Estimated risks of radiation-induced fatal cancer from pediatric CT

被引:2368
作者
Brenner, DJ
Elliston, CD
Hall, EJ
Berdon, WE
机构
[1] Columbia Univ, Ctr Radiol Res, New York, NY 10032 USA
[2] Columbia Presbyterian Med Ctr, Dept Radiol, Div Pediat Radiol, New York, NY 10032 USA
关键词
D O I
10.2214/ajr.176.2.1760289
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. In light of the rapidly increasing frequency of pediatric CT examinations, the purpose of our study was to assess the lifetime cancer mortality risks attributable to radiation from pediatric CT. MATERIALS AND METHODS. Organ doses as a function of age-at-diagnosis were estimated for common CT examinations, and estimated attributable lifetime cancer mortality risks (per unit dose) for different organ sites were applied. Standard models that assume a linear extrapolation of risks from intermediate to low doses were applied. On the basis of current standard practice, the same exposures (milliampere-seconds) were assumed, independent of age. RESULTS. The larger doses and increased lifetime radiation risks in children produce a sharp increase, relative to adults, in estimated risk from CT. Estimated lifetime cancer mortality risks attributable to the radiation exposure from a CT in a I-year-old are 0.18% (abdominal) and 0.07% (head)-an order of magnitude higher than for adults-although those figures still represent a small increase in cancer mortality over the natrual background rate. In the United States. of approximately 600.000 abdominal and head CT examinations annually per Formed in children under the age of 15 years, a rough estimate is that 500 of these individuals might ultimately die from cancer attributable to the CT radiation. CONCLUSION, The best available risk estimates suggest that pediatric CT will result in significantly increased lifetime radiation risk over adult CT, both because of the increased dose per milliampere-second, and the increased lifetime risk per unit dose. Lower milliampere-second settings can be used for children without significant loss of information. Although the risk-benefit balance is still strongly tilted toward benefit, because the frequency of pediatric CT examinations is rapidly increasing. estimates that quantitative lifetime radiation risks for children undergoing CT are not negligible may stimulate more active reduction of CT exposure settings in pediatric patients.
引用
收藏
页码:289 / 296
页数:8
相关论文
共 46 条
  • [1] FEASIBILITY OF HIGH-RESOLUTION, LOW-DOSE CHEST CT IN EVALUATING THE PEDIATRIC CHEST
    AMBROSINO, MM
    GENIESER, NB
    ROCHE, KJ
    KAUL, A
    LAWRENCE, RM
    [J]. PEDIATRIC RADIOLOGY, 1994, 24 (01) : 6 - 10
  • [2] [Anonymous], 1998, MED PHYS, V25, P273, DOI 10.1118/1.598207
  • [3] [Anonymous], UN PUBL
  • [4] Bahador B, 1996, TRENDS DIAGNOSTIC IM
  • [5] Beir V Committee on the Biological Effects of Ionising Radiation, 1990, HLTH EFF EXP LOW LEV
  • [6] An EGS4-ready tomographic computational model of a 14-year-old female torso for calculating organ doses from CT examinations
    Caon, M
    Bibbo, G
    Pattison, J
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 1999, 44 (09) : 2213 - 2225
  • [7] CHAMBERLAIN C, 1998, MED PHYS, V25, pA216
  • [8] Radiation dose reduction in paediatric cranial CT
    Chan, CY
    Wong, YC
    Chau, LF
    Yu, SK
    Lau, PC
    [J]. PEDIATRIC RADIOLOGY, 1999, 29 (10) : 770 - 775
  • [9] AVERAGE RADIATION-DOSE IN STANDARD CT EXAMINATIONS OF THE HEAD - RESULTS OF THE 1990 NEXT SURVEY
    CONWAY, BJ
    MCCROHAN, JL
    ANTONSEN, RG
    RUETER, FG
    SLAYTON, RJ
    SULEIMAN, OH
    [J]. RADIOLOGY, 1992, 184 (01) : 135 - 140
  • [10] Coren ME, 1998, PEDIATR PULM, V26, P389, DOI 10.1002/(SICI)1099-0496(199812)26:6<389::AID-PPUL3>3.0.CO