Radiation dose reduction in paediatric cranial CT

被引:51
作者
Chan, CY [1 ]
Wong, YC [1 ]
Chau, LF [1 ]
Yu, SK [1 ]
Lau, PC [1 ]
机构
[1] Tuen Mun Hosp, Dept Diagnost Radiol, Hong Kong, Peoples R China
关键词
D O I
10.1007/s002470050692
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Background. There is no consensus about the optimal milliamperage-second (mAs) settings for computed tomography (CT). Most operators follow the recommended settings of the manufacturers, but these may not be the most appropriate settings. Objective. To determine whether a lower radiation dose technique could be used in CT of the paediatric brain without jeopardising the diagnostic accuracy of the images. Materials and methods. A randomised prospective trial. A group of 53 children underwent CT using manufacturer's default levels of 200 or 250 mAs; 47 underwent scanning at 125 or 150 mAs. Anatomical details and the confidence level in reaching a diagnosis were evaluated by two radiologists in a double-blinded manner using a Lt-point scoring system. Results. For both readers there was no statistically significant difference in the confidence level for reaching a diagnosis between the two groups. The 95 % confidence intervals and P values were -0.9-1.1 and 0.13 treader 1) and -1.29-1.37 and 0.70 treader 2), respectively. Reliability tests showed the results were consistent. Conclusions. The recommended level may not be the optimum setting. Dose reduction of 40 % is possible on our system in paediatric brain CT without affecting the diagnostic quality of the images.
引用
收藏
页码:770 / 775
页数:6
相关论文
共 15 条
  • [1] [Anonymous], 1991, PRACTICAL STAT MED R
  • [2] DIAGNOSTIC-X-RAY PROCEDURES AND RISK OF LEUKEMIA, LYMPHOMA, AND MULTIPLE-MYELOMA
    BOICE, JD
    MORIN, MM
    GLASS, AG
    FRIEDMAN, GD
    STOVALL, M
    HOOVER, RN
    FRAUMENI, JF
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1991, 265 (10): : 1290 - 1294
  • [3] AVERAGE RADIATION-DOSE IN STANDARD CT EXAMINATIONS OF THE HEAD - RESULTS OF THE 1990 NEXT SURVEY
    CONWAY, BJ
    MCCROHAN, JL
    ANTONSEN, RG
    RUETER, FG
    SLAYTON, RJ
    SULEIMAN, OH
    [J]. RADIOLOGY, 1992, 184 (01) : 135 - 140
  • [4] HAZARDS OF IONIZING-RADIATION - 100 YEARS OF OBSERVATIONS ON MAN
    DOLL, R
    [J]. BRITISH JOURNAL OF CANCER, 1995, 72 (06) : 1339 - 1349
  • [5] Etzel RA, 1998, PEDIATRICS, V101, P717
  • [6] PEDIATRIC-PATIENT EXPOSURES FROM CT EXAMINATIONS - GE CT/T 9800 SCANNER
    FEARON, T
    VUCICH, J
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1985, 144 (04) : 805 - 809
  • [7] NORMALIZED PEDIATRIC ORGAN-ABSORBED DOSES FROM CT EXAMINATIONS
    FEARON, T
    VUCICH, J
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1987, 148 (01) : 171 - 174
  • [8] THE EFFECT OF MAS VARIATION UPON COMPUTED-TOMOGRAPHY IMAGE QUALITY AS EVALUATED BY INVIVO AND INVITRO STUDIES
    HAAGA, JR
    MIRALDI, F
    MACINTYRE, W
    LIPUMA, JP
    BRYAN, PJ
    WIESEN, E
    [J]. RADIOLOGY, 1981, 138 (02) : 449 - 454
  • [9] AVERAGE RADIATION-DOSES IN A STANDARD HEAD EXAMINATION FOR 250-CT SYSTEMS
    MCCROHAN, JL
    PATTERSON, JF
    GAGNE, RM
    GOLDSTEIN, HA
    [J]. RADIOLOGY, 1987, 163 (01) : 263 - 268
  • [10] *PICK INT, 1997, COMP TOM SER OP GUID, V5, P5