A flexible polymer tube lab-chip integrated with microsensors for smart microcatheter

被引:54
作者
Li, Chunyan [1 ]
Wu, Pei-Ming [1 ]
Han, Jungyoup [1 ]
Ahn, Chong H. [1 ]
机构
[1] Univ Cincinnati, Dept Elect & Comp Engn, Microsyst & BioMEMS Lab, Cincinnati, OH 45221 USA
关键词
flexible polymer tube lab-chip; microcatheter; glucose biosensor; flow sensor; temperature sensor;
D O I
10.1007/s10544-008-9178-3
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A flexible polymer tube lab-chip integrated with physical and biochemical sensor modules mounted on a flexible spiral structure for measuring physiological (temperature/ flow rate) and metabolic data (glucose concentration) in a catheter application was designed, fabricated and characterized in this work. This new approach not only provides a unique way to assemble multiple sensors on both the inside and outside the flexible polymer tube using standard microfabrication methods while avoiding wiring and assembling problems associated with previous methods, but also maintains catheter inherent lumen potency for in situ drug delivery or insertion of medical tools. Three well-known sensors: temperature sensor (RTD), flow rate sensor (hot film anemometry) and glucose biosensor (amperometric sensor) have been successfully fabricated and fully integrated outside the spirally rolled polymer tube (ID= 500 mu m, OD= 650 mu m) of this demonstration device. The fabricated sensors showed good performances not only in a planar configuration but also in a spirally rolled configuration. This flexible micro tube lab-chip system provides a generic platform for developing patient-specific "smart" microcatheters that incorporate microsensors, microactuators, microfluidic devices and wireless signal communication modules that are tailored for the patients' unique condition.
引用
收藏
页码:671 / 679
页数:9
相关论文
共 21 条
[1]  
French P., 2003, SENSORS UPDATE, V13, P107, DOI DOI 10.1002/SEUP.200390018
[2]   A fully integrated biosensor array for measurement of metabolic parameters in human blood [J].
Gao, C ;
Choi, JW ;
Dutta, M ;
Chilukuru, S ;
Nevin, JH ;
Lee, JY ;
Bissell, MG ;
Ahn, CH .
2ND ANNUAL INTERNATIONAL IEEE-EMBS SPECIAL TOPIC CONFERENCE ON MICROTECHNOLOGIES IN MEDICINE & BIOLOGY, PROCEEDINGS, 2002, :223-226
[3]  
GAO C, 2003, P MICR TOT AN SYST 2, P797
[4]  
Goosen J. F. L., 2000, Proceedings IEEE Thirteenth Annual International Conference on Micro Electro Mechanical Systems (Cat. No.00CH36308), P537, DOI 10.1109/MEMSYS.2000.838574
[5]   Design considerations for silicon sensors for use in catheters and guide wires [J].
Goosen, JFL .
SMART MATERIALS & STRUCTURES, 2002, 11 (05) :804-812
[6]  
Goosen JFL, 1999, P SOC PHOTO-OPT INS, V3876, P38, DOI 10.1117/12.360501
[7]  
GOOSEN JFL, 1999, P SMIT CIMIT BOST US
[8]   Biomedical microsystems for minimally invasive diagnosis and treatment [J].
Haga, Y ;
Esashi, M .
PROCEEDINGS OF THE IEEE, 2004, 92 (01) :98-114
[9]   A serpentine laminating micromixer combining splitting/recombination and advection [J].
Kim, DS ;
Lee, SH ;
Kwon, TH ;
Ahn, CH .
LAB ON A CHIP, 2005, 5 (07) :739-747
[10]   A flexible and wearable glucose sensor based on functional polymers with Soft-MEMS techniques [J].
Kudo, Hiroyuki ;
Sawada, Takanori ;
Kazawa, Elito ;
Yoshida, Hiromichi ;
Iwasaki, Yasuhiko ;
Mitsubayashi, Kohji .
BIOSENSORS & BIOELECTRONICS, 2006, 22 (04) :558-562