETIC-FIELD [J].
KOCH, RH ;
SUN, JZ ;
Foglietti, V ;
GALLAGHER, WJ .
APPLIED PHYSICS LETTERS, 1995, 67 (05) :709-711
[9]   LOW-NOISE YBA2CU3O7-DELTA DIRECT-CURRENT SUPERCONDUCTING QUANTUM INTERFERENCE DEVICE MAGNETOMETER WITH DIRECT SIGNAL INJECTION [J].
LEE, LP ;
LONGO, J ;
VINETSKIY, V ;
CANTOR, R .
APPLIED PHYSICS LETTERS, 1995, 66 (12) :1539-1541
[10]   YBa2Cu3O7-x dc squid magnetometers with bicrystal junctions for biomagnetic multichannel applications [J].
Ludwig, F ;
Beyer, J ;
Drung, D ;
Bechstein, S ;
Schurig, TH .
APPLIED SUPERCONDUCTIVITY, 1997, 5 (7-12) :345-352