Patient size and x-ray technique factors in head computed tomography examinations. I. Radiation doses

被引:70
作者
Huda, W [1 ]
Lieberman, KA [1 ]
Chang, J [1 ]
Roskopf, ML [1 ]
机构
[1] SUNY Upstate Med Univ, Dept Radiol, Syracuse, NY 13210 USA
关键词
MR artifacts; magnetic susceptibility; needle localization; needle visualization; needle tip artifact;
D O I
10.1118/1.1646232
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We investigated how patient age, size and composition, together with the choice of x-ray technique factors, affect radiation doses in head computed tomography (CT) examinations. Head size dimensions, cross-sectional areas, and mean Hounsfield unit (HU) values were obtained from head CT images of 127 patients. For radiation dosimetry purposes patients were modeled as uniform cylinders of water. Dose computations were performed for 18x7 mm sections, scanned at a constant 340 mAs, for x-ray tube voltages ranging from 80 to 140 kV. Values of mean section dose, energy imparted, and effective dose were computed for patients ranging from the newborn to adults. There was a rapid growth of head size over the first two years, followed by a more modest increase of head size until the age of 18 or so. Newborns have a mean HU value of about 50 that monotonically increases with age over the first two decades of life. Average adult A-P and lateral dimensions were 186 8 mm and 147 8 mm, respectively, with an average HU value of 209+/-40. An infant head was found to be equivalent to a water cylinder with a radius of similar to60 mm, whereas an adult head had an equivalent radius 50% greater. Adult males head dimensions are about 5% larger than for females, and their average x-ray attenuation is similar to20 HU greater. For adult examinations performed at 120 kV, typical values were 32 mGy for the mean section dose, 105 mJ for the total energy imparted, and 0.64 mSv for the effective dose. Increasing the x-ray tube voltage from 80 to 140 kV increases patient doses by about a factor of 5. For the same technique factors, mean section doses in infants are 35% higher than in adults. Energy imparted for adults is 50% higher than for infants, but infant effective doses are four times higher than for adults. CT doses need to take into account patient age, head size, and composition as well as the selected x-ray technique factors. (C) 2004 American Association of Physicists in Medicine.
引用
收藏
页码:588 / 594
页数:7
相关论文
共 32 条
[1]  
[Anonymous], 1991, ANN ICRP, V60
[2]  
[Anonymous], 100 NCRP
[3]   Energy imparted and effective doses in computed tomography [J].
Atherton, JV ;
Huda, W .
MEDICAL PHYSICS, 1996, 23 (05) :735-741
[4]   Dose reduction in pediatric CT: A rational approach [J].
Boone, JM ;
Geraghty, EM ;
Seibert, JA ;
Wootton-Gorges, SL .
RADIOLOGY, 2003, 228 (02) :352-360
[5]   Monte Carlo assessment of computed tomography dose to tissue adjacent to the scanned volume [J].
Boone, JM ;
Cooper, VN ;
Nemzek, WR ;
McGahan, JP ;
Seibert, JA .
MEDICAL PHYSICS, 2000, 27 (10) :2393-2407
[6]   Estimated risks of radiation-induced fatal cancer from pediatric CT [J].
Brenner, DJ ;
Elliston, CD ;
Hall, EJ ;
Berdon, WE .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (02) :289-296
[7]   AN ATTEMPT TO STANDARDIZE THE RADIODIAGNOSTIC RISK STATEMENT IN AN INSTITUTIONAL REVIEW BOARD CONSENT FORM [J].
CASTRONOVO, FP .
INVESTIGATIVE RADIOLOGY, 1993, 28 (06) :533-538
[8]   AVERAGE RADIATION-DOSE IN STANDARD CT EXAMINATIONS OF THE HEAD - RESULTS OF THE 1990 NEXT SURVEY [J].
CONWAY, BJ ;
MCCROHAN, JL ;
ANTONSEN, RG ;
RUETER, FG ;
SLAYTON, RJ ;
SULEIMAN, OH .
RADIOLOGY, 1992, 184 (01) :135-140
[9]   Minimizing radiation dose for pediatric body applications of single-detector helical CT: Strategies at a large children's hospital [J].
Donnelly, LF ;
Emery, KH ;
Brody, AS ;
Laor, T ;
Gylys-Morin, VM ;
Anton, CG ;
Thomas, SR ;
Frush, DP .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2001, 176 (02) :303-306
[10]  
Hall E J, 2000, J Radiol Prot, V20, P347, DOI 10.1088/0952-4746/20/4/001